Amperometric aptasensor with sandwich-type architecture for troponin I based on carboxyethylsilanetriol-modified graphene oxide coated electrodes

dc.contributor.authorVillalonga, Anabel
dc.contributor.authorEstabiel, Itziar
dc.contributor.authorPérez-Calabuig, Ana
dc.contributor.authorMayol Hornero, Beatriz
dc.contributor.authorParrado Quintela, Concepción
dc.contributor.authorVillalonga Santana, Reynaldo
dc.date.accessioned2024-02-05T15:28:53Z
dc.date.available2024-02-05T15:28:53Z
dc.date.issued2021
dc.description.abstractA novel amperometric aptasensor for the specific detection of cardiac troponin I (cTnI) was constructed by using screen-printed carbon electrodes coated with a carboxyethylsilanetriol-modified graphene oxide derivative as transduction element. This novel carboxylic acid-enriched nanomaterial allows easy and high load immobilization of the capture aptamer molecules on the electrode surface. The biosensing interface was assembled by covalent attachment of an amino-functionalized DNA aptamer on the carboxylic acid-enriched electrode surface. The sensing approach relies on the specific recognition of cTnI by the aptamer and further assembly of a sandwich-type architecture with a novel aptamer-peroxidase conjugate as signaling element. The aptasensor was employed to detect the cardiac biomarker in the broad range from 1.0 pg/mL to 1.0 μg/mL with a detection limit of 0.6 pg/mL. This electroanalytical device also showed high specificity, reproducibility and stability, and was useful to quantify cTnI in reconstituted human serum samples.
dc.description.departmentDepto. de Química Analítica
dc.description.facultyFac. de Ciencias Químicas
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad (España)
dc.description.sponsorshipComunidad de Madrid
dc.description.statuspub
dc.identifier.citationVillalonga, A., Estabiel, I., Pérez-Calabuig, A. M., Mayol, B., Parrado, C., Villalonga, R. (2021). Amperometric aptasensor with sandwich-type architecture for troponin I based on carboxyethylsilanetriol-modified graphene oxide coated electrodes. Biosensors and Bioelectronics 183: 113203.
dc.identifier.doi10.1016/j.bios.2021.113203
dc.identifier.issn0956-5663
dc.identifier.officialurlhttps://doi.org/10.1016/j.bios.2021.113203
dc.identifier.urihttps://hdl.handle.net/20.500.14352/99067
dc.journal.titleBiosensors and Bioelectronics
dc.language.isoeng
dc.page.initial113203
dc.publisherElsevier B.V.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsrestricted access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu543
dc.subject.keywordBiosensor
dc.subject.keywordCardiac troponin I
dc.subject.keywordScreen-printed electrode
dc.subject.keywordGraphene
dc.subject.keywordAptamer
dc.subject.ucmQuímica analítica (Química)
dc.subject.unesco2301 Química Analítica
dc.titleAmperometric aptasensor with sandwich-type architecture for troponin I based on carboxyethylsilanetriol-modified graphene oxide coated electrodes
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number183
dspace.entity.typePublication
relation.isAuthorOfPublicationdaf14925-b516-40ba-be26-0fda0c21b583
relation.isAuthorOfPublication536e974d-3adf-4cc5-a86e-f4967b1abd11
relation.isAuthorOfPublicationa681d857-88a1-4eb9-ab7d-c411c59b3f80
relation.isAuthorOfPublication.latestForDiscoverya681d857-88a1-4eb9-ab7d-c411c59b3f80

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Amperometric_aptasensor.pdf
Size:
3.3 MB
Format:
Adobe Portable Document Format

Collections