Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Three-year follow-up of posterior chamber phakic intraocular lens with a central port design after deep anterior lamellar keratoplasty

dc.contributor.authorAlfonso Bartolozzi, Belén
dc.contributor.authorLisa Fernández, Carlos
dc.contributor.authorFernández Vega-Cueto, Luis
dc.contributor.authorBaamonde Arbaiza, Begoña
dc.contributor.authorMadrid Costa, David
dc.contributor.authorAlfonso Sánchez, José F.
dc.date.accessioned2023-06-22T12:53:38Z
dc.date.available2023-06-22T12:53:38Z
dc.date.issued2022-09-07
dc.description.abstractBackground: To evaluate clinical outcomes of the Visian implantable collamer lens (ICL) with a central port to correct myopia and astigmatism after deep anterior lamellar keratoplasty (DALK) for keratoconus throughout 3 years of follow-up. Methods: This study included 20 eyes of 20 patients that underwent V4c ICL (13 eyes with a spherical ICL and 7 eyes with a toric ICL) implantation after DALK. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure (IOP), endothelial cell density (ECD), and vault were analyzed. Results: The mean UDVA improved from the preoperative 1.18 ± 0.33 logMAR to 0.25 ± 0.14 logMAR at 6 months after surgery (P < 0.0001) and remained unchanged throughout the whole follow-up (P = 0.4). All eyes gained lines of CDVA compared to preoperative values. At the last follow-up visit, all eyes achieved CDVA of 0.2 logMAR or better and 13 eyes (65%) 0.1 logMAR or better. At 6 months post-surgery, all eyes (100%) had a spherical equivalent within ± 1.50 D, and 19 (95%) within ± 1.00 D. The mean manifest spherical equivalent was stable over the postoperative follow-up (P = 0.25). No significant increase in IOP occurred in any case throughout the 3 years of follow-up. The loss in ECD from the preoperative baseline at the last follow-up visit was 2.27%. Conclusions: The clinical outcomes suggest that the V4c ICL implantation for correction of myopia and regular astigmatism in post-DALK eyes was satisfactory in terms of effectiveness, safety, and stability during 3 years of follow-up.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipSTAAR® Surgical (Estados Unidos)
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/77685
dc.identifier.doi10.1186/s40662-022-00306-1
dc.identifier.issn2326-0254
dc.identifier.officialurlhttps://doi.org/10.1186/s40662-022-00306-1
dc.identifier.relatedurlhttps://eandv.biomedcentral.com/articles/10.1186/s40662-022-00306-1
dc.identifier.urihttps://hdl.handle.net/20.500.14352/73300
dc.issue.number1
dc.journal.titleEye and Vision
dc.language.isoeng
dc.page.final9 p.
dc.page.initialart.34
dc.publisherBMC
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu617.713-089
dc.subject.cdu617.7-089.243
dc.subject.cdu681.73
dc.subject.keywordDALK
dc.subject.keywordDeep anterior lamellar keratoplasty
dc.subject.keywordICL
dc.subject.keywordImplantable collamer lens.
dc.subject.ucmCirugía
dc.subject.ucmOftalmología
dc.subject.ucmOptometría
dc.subject.unesco3213 Cirugía
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco2209.15 Optometría
dc.titleThree-year follow-up of posterior chamber phakic intraocular lens with a central port design after deep anterior lamellar keratoplasty
dc.typejournal article
dc.volume.number9
dspace.entity.typePublication
relation.isAuthorOfPublication383ca857-3af5-4787-8717-d278082d1d13
relation.isAuthorOfPublication.latestForDiscovery383ca857-3af5-4787-8717-d278082d1d13

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
s40662-022-00306-1.pdf
Size:
880.44 KB
Format:
Adobe Portable Document Format

Collections