Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Oxidative grafting vs. monolayers self-assembling on gold surface for the preparation of electrochemical immunosensors. Application to the determination of peptide YY

dc.contributor.authorGuerrero Irigoyen, Sara
dc.contributor.authorAgüí Chicharro, María Lourdes
dc.contributor.authorYáñez-Sedeño Orive, Paloma
dc.contributor.authorPingarrón Carrazón, José Manuel
dc.date.accessioned2024-01-11T07:50:30Z
dc.date.available2024-01-11T07:50:30Z
dc.date.issued2018
dc.description.abstractA comparison of the performance of two electrochemical immunosensors for the determination of the anorexigen biomarker peptide YY (PYY) is reported by using as scaffolds screen printed gold electrodes modified either by oxidative grafting of p-aminobenzoic acid (p-ABA) or by assembling of a 4-mercaptobenzoic acid (4-MBA) SAM. Covalent immobilization of capture antibodies on the surface-confined carboxyl groups was carried out by EDC/NHSS chemistry, and competitive immunoassays between target PYY and Biotin-PYY were implemented. Upon labeling with alkaline phosphatase (AP)-streptavidin conjugate and 1-naphtyl phosphate addition, differential pulse voltammograms recorded between −0.2 and +0.7 V were used as analytical readout. All the steps involved in the functionalization of the electrodes and the preparation of the immunosensors were monitored by electrochemical impedance spectroscopy. The calibration plot for PYY using the AP-Strept-Biotin-PYY(PYY)-anti-PYY-Phe-N-SPAuE immunosensor provided a linear current vs. log [PYY] plot extending between 10−6 and 103 ng/mL PYY with a detection limit of 3 × 10−7 ng/mL. These analytical characteristics are remarkably better than those obtained with the immunosensor prepared with 4-MBA SAM-SPAuEs. The AP-Strept-Biotin-PYY(PYY)-anti-PYY-Phe-N-SPAuE immunosensor was used to analyze human serum and saliva samples spiked with PYY at concentrations fitting with normal levels in these biological fluids.
dc.description.departmentDepto. de Química Analítica
dc.description.facultyFac. de Ciencias Químicas
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad (España)
dc.description.sponsorshipComunidad de Madrid
dc.description.statuspub
dc.identifier.citationGuerrero, S., et al. «Oxidative Grafting vs. Monolayers Self-Assembling on Gold Surface for the Preparation of Electrochemical Immunosensors. Application to the Determination of Peptide YY». Talanta, vol. 193, febrero de 2019, pp. 139-45. https://doi.org/10.1016/j.talanta.2018.09.089.
dc.identifier.doi10.1016/j.talanta.2018.09.089
dc.identifier.issn0039-9140
dc.identifier.officialurlhttps://doi.org/10.1016/j.talanta.2018.09.089
dc.identifier.urihttps://hdl.handle.net/20.500.14352/92413
dc.journal.titleTalanta
dc.language.isoeng
dc.page.final145
dc.page.initial139
dc.publisherElsevier
dc.relation.projectIDCTQ2015–70023-R
dc.relation.projectIDS2013/MT-3029
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsrestricted access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu543
dc.subject.cdu544.6:543.25
dc.subject.cdu543.25:544.6
dc.subject.keywordOxidative grafting
dc.subject.keywordElectrochemical immunosensor
dc.subject.keywordPeptide YY
dc.subject.keywordObesity
dc.subject.keywordHormones
dc.subject.keywordSerum
dc.subject.keywordSaliva
dc.subject.ucmQuímica analítica (Química)
dc.subject.unesco2301.04 Análisis Electroquímico
dc.titleOxidative grafting vs. monolayers self-assembling on gold surface for the preparation of electrochemical immunosensors. Application to the determination of peptide YY
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number193
dspace.entity.typePublication
relation.isAuthorOfPublication746c8c8c-1e81-4897-8b4f-bfb1ff9d741a
relation.isAuthorOfPublicationba1cfa29-0064-4c8d-9c24-b0093bfe6d0a
relation.isAuthorOfPublication06ab2fa0-2b2d-4b58-80ed-82f9cc767175
relation.isAuthorOfPublication8808f99c-5f56-4562-839a-517626c76dad
relation.isAuthorOfPublication.latestForDiscovery746c8c8c-1e81-4897-8b4f-bfb1ff9d741a

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Oxidative_grafting_vs._monolayers_self-assembling.pdf
Size:
802.57 KB
Format:
Adobe Portable Document Format

Collections