Rad-Tol Pt-100 isolation amplifiers for the LHC cryogenic system
dc.book.title | Proceedings of the tenth Workshop on Electronics for LHC Experiments | |
dc.contributor.author | Agapito Serrano, Juan Andrés | |
dc.contributor.author | Casas-Cubillos, Juan | |
dc.contributor.author | Fernandes, Ana C. | |
dc.contributor.author | Franco Peláez, Francisco Javier | |
dc.contributor.author | Gonçalves, Isabel | |
dc.contributor.author | Hernández Cachero, Antonio | |
dc.contributor.author | Marques, José G. | |
dc.contributor.author | Rodríguez-Ruiz, Miguel Ángel | |
dc.contributor.author | Zong, Yi | |
dc.date.accessioned | 2023-06-20T13:41:27Z | |
dc.date.available | 2023-06-20T13:41:27Z | |
dc.date.issued | 2004-08-13 | |
dc.description | © 2004 CERN (License: CC-BY-3.0). Workshop on Electronics for LHC Experiments (10. 2004. Boston, MA, USA) | |
dc.description.abstract | The cryogenic system of the LHC will use Pt-100 sensors to measure temperatures between 40-300K and isolation devices will be used. The selected commercial components must be rad-tolerant since a total radiation dose of 5E12 n/cm2 &100 Gy is expected during ten years of the LHC lifetime. Neutron tests in this family of devices were performed and the results are shown in this paper. | |
dc.description.department | Depto. de Estructura de la Materia, Física Térmica y Electrónica | |
dc.description.faculty | Fac. de Ciencias Físicas | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Ministerio de Educación y Ciencia | |
dc.description.sponsorship | CERN | |
dc.description.sponsorship | Portuguese Research Agency (ICCTI) | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/29016 | |
dc.identifier.doi | 10.5170/CERN-2004-010.402 | |
dc.identifier.isbn | 92-9083-237-1 | |
dc.identifier.issn | 0007-8328 | |
dc.identifier.officialurl | http://dx.doi.org/10.5170/CERN-2004-010.402 | |
dc.identifier.relatedurl | http://cds.cern.ch/record/814710 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/53398 | |
dc.journal.title | Proceedings of the 10th Workshop on Electronics for LHC and Future Experiments | |
dc.language.iso | eng | |
dc.page.final | 121 | |
dc.page.initial | 117 | |
dc.page.total | 5 | |
dc.publication.place | Geneva, Switzerland | |
dc.publisher | CERN Publishing Service | |
dc.relation.projectID | FPA2002-00912 | |
dc.relation.projectID | K476/LHC | |
dc.rights | Atribución 3.0 España | |
dc.rights.accessRights | open access | |
dc.rights.uri | https://creativecommons.org/licenses/by/3.0/es/ | |
dc.subject.cdu | 537.8 | |
dc.subject.keyword | Radiation | |
dc.subject.keyword | Instrumentation | |
dc.subject.keyword | CERN | |
dc.subject.ucm | Electrónica (Física) | |
dc.subject.ucm | Radiactividad | |
dc.title | Rad-Tol Pt-100 isolation amplifiers for the LHC cryogenic system | |
dc.type | book part | |
dcterms.references | [1] A. J Peyton, V. Walsh, “Analog Electronic with Op Amps: a source book of practical circuits”, Cambridge University Press, Cambridge, UK, 1993 [2] G.Messenger, M. Ash “The Effects of Radiation on Electronic Systems”, New York, Van Nostrand Reinhold, Second Edition, 1992 [3] V. Remondino,“Radiation damage in amplifiers used for quench detection in a superconducting accelerator”, 3rd European Conference on Radiation and its Effects on Components and Systems, 18-22 Sept. 1995, pp. 89-93 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 662ba05f-c2fc-4ad7-9203-36924c80791a | |
relation.isAuthorOfPublication | 61e3c731-f799-4eee-b4c2-7e5ad8b417c2 | |
relation.isAuthorOfPublication.latestForDiscovery | 662ba05f-c2fc-4ad7-9203-36924c80791a |
Download
Original bundle