Para depositar en Docta Complutense, identifícate con tu correo @ucm.es en el SSO institucional. Haz clic en el desplegable de INICIO DE SESIÓN situado en la parte superior derecha de la pantalla. Introduce tu correo electrónico y tu contraseña de la UCM y haz clic en el botón MI CUENTA UCM, no autenticación con contraseña.

Efecto del uso de lágrimas artificiales sobre la película lagrimal y la conjuntiva para diferentes requerimientos de fijación, en adultos jóvenes y sanos

dc.contributor.advisorSánchez Ramos, Celia
dc.contributor.advisorBonnin Arias, Cristina Natalia
dc.contributor.advisorBlázquez Sánchez, Vanesa
dc.contributor.authorRojas Yepes, Jairo Giovanni
dc.date.accessioned2025-04-01T11:54:03Z
dc.date.available2025-04-01T11:54:03Z
dc.date.defense2024-10-14
dc.date.issued2025-04-01
dc.descriptionTesis inédita de la Universidad Complutense de Madrid, Facultad de Óptica y Optometría, leída el 14/10/2024
dc.description.abstractObjetivo: evaluar las características de la superficie ocular en un grupo de adultos jóvenes sanos, con instilación de lágrimas artificiales durante el desarrollo de diferentes requerimientos de fijación sobre dispositivos electrónicos y papel. Materiales y Métodos: estudio clínico prospectivo transversal, con participación de 35 sujetos, 30 de ellos fueron intervenidos y 6 de ellos pertenecen al grupo control; con edades comprendidas entre los 19 y 35 años. Cada uno completó el cuestionario OSDI para posteriormente evaluar su superficie ocular con el Keratograph 5M, aplicando un protocolo establecido de valoración de la película lagrimal y la conjuntiva. Las pruebas se realizaron en tres días diferentes, en cada sesión se realizó una actividad de fijación visual diferente: lectura en papel, en computador u ordenador y en teléfono móvil o celular. El grupo control realizó las actividades de fijación, en los tres días mencionados, sin instilación de lágrimas artificiales. Al grupo experimental, en cada sesión, se le instiló lágrima artificial cuya composición incluía hialuronato sódico en el ojo derecho y lágrima artificial con carboximetilcelulosa en el ojo izquierdo...
dc.description.abstractObjective: to evaluate the characteristics of the ocular surface in a group of healthy young adults, with instillation of artificial tears during the development of different fixation requirements on electronic devices and paper. Materials and Methods: prospective cross-sectional clinical study, with the participation of 35 subjects, 30 of them underwent surgery and 6 of them belonged to the control group; aged between 19 and 35 years. Each one completed the OSDI questionnaire to subsequently evaluate their ocular surface with the Keratograph 5M, applying an established protocol for evaluating the tear film and conjunctiva. The tests were carried out on three different days, in each session a different visual fixation activity was carried out: reading on paper, on a computer or computer and on a mobile or cell phone. The control group carried out the fixation activities, on the three days mentioned, without instillation of artificial tears. In each session, the experimental group was instilled with artificial tears whose composition included sodium hyaluronate in the right eye, and artificial tears with carboxymethylcellulose in the left eye...
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statusunpub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/119113
dc.language.isospa
dc.page.total209
dc.publication.placeMadrid
dc.publisherUniversidad Complutense de Madrid
dc.rights.accessRightsopen access
dc.subject.cdu617.764(043.2)
dc.subject.keywordLágrimas artificiales
dc.subject.ucmÓptica oftálmica
dc.subject.unesco2209 Óptica
dc.titleEfecto del uso de lágrimas artificiales sobre la película lagrimal y la conjuntiva para diferentes requerimientos de fijación, en adultos jóvenes y sanos
dc.typedoctoral thesis
dspace.entity.typePublication
relation.isAdvisorOfPublication3360352c-552e-4aab-aa7d-ec88baa8079e
relation.isAdvisorOfPublicationbd1d6d70-bafd-4ab0-a203-4b33b5d9cff1
relation.isAdvisorOfPublicationb7f0bd69-3ee7-4f85-9053-89850d60238f
relation.isAdvisorOfPublication.latestForDiscovery3360352c-552e-4aab-aa7d-ec88baa8079e

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
T45368.pdf
Size:
7.4 MB
Format:
Adobe Portable Document Format

Collections