Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Electrochemical immunosensor for the determination of 8-isoprostane aging biomarker using carbon nanohorns-modified disposable electrodes

dc.contributor.authorSánchez Tirado, Esther
dc.contributor.authorGonzález Cortés, Araceli
dc.contributor.authorYudasaka, M.
dc.contributor.authorIijima, S.
dc.contributor.authorLanga, Fernando
dc.contributor.authorYáñez-Sedeño Orive, Paloma
dc.contributor.authorPingarrón Carrazón, José Manuel
dc.date.accessioned2023-06-17T22:11:24Z
dc.date.available2023-06-17T22:11:24Z
dc.date.issued2017-05
dc.description.abstractThe first electrochemical immunosensor for the determination of 8-isoprostane (8-iso prostaglandin F2α, ISO), one of the most reliable biomarkers of lipid peroxidation in the human body and of aging related to Alzheimer´s disease or atherosclerosis is reported in this article. Disposable screen-printed carbon electrodes modified with carboxylated carbon nanohorns (CNHs) were employed as scaffolds for covalent immobilization of a specific anti-ISO antibody). A competitive immunoassay involving ISO and HRPlabeled antigen was designed and the determination of ISO was carried out by amperometry at -200 mV using the H2O2/hydroquinone (HQ) system. Under the optimized conditions, the immunosensor provides a linear response for ISO (r2 = 0.998) extending up to 700 pg/mL, which is suitable for the determination of the target compound in human serum. The analytical performance of the immunosensor improves that claimed for ELISA kits in terms of linearity of the calibration plot, precision, with RSD values lower than 1 % , and assay time (1h 30min), and exhibits a low limit of detection, 12 pg/mL, a long storage stability (30 days), and an excellent selectivity against other proteins that may be found in human serum. The analytical utility of the developed immunosensor was demonstrated by determining ISO in two types of human serum samples: lyophilized spiked serum, and real human serum from healthy male and female individuals with good results.
dc.description.departmentDepto. de Química Analítica
dc.description.facultyFac. de Ciencias Químicas
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad (MINECO)
dc.description.sponsorshipComunidad de Madrid
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/45125
dc.identifier.doi10.1016/j.jelechem.2016.11.003
dc.identifier.issn1572-6657(Print), 1873-2569 (Online)
dc.identifier.officialurlhttp://www.sciencedirect.com/science/article/pii/S1572665716306075?via%3Dihub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/18192
dc.journal.titleJournal of Electroanalytical Chemistry
dc.language.isoeng
dc.page.final202
dc.page.initial197
dc.publisherElsevier
dc.relation.projectIDCTQ2015-70023-R
dc.relation.projectIDCTQ2015-71955-REDT
dc.relation.projectIDNANOAVANSENS (S2013/MT-3029)
dc.rights.accessRightsopen access
dc.subject.cdu543
dc.subject.keywordAging biomarkersElectrochemical immunosensors8-isoprostaneProstaglandin
dc.subject.ucmQuímica analítica (Química)
dc.subject.unesco2301 Química Analítica
dc.titleElectrochemical immunosensor for the determination of 8-isoprostane aging biomarker using carbon nanohorns-modified disposable electrodes
dc.typejournal article
dc.volume.number793
dspace.entity.typePublication
relation.isAuthorOfPublication8ce0e95b-049c-4147-be76-110e258443a1
relation.isAuthorOfPublication8a730734-cdf5-4b59-b017-12e2320c872e
relation.isAuthorOfPublication06ab2fa0-2b2d-4b58-80ed-82f9cc767175
relation.isAuthorOfPublication8808f99c-5f56-4562-839a-517626c76dad
relation.isAuthorOfPublication.latestForDiscovery8ce0e95b-049c-4147-be76-110e258443a1

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2016 JEC isoprostano (Araceli).pdf
Size:
846.21 KB
Format:
Adobe Portable Document Format

Collections