Changes in retinal nerve fiber layer thickness measurements in response to a trifocal intraocular lens implantation

dc.contributor.authorGarcía-Bella, Javier
dc.contributor.authorTalavero-González, Paula
dc.contributor.authorCarballo Álvarez, Jesús
dc.contributor.authorSanz Fernández, Jesús
dc.contributor.authorVázquez-Moliní, Jesús
dc.contributor.authorGarcía Feijoo, Julián
dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.date.accessioned2025-01-09T15:59:25Z
dc.date.available2025-01-09T15:59:25Z
dc.date.issued2018-06-11
dc.description.abstractAims: To determine the changes produced on the peripapillary retinal nerve fiber layer (RNFL) thickness, measured by an spectral-domain optical coherence tomography (OCT), after the implantation of a trifocal diffractive intraocular lens (IOL) and compare them with the variations produced by a monofocal IOL implantation. Methods: A prospective, double masked study in which 50 eyes belonging to 50 patients with bilateral cataract were enrolled. Sequentially, the first 25 patients were bilaterally implanted with the trifocal diffractive IOL AT LISA® Tri 839 MP and the following 25 patients with the monofocal IOL CT ASPHINA® 409 M/MP. RNFL thickness measurements were performed by Cirrus HD®-OCT before and six months after the second eye surgery. Results: Mean patient age was 69.5 ± 6.1 years. In response to surgery, the average RNFL thickness increased 7.29 ± 10.51 µm at the AT LISA® Tri group and 1.96 ± 2.90 µm at the monofocal IOL group from the baseline (p = 0.017). Statistically significant differences in thickness variations were also detected in the superior sector (7.86 ± 7.70 µm at the AT LISA® Tri group vs 1.73 ± 5.74 µm at the monofocal group). Statistically significant differences between the pre and the postsurgery measurements were found in all sectors except the inferior one with the trifocal IOL and in two of the studied sectors (average and temporal) with the monofocal IOL. Conclusions: The IOL implantation produce changes in the RNFL thickness, which are larger in case of a trifocal diffractive IOL.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.facultyInstituto de Investigaciones Oftalmológicas Ramón Castroviejo
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationGarcía-Bella J, Talavero-González P, Carballo-Álvarez J, Sanz-Fernández JC, Vázquez-Moliní JM, García-Feijóo J, Martínez-de-la-Casa JM. Changes in retinal nerve fiber layer thickness measurements in response to a trifocal intraocular lens implantation. Eye (Lond). 2018 Oct;32(10):1574-1578. doi: 10.1038/s41433-018-0141-0. Epub 2018 Jun 11. PMID: 29891898; PMCID: PMC6189210.
dc.identifier.doi10.1038/s41433-018-0141-0
dc.identifier.officialurlhttps://doi.org/10.1038/s41433-018-0141-0
dc.identifier.urihttps://hdl.handle.net/20.500.14352/113567
dc.journal.titleEYE
dc.language.isoeng
dc.page.final1578
dc.page.initial1574
dc.publisherSpringer
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu611.843
dc.subject.cdu617.7-089.243
dc.subject.keywordIntraocular lens
dc.subject.keywordTrifocal
dc.subject.keywordRetinal nerve
dc.subject.keywordCataract
dc.subject.ucmOftalmología
dc.subject.ucmÓptica fisiológica
dc.subject.ucmÓptica (Física)
dc.subject.ucmÓptica y optometría
dc.subject.unesco2209 Óptica
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco2209.15 Optometría
dc.titleChanges in retinal nerve fiber layer thickness measurements in response to a trifocal intraocular lens implantation
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number32
dspace.entity.typePublication
relation.isAuthorOfPublicationd90c8dc9-5aef-4047-950e-c6c59469ec3f
relation.isAuthorOfPublicationdd64c1e9-d911-48d0-a3f4-f55c2d73f832
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication.latestForDiscoveryd90c8dc9-5aef-4047-950e-c6c59469ec3f

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Changes_in_retinal_nerve_fiber_layer_thickness_measurements_in_response_to_a_trifocal_intraocular_lens.pdf
Size:
370.92 KB
Format:
Adobe Portable Document Format

Collections