Evaluación de la calidad de los exámenes de tomografía computarizada de columna lumbar en la indicación de hernia discal
dc.contributor.author | Gómez León, Nieves | |
dc.contributor.author | Rodríguez González, R. | |
dc.contributor.author | Calzado Cantera, Alfonso | |
dc.contributor.author | De Pablo, A.A. | |
dc.contributor.author | Cuevas Ibáñez, A. | |
dc.contributor.author | García Castaño, B. | |
dc.contributor.author | Morán Blanco, L.M. | |
dc.contributor.author | Morán Penco, P. | |
dc.contributor.author | Turrero Nogués, Agustín | |
dc.date.accessioned | 2023-06-20T10:55:31Z | |
dc.date.available | 2023-06-20T10:55:31Z | |
dc.date.issued | 2004 | |
dc.description.abstract | Aim: To apply quality criteria of computerized tomography (CT) of the lumbar spine as defined in the European Guidelines, in four hospitals of the Community of Madrid, using spiral CT (SCT) in the clinical indication of disc hernia. Materials and Methods: There were selected 20 lumbar spine studies from each center. These were evaluated by five independent radiologists in order to determine the degree of adherence to criteria quality of the European Guidelines for such studies. Dosimetric measurements were performed in parallel in order to estimate values of CT dose index (CTDIw), dose length product (DLP) and effective dose for each patient. Results: The results showed a high degree of adherence to image quality criteria in four centers (97-100)%. Median CTDIw values per center were (34-60) mGy; those of DLP were (242-499) mGy·cm, and those of effective dose between 4 and 7 mSv. Conclusion: There has been a good adherence to the quality criteria. In some cases, however, it seems that doses could very well be reduced through a re-thinking of the protocols. | en |
dc.description.department | Depto. de Estadística e Investigación Operativa | |
dc.description.department | Depto. de Radiología, Rehabilitación y Fisioterapia | |
dc.description.faculty | Fac. de Ciencias Matemáticas | |
dc.description.faculty | Fac. de Medicina | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/30910 | |
dc.identifier.citation | Gómez León, N., Rodríguez González, R., Calzado Cantera, A. et al. «Evaluación de la calidad de los exámenes de tomografía computarizada de columna lumbar en la indicación de hernia discal». Radiología, vol. 46, n.o 4, enero de 2004, pp. 219-24. DOI.org (Crossref), https://doi.org/10.1016/S0033-8338(04)77968-0. | |
dc.identifier.doi | 10.1016/S0033-8338(04)77968-0 | |
dc.identifier.issn | 0033-8338 | |
dc.identifier.officialurl | https//doi.org/10.1016/S0033-8338(04)77968-0 | |
dc.identifier.relatedurl | http://www.sciencedirect.com/science/article/pii/S0033833804779680 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/51460 | |
dc.issue.number | 4 | |
dc.journal.title | Radiología | |
dc.page.final | 224 | |
dc.page.initial | 219 | |
dc.publisher | Elsevier | |
dc.rights.accessRights | metadata only access | |
dc.subject.cdu | 51-76 | |
dc.subject.keyword | Image Quality | |
dc.subject.keyword | Lumbar Spine | |
dc.subject.keyword | Optimization | |
dc.subject.keyword | Radiation Dose | |
dc.subject.keyword | Spiral Computerized Tomography. EMTREE medical terms: adult | |
dc.subject.keyword | Article | |
dc.subject.keyword | Clinical article | |
dc.subject.keyword | Clinical examination | |
dc.subject.keyword | Computer assisted tomography | |
dc.subject.keyword | Controlled study | |
dc.subject.keyword | Dosimetry | |
dc.subject.keyword | Europe | |
dc.subject.keyword | Hospital care | |
dc.subject.keyword | Human | |
dc.subject.keyword | Imaging system | |
dc.subject.keyword | Intervertebral disk hernia | |
dc.subject.keyword | Lumbar spine | |
dc.subject.keyword | Practice guideline | |
dc.subject.keyword | Quality control | |
dc.subject.keyword | Radiation dose | |
dc.subject.keyword | Radiologist | |
dc.subject.keyword | Spain | |
dc.subject.ucm | Estadística aplicada | |
dc.subject.ucm | Biología | |
dc.subject.unesco | 24 Ciencias de la Vida | |
dc.title | Evaluación de la calidad de los exámenes de tomografía computarizada de columna lumbar en la indicación de hernia discal | es |
dc.title.alternative | Evaluation of the Quality of CT (Computerized Tomography) Examinations of the Lumbar Spine in Indication of Disc Hernia | en |
dc.type | journal article | |
dc.volume.number | 46 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 28af5372-8320-48a8-b86f-85074dcee003 | |
relation.isAuthorOfPublication | eb5a52ca-e4ea-46ff-9e0e-c83e58834f77 | |
relation.isAuthorOfPublication.latestForDiscovery | 28af5372-8320-48a8-b86f-85074dcee003 |