Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Influence of Preoperative Astigmatism Type and Magnitude on the Effectiveness of SMILE Correction

dc.contributor.authorPérez Izquierdo, Ricardo
dc.contributor.authorRodríguez Vallejo, Manuel
dc.contributor.authorMatamoros, Alicia
dc.contributor.authorMartínez, Javier
dc.contributor.authorGarzón Jiménez, Nuria
dc.contributor.authorPoyales Galán, Francisco
dc.contributor.authorFernández, Joaquín
dc.date.accessioned2023-06-17T13:18:33Z
dc.date.available2023-06-17T13:18:33Z
dc.date.issued2019
dc.descriptionSubmitted: April 18, 2018; Accepted: November 26, 2018
dc.description.abstractPURPOSE: To assess the effectiveness of small incision lenticule extraction (SMILE) as a function of the astigmatism level and type. METHODS: A total of 102 right eyes were included in this study. Refractive astigmatism and corneal astigmatism measured with Scheimpflug technology were retrieved from the preoperative visit and the 3-month follow-up visit. Patients were split into three groups according to the preoperative refractive astigmatism (0.50, 0.75 to 1.25, and 1.50 diopters [D] or greater) and the effectiveness among each group was evaluated according to the with-the-rule (WTR), against-the-rule (ATR), and oblique classifications. The standard Alpins method was used for the analysis. RESULTS: Resultant astigmatism was not associated with its preoperative classification when the total sample was considered, but a significant association emerged between the presence of resultant astigmatism and its preoperative classification in the 1.50 D or greater group. The magnitude of error was significantly lower in the WTR (median: -0.30 D) than in the oblique and ATR astigmatism groups, resulting in a coefficient of adjustment of 1.13 for WTR astigmatism of 1.50 D or greater but not for the other types. CONCLUSIONS: Astigmatism correction with SMILE is predictable for astigmatism lower than 1.50 D without the need to apply a correction. However, higher undercorrection is present in WTR astigmatism of 1.50 D or greater.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statusinpress
dc.eprint.idhttps://eprints.ucm.es/id/eprint/50582
dc.identifier.doi10.3928/1081597X-20181127-01
dc.identifier.issn1081-597X
dc.identifier.officialurlhttp://dx.doi.org/10.3928/1081597X-20181127-01
dc.identifier.relatedurlhttps://www.healio.com/ophthalmology/journals/jrs
dc.identifier.urihttps://hdl.handle.net/20.500.14352/12967
dc.journal.titleJournal of Refractive Surgery
dc.language.isoeng
dc.publisherSlack Corporated
dc.rights.accessRightsopen access
dc.subject.cdu617.753.3-089
dc.subject.keywordAstigmatism
dc.subject.keywordSMILE correction
dc.subject.keywordPreoperative astigmatism
dc.subject.keywordastigmatism correction
dc.subject.ucmCirugía
dc.subject.ucmOftalmología
dc.subject.ucmOptometría
dc.subject.ucmAnatomía ocular
dc.subject.unesco3213 Cirugía
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco2209.15 Optometría
dc.titleInfluence of Preoperative Astigmatism Type and Magnitude on the Effectiveness of SMILE Correction
dc.typejournal article
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Garzon_Galeradas nomograma SMILE.pdf
Size:
1.48 MB
Format:
Adobe Portable Document Format

Collections