Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Multicentre study: Reliability and repeatability of Scheimpflug system measurement in keratoconus

dc.contributor.authorDe Luis Eguilor, B
dc.contributor.authorArriola Villalobos, P
dc.contributor.authorPijoan Zubizarreta, J.I
dc.contributor.authorFeijoo Lera, R
dc.contributor.authorSantamaria, A
dc.contributor.authorEtchebarria, J
dc.contributor.authorDíaz Valle, David
dc.date.accessioned2024-12-02T16:47:58Z
dc.date.available2024-12-02T16:47:58Z
dc.date.issued2021-01-01
dc.description.abstractPurpose To assess the repeatability and reliability of the most important tomographic parameters for characterising keratoconus measured with a Pentacam HR (high resolution). Methods Overall, 230 eyes in 158 patients with keratoconus were analysed. We performed five consecutive corneal tomography examinations for each eye with a Pentacam HR in patients with keratoconus. Study eyes were classified into three groups depending on the maximum posterior elevation (max_BFS_post): grade 1 for cases of keratoconus with a max_BFS_post of 40 μm; grade 2 for those with a max_BFS_post of between 41 and 75 μm and grade 3 for those with a max_BFS_post of over 75 μm. We calculated the intraclass correlation coefficients (ICCs) and repeatability limits of parameters from tomography and aberrometry. Results All the parameters were found to have excellent ICCs (0.9). The repeatability limits for the key parameters were higher than 0.5D for the power parameters, 20° for the axis of corneal astigmatism and 10 μm for the thinnest corneal thickness. Further, we obtained repeatability limits of above 0.1 μm for the aberrometry values and overall greater than 15° for the coma axis. All the values increase with the severity of keratoconus, except for that of the coma axis which falls with keratoconus grade. Conclusions The reliability indicated by ICCs supports the view that the Pentacam HR is useful for the diagnosis of keratoconus. The repeatability limits suggest that new criteria should be established for monitoring progression taking into account the real measurements that can be made using this system.
dc.description.departmentDepto. de Inmunología, Oftalmología y ORL
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationde Luis Eguileor B, Arriola-Villalobos P, Pijoan Zubizarreta JI, Feijoo Lera R, Santamaria Carro A, Diaz-Valle D, Etxebarria J. Multicentre study: reliability and repeatability of Scheimpflug system measurement in keratoconus. Br J Ophthalmol. 2021 Jan;105(1):22-26. doi: 10.1136/bjophthalmol-2019-314954. Epub 2020 Mar 26. PMID: 32217537.
dc.identifier.doi10.1136/BJOPHTHALMOL-2019-314954
dc.identifier.officialurlhttps://doi.org/10.1136/bjophthalmol-2019-314954
dc.identifier.relatedurlhttps://bjo.bmj.com/content/105/1/22.long
dc.identifier.urihttps://hdl.handle.net/20.500.14352/111899
dc.issue.number1
dc.journal.titleBritish Journal of Ophthalmology
dc.language.isoeng
dc.page.final26
dc.page.initial22
dc.publisherBMJ journal
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsrestricted access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu612.017
dc.subject.keywordKeratoconus
dc.subject.keywordProgression
dc.subject.keywordPentacam
dc.subject.keywordScheimpflug
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco32 Ciencias Médicas
dc.titleMulticentre study: Reliability and repeatability of Scheimpflug system measurement in keratoconus
dc.title.alternativeEstudio Multicéntrico: Fiabilidad y repetibilidad de las medidas con sistema de Scheimpflug en el queratocono
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number105
dspace.entity.typePublication
relation.isAuthorOfPublication3e2b98e5-5c02-400b-8823-90887624c010
relation.isAuthorOfPublication.latestForDiscovery3e2b98e5-5c02-400b-8823-90887624c010

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
bjophthalmol2020.pdf
Size:
293.75 KB
Format:
Adobe Portable Document Format

Collections