Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Toric Intraocular Lens Results Considering Posterior Corneal Astigmatism with Online Calculators: Phacoemulsification vs. Femtosecond

dc.contributor.authorFernández, Joaquín
dc.contributor.authorRodríguez Vallejo, Manuel
dc.contributor.authorBurguera, Noemí
dc.contributor.authorSalvestrini, Patrizia
dc.contributor.authorGarzón Jiménez, Nuria
dc.date.accessioned2023-06-16T14:15:51Z
dc.date.available2023-06-16T14:15:51Z
dc.date.issued2021-09-03
dc.descriptionReceived: 19 July 2021 / Revised: 26 August 2021 / Accepted: 1 September 2021 / Published: 3 September 2021 (This article belongs to the Special Issue Novel Research on Optometry and Vision Sciences)
dc.description.abstractTo evaluate the prediction error (PE) obtained in Phacoemulsification (Phaco) or Femtosecond (Femto) surgeries without considering posterior corneal astigmatism correction (non-PCA) versus the correction based on Abulafia-Koch + Medicontur (AK) and Barrett calculators in toric intraocular lens (IOL) power calculation. 58 right eyes were retrospectively retrieved from our dattabase. Two groups formed by 28 and 30 eyes depending on the surgery type, Phaco or Femto respectively, were defined. Astigmatism PE were evaluated considering the approach used for calculation of the implanted IOL power (AK) versus the estimation of PEs in non-PCA and Barrett formula. A doubly-multivariate analysis was conducted to assess the differences between-surgery types, within-methods of calculation, and interaction. Mean centroid PE was significantly different between non-PCA, AK and Barrett approaches (p < 0.0005), and neither differences (p < 0.239) nor interaction (p = 0.672) between Phaco or Femto were found. Post-hoc univariate analysis showed a higher PE for the x-component of the non-PCA method versus AK (0.15 D, p < 0.0005) and non-PCA versus Barrett (0.18 D, p < 0.0005), though no differences were found between AK and Barrett (0.03 D, p = 0.93). Against-the-rule under-correction and with-the-rule overcorrection were found in both arms when PCA was not considered. Both calculators provide comparable clinical results.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/67681
dc.identifier.doi10.3390/opt2030017
dc.identifier.issn2673-3269
dc.identifier.officialurlhttps://doi.org/10.3390/opt2030017
dc.identifier.relatedurlhttps://www.mdpi.com/2673-3269/2/3/17
dc.identifier.urihttps://hdl.handle.net/20.500.14352/4417
dc.issue.number3
dc.journal.titleOptics
dc.language.isoeng
dc.page.initial9 p.
dc.publisherMDPI
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu617.7‑089.243
dc.subject.cdu617.753.3
dc.subject.cdu681.73
dc.subject.keywordToric intraocular lens
dc.subject.keywordPrediction error
dc.subject.keywordPosterior corneal astigmatism
dc.subject.keywordFemtosecond
dc.subject.keywordPhacoemulsification
dc.subject.ucmLentes de contacto
dc.subject.ucmOptometría
dc.subject.unesco3311.11 Instrumentos ópticos
dc.subject.unesco2209.15 Optometría
dc.titleToric Intraocular Lens Results Considering Posterior Corneal Astigmatism with Online Calculators: Phacoemulsification vs. Femtosecond
dc.typejournal article
dc.volume.number2
dspace.entity.typePublication
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscovery367ce491-287f-4b2a-ba6a-870a393c5609

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
optics-02-00017.pdf
Size:
1.13 MB
Format:
Adobe Portable Document Format

Collections