Three-year follow-up of posterior chamber phakic intraocular lens with a central port design after deep anterior lamellar keratoplasty
dc.contributor.author | Alfonso Bartolozzi, Belén | |
dc.contributor.author | Lisa Fernández, Carlos | |
dc.contributor.author | Fernández Vega-Cueto, Luis | |
dc.contributor.author | Baamonde Arbaiza, Begoña | |
dc.contributor.author | Madrid Costa, David | |
dc.contributor.author | Alfonso Sánchez, José F. | |
dc.date.accessioned | 2023-06-22T12:53:38Z | |
dc.date.available | 2023-06-22T12:53:38Z | |
dc.date.issued | 2022-09-07 | |
dc.description.abstract | Background: To evaluate clinical outcomes of the Visian implantable collamer lens (ICL) with a central port to correct myopia and astigmatism after deep anterior lamellar keratoplasty (DALK) for keratoconus throughout 3 years of follow-up. Methods: This study included 20 eyes of 20 patients that underwent V4c ICL (13 eyes with a spherical ICL and 7 eyes with a toric ICL) implantation after DALK. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure (IOP), endothelial cell density (ECD), and vault were analyzed. Results: The mean UDVA improved from the preoperative 1.18 ± 0.33 logMAR to 0.25 ± 0.14 logMAR at 6 months after surgery (P < 0.0001) and remained unchanged throughout the whole follow-up (P = 0.4). All eyes gained lines of CDVA compared to preoperative values. At the last follow-up visit, all eyes achieved CDVA of 0.2 logMAR or better and 13 eyes (65%) 0.1 logMAR or better. At 6 months post-surgery, all eyes (100%) had a spherical equivalent within ± 1.50 D, and 19 (95%) within ± 1.00 D. The mean manifest spherical equivalent was stable over the postoperative follow-up (P = 0.25). No significant increase in IOP occurred in any case throughout the 3 years of follow-up. The loss in ECD from the preoperative baseline at the last follow-up visit was 2.27%. Conclusions: The clinical outcomes suggest that the V4c ICL implantation for correction of myopia and regular astigmatism in post-DALK eyes was satisfactory in terms of effectiveness, safety, and stability during 3 years of follow-up. | |
dc.description.department | Depto. de Optometría y Visión | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | STAAR® Surgical (Estados Unidos) | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/77685 | |
dc.identifier.doi | 10.1186/s40662-022-00306-1 | |
dc.identifier.issn | 2326-0254 | |
dc.identifier.officialurl | https://doi.org/10.1186/s40662-022-00306-1 | |
dc.identifier.relatedurl | https://eandv.biomedcentral.com/articles/10.1186/s40662-022-00306-1 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/73300 | |
dc.issue.number | 1 | |
dc.journal.title | Eye and Vision | |
dc.language.iso | eng | |
dc.page.final | 9 p. | |
dc.page.initial | art.34 | |
dc.publisher | BMC | |
dc.rights | Atribución 3.0 España | |
dc.rights.accessRights | open access | |
dc.rights.uri | https://creativecommons.org/licenses/by/3.0/es/ | |
dc.subject.cdu | 617.713-089 | |
dc.subject.cdu | 617.7-089.243 | |
dc.subject.cdu | 681.73 | |
dc.subject.keyword | DALK | |
dc.subject.keyword | Deep anterior lamellar keratoplasty | |
dc.subject.keyword | ICL | |
dc.subject.keyword | Implantable collamer lens. | |
dc.subject.ucm | Cirugía | |
dc.subject.ucm | Oftalmología | |
dc.subject.ucm | Optometría | |
dc.subject.unesco | 3213 Cirugía | |
dc.subject.unesco | 3201.09 Oftalmología | |
dc.subject.unesco | 2209.15 Optometría | |
dc.title | Three-year follow-up of posterior chamber phakic intraocular lens with a central port design after deep anterior lamellar keratoplasty | |
dc.type | journal article | |
dc.volume.number | 9 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 383ca857-3af5-4787-8717-d278082d1d13 | |
relation.isAuthorOfPublication.latestForDiscovery | 383ca857-3af5-4787-8717-d278082d1d13 |
Download
Original bundle
1 - 1 of 1