Amperometric aptasensor with sandwich-type architecture for troponin I based on carboxyethylsilanetriol-modified graphene oxide coated electrodes
dc.contributor.author | Villalonga, Anabel | |
dc.contributor.author | Estabiel, Itziar | |
dc.contributor.author | Pérez-Calabuig, Ana | |
dc.contributor.author | Mayol Hornero, Beatriz | |
dc.contributor.author | Parrado Quintela, Concepción | |
dc.contributor.author | Villalonga Santana, Reynaldo | |
dc.date.accessioned | 2024-02-05T15:28:53Z | |
dc.date.available | 2024-02-05T15:28:53Z | |
dc.date.issued | 2021 | |
dc.description.abstract | A novel amperometric aptasensor for the specific detection of cardiac troponin I (cTnI) was constructed by using screen-printed carbon electrodes coated with a carboxyethylsilanetriol-modified graphene oxide derivative as transduction element. This novel carboxylic acid-enriched nanomaterial allows easy and high load immobilization of the capture aptamer molecules on the electrode surface. The biosensing interface was assembled by covalent attachment of an amino-functionalized DNA aptamer on the carboxylic acid-enriched electrode surface. The sensing approach relies on the specific recognition of cTnI by the aptamer and further assembly of a sandwich-type architecture with a novel aptamer-peroxidase conjugate as signaling element. The aptasensor was employed to detect the cardiac biomarker in the broad range from 1.0 pg/mL to 1.0 μg/mL with a detection limit of 0.6 pg/mL. This electroanalytical device also showed high specificity, reproducibility and stability, and was useful to quantify cTnI in reconstituted human serum samples. | |
dc.description.department | Depto. de Química Analítica | |
dc.description.faculty | Fac. de Ciencias Químicas | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Ministerio de Economía y Competitividad (España) | |
dc.description.sponsorship | Comunidad de Madrid | |
dc.description.status | pub | |
dc.identifier.citation | Villalonga, A., Estabiel, I., Pérez-Calabuig, A. M., Mayol, B., Parrado, C., Villalonga, R. (2021). Amperometric aptasensor with sandwich-type architecture for troponin I based on carboxyethylsilanetriol-modified graphene oxide coated electrodes. Biosensors and Bioelectronics 183: 113203. | |
dc.identifier.doi | 10.1016/j.bios.2021.113203 | |
dc.identifier.issn | 0956-5663 | |
dc.identifier.officialurl | https://doi.org/10.1016/j.bios.2021.113203 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/99067 | |
dc.journal.title | Biosensors and Bioelectronics | |
dc.language.iso | eng | |
dc.page.initial | 113203 | |
dc.publisher | Elsevier B.V. | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | en |
dc.rights.accessRights | restricted access | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject.cdu | 543 | |
dc.subject.keyword | Biosensor | |
dc.subject.keyword | Cardiac troponin I | |
dc.subject.keyword | Screen-printed electrode | |
dc.subject.keyword | Graphene | |
dc.subject.keyword | Aptamer | |
dc.subject.ucm | Química analítica (Química) | |
dc.subject.unesco | 2301 Química Analítica | |
dc.title | Amperometric aptasensor with sandwich-type architecture for troponin I based on carboxyethylsilanetriol-modified graphene oxide coated electrodes | |
dc.type | journal article | |
dc.type.hasVersion | VoR | |
dc.volume.number | 183 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | daf14925-b516-40ba-be26-0fda0c21b583 | |
relation.isAuthorOfPublication | 536e974d-3adf-4cc5-a86e-f4967b1abd11 | |
relation.isAuthorOfPublication | a681d857-88a1-4eb9-ab7d-c411c59b3f80 | |
relation.isAuthorOfPublication.latestForDiscovery | a681d857-88a1-4eb9-ab7d-c411c59b3f80 |
Download
Original bundle
1 - 1 of 1