Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Analysis of health impact assessment to outdoor and indoor air pollution in a prototype building in Madrid (Spain)

dc.contributor.authorSan José, Roberto
dc.contributor.authorPérez, Juan L.
dc.contributor.authorPérez, Libia
dc.contributor.authorGonzález Barras, Rosa María
dc.date.accessioned2023-06-17T09:03:01Z
dc.date.available2023-06-17T09:03:01Z
dc.date.issued2020
dc.description© 2020 The Author(s). International Conference on Atmospheric Sciences and Applications to Air Quality (ASSAQ) (15th. 2019. Kuala Lumpur/Malaysia). The UPM authors thankfully acknowledge the computer resources, technical expertise and assistance provided by the Centro de Supercomputación y Visualización de Madrid (CESVIMA).
dc.description.abstractPeople spend major part of their time inside places such as homes and offices, so it is very important to know the indoor and outdoor pollution in this type of studies. The atmospheric dispersion model WRF/Chem is used to know the outdoor pollution and meteorological conditions with high spatial (1 km) and temporal (1-hour) resolution and the building energy model EnergyPlus to simulate the indoor contaminants. EnergyPlus model is used to investigate the dynamic behaviour of pollutants with a single package using a multizone approach. 2016 year is used for the simulations with hourly outputs. Outdoor and indoor pollutions are linked to through the simulated infiltration process. The evaluation of outdoor, indoor air quality and human health effects was carried out considering different exposure profiles, for people working and living in an office and house located in the same building in the Madrid city center. The study takes into account different ventilation modes in the building and indoor emission scenarios (oven for heating, cooking, photocopy machine, smoke cigarettes). Health impact assessment considered mortality and hospital admissions, associated with exposure to PM2.5 and NO2 taking into account the differences between the exposure profiles, which have been used to describe the time activity patterns of the people. The health impacts of emitting sources are highest in the warm months due to the operation of the air conditioning system. The health impact of indoor emission sources is higher than the outdoor pollution. People in the zone where the emitting sources are located would experience a mortality and morbidity of 2.5 times more than in the non-emitting zones.
dc.description.departmentDepto. de Física de la Tierra y Astrofísica
dc.description.facultyFac. de Ciencias Físicas
dc.description.refereedTRUE
dc.description.sponsorshipCentro de Supercomputación y Visualización de Madrid (CESVIMA)
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/65018
dc.identifier.doi10.1088/1755-1315/489/1/012010
dc.identifier.isbn1755-1307
dc.identifier.issn1755-1307
dc.identifier.officialurlhttps://doi.org/10.1088/1755-1315/489/1/012010
dc.identifier.relatedurlhttps://iopscience.iop.org/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/8036
dc.journal.titleIOP Conference Series: Earth and Environmental Science
dc.language.isoeng
dc.publisherIOP Publishing
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu52
dc.subject.keywordExposure
dc.subject.keywordEnergy
dc.subject.keywordPM2.5
dc.subject.ucmFísica atmosférica
dc.subject.unesco2501 Ciencias de la Atmósfera
dc.titleAnalysis of health impact assessment to outdoor and indoor air pollution in a prototype building in Madrid (Spain)
dc.typejournal article
dc.volume.number489
dspace.entity.typePublication
relation.isAuthorOfPublication746692d1-0439-4f3f-87de-caaa8a90ba81
relation.isAuthorOfPublication.latestForDiscovery746692d1-0439-4f3f-87de-caaa8a90ba81

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
GBarrasRM 03libre+CC.pdf
Size:
1.15 MB
Format:
Adobe Portable Document Format

Collections