Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Comparison of rebound tonometer and goldmann handheld applanation tonometer in congenital glaucoma

dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.contributor.authorGarcía Feijoo, Julián
dc.contributor.authorSaenz Frances, F.
dc.contributor.authorVizzeri, G
dc.contributor.authorFernández Vidal, Ana María
dc.contributor.authorMéndez Hernández, Carmen Dora
dc.contributor.authorGarcía Sánchez, Julián
dc.date.accessioned2024-08-02T09:43:10Z
dc.date.available2024-08-02T09:43:10Z
dc.date.issued2009
dc.description.abstractPURPOSE: To compare intraocular pressure (IOP) measurements obtained using the rebound tonometer (RBT) and the handheld Goldmann applanation tonometer (Perkins) in children with congenital glaucoma. METHODS: Using both tonometers, the IOP was prospectively determined in 68 eyes of 68 patients with congenital glaucoma aged 3 to 13 years. Corneal curvature, central corneal thickness (CCT), and axial length were also measured in each patient. The ease of the use of each tonometer was scored using a visual analog scale. RESULTS: IOP readings obtained using the RBT and Perkins tonometer showed good correlation (r=0.869, P<0.001) although RBT readings were consistently higher (mean difference: 3.1 ±4.0'mm Hg). According to the Bland-Altman plot, the 95% limits of agreement between the 2 methods were -4.8 to 10.9'mm Hg (slope=0.589, P<0.001). When estimating CCT, the 2 tonometers behaved similarly and correlation was observed between IOP measurements and CCT, with higher IOPs obtained as the CCT increased. In contrast, no correlation was detected between corneal curvature or axial length and the IOPs recorded using either tonometer. Ease of use scores awarded by the examiner was higher for the RBT. CONCLUSIONS: The RBT overestimates the IOP compared with the Perkins tonometer in patients with congenital glaucoma. Differences in readings between the 2 tonometers become larger as the CCT increases. © 2009 by Lippincott Williams & Wilkins.
dc.description.departmentDepto. de Inmunología, Oftalmología y ORL
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationMartinez-de-la-Casa JM, Garcia-Feijoo J, Saenz-Frances F, Vizzeri G, Fernandez-Vidal A, Mendez-Hernandez C, Garcia-Sanchez J. Comparison of rebound tonometer and Goldmann handheld applanation tonometer in congenital glaucoma. J Glaucoma. 2009 Jan;18(1):49-52. doi: 10.1097/IJG.0b013e31816f760c. PMID: 19142135.
dc.identifier.doi10.1097/IJG.0B013E31816F760C
dc.identifier.officialurlhttps://doi.org/10.1097/IJG.0B013E31816F760C
dc.identifier.relatedurlhttps://journals.lww.com/glaucomajournal/fulltext/2009/01000/comparison_of_rebound_tonometer_and_goldmann.9.aspx
dc.identifier.urihttps://hdl.handle.net/20.500.14352/107358
dc.issue.number1
dc.journal.titleJournal of Glaucoma
dc.language.isoeng
dc.page.final52
dc.page.initial49
dc.publisherLippincott, Williams & Wilkins
dc.rights.accessRightsrestricted access
dc.subject.cdu617.7
dc.subject.keywordGlaucoma
dc.subject.keywordRebound
dc.subject.keywordGoldmann
dc.subject.keywordCongenital glaucoma
dc.subject.keywordPerkins
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco32 Ciencias Médicas
dc.titleComparison of rebound tonometer and goldmann handheld applanation tonometer in congenital glaucoma
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number18
dspace.entity.typePublication
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublicationa2727b5b-8b4b-4841-a173-75c1d2663a45
relation.isAuthorOfPublication533dd90f-2b34-4a5f-9cf8-ab8d19454edd
relation.isAuthorOfPublicationeff24faf-e089-4604-906d-bbd7f42be7f1
relation.isAuthorOfPublication.latestForDiscovery273a99c3-2c9f-4dd0-8939-b7ff3593124c

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Rebound vs. Goldmann Tonometer in Congenital Glaucoma - Martinez-de-la-Casa et al. (2009) - J Glaucoma.pdf
Size:
112.85 KB
Format:
Adobe Portable Document Format

Collections