Aviso: por motivos de mantenimiento y mejora del repositorio, mañana martes día 13 de mayo, entre las 9 y las 14 horas, Docta Complutense, no funcionará con normalidad. Disculpen las molestias.
 

A Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology

dc.contributor.authorLlorens Quintana, Clara
dc.contributor.authorRico del Viejo, Laura
dc.contributor.authorSyga, Piotr
dc.contributor.authorMadrid Costa, David
dc.contributor.authorIskander, Robert
dc.date.accessioned2023-06-17T13:27:12Z
dc.date.available2023-06-17T13:27:12Z
dc.date.issued2019-07
dc.descriptionReceived: 2 August 2018 Accepted: 14 June 2019 Published: 2 August 2019
dc.description.abstractPurpose: We present and validate a new methodology for analyzing, in an automated and objective fashion, infrared images of the meibomian glands (MG). Methods: The developed algorithm consists of three main steps: selection of the region of interest, detection of MG, and analysis of MG morphometric parameters and dropout area (DOA). Additionally, a new approach to quantify the irregularity of MG is introduced. We recruited 149 adults from a general population. Infrared meibography, using Keratograph 5M, was performed. Images were assessed and graded subjectively (Meiboscore) by two experienced clinicians and objectively with the proposed automated method. Results: The correlation of subjective DOA assessment between the two clinicians was poor and the average percentage of DOA estimated objectively for each Meiboscore group did not lie within their limits. The objective assessment showed lower variability of meibography grading than that obtained subjectively. Additionally, a new grading scale of MG DOA that reduces intraclass variation is proposed. Reported values of MG length and width were inversely proportional to the DOA. Gland irregularity was objectively quantified. Conclusions: The proposed automatic and objective method provides accurate estimates of the DOA as well as additional morphologic parameters that could add valuable information in MG dysfunction understanding and diagnosis. Translational Relevance: This approach highlights the shortcomings of currently used subjective methods, and provides the clinicians with an objective, quantitative and less variable alternative for assessing MG in a noninvasive and automated fashion. It provides a viable alternative to more time-consuming subjective methods.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipUnión Europea. H2020
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/56875
dc.identifier.doi10.1167/tvst.8.4.17
dc.identifier.issn2164-2591
dc.identifier.officialurlhttps://doi.org/10.1167/tvst.8.4.17
dc.identifier.relatedurlhttps://tvst.arvojournals.org/article.aspx?articleid=2747591
dc.identifier.urihttps://hdl.handle.net/20.500.14352/13520
dc.issue.number4
dc.journal.titleTranslational vision science & technology
dc.language.isoeng
dc.publisherARVO
dc.relation.projectIDEDEN (642760)
dc.rightsAtribución-NoComercial-SinDerivadas 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/3.0/es/
dc.subject.cdu617.776-07
dc.subject.keywordMeibomian glands
dc.subject.keywordInfrared meibography
dc.subject.keywordImage processing
dc.subject.keywordObjetive medical image analysis
dc.subject.ucmAnatomía ocular
dc.subject.ucmTécnicas de la imagen
dc.titleA Novel Automated Approach for Infrared-Based Assessment of Meibomian Gland Morphology
dc.typejournal article
dc.volume.number8
dspace.entity.typePublication
relation.isAuthorOfPublication383ca857-3af5-4787-8717-d278082d1d13
relation.isAuthorOfPublication.latestForDiscovery383ca857-3af5-4787-8717-d278082d1d13

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Laura Rico_tvst_i2164-2591-8-4-17.pdf
Size:
1.29 MB
Format:
Adobe Portable Document Format

Collections