Reliability of retinopathy of prematurity diagnosis by analyzing digital images using telemedicine system.
dc.conference.date | 4-5 de noviembre, 2011 | |
dc.conference.place | Valencia, España. | |
dc.conference.title | Sociedad De Investigación de Retina de la Comunidad Valenciana (SIRCOVA) y ARVO | |
dc.contributor.author | Navarro Blanco, Carolina | |
dc.contributor.author | Chamorro Gutiérrez, E. | |
dc.contributor.author | Bonnin Arias, Cristina Natalia | |
dc.contributor.author | Pastora Salvador, Natalia | |
dc.contributor.author | Graboska, A. | |
dc.contributor.author | Amorena, G. | |
dc.contributor.author | Sánchez Ramos, Celia | |
dc.date.accessioned | 2024-10-04T14:34:52Z | |
dc.date.available | 2024-10-04T14:34:52Z | |
dc.date.issued | 2011-11-05 | |
dc.description.abstract | PURPOSE: To evaluate interobserver´s concordance in retinopathy of prematurity diagnosis and treatment by analyzing digital images. MATERIALS AND METHODS: descriptive, comparative observational study. The study sample was made up of 14 reconstructed retinal pictures obteined in 5 eyes of 3 low-birth-weight infants taken using a wide-angle fundus digital camera Retcam 120 (Clarity Medical Systems, Pleasanton, CA). All the images were examined by 1 experinced ophthalmologist and 6 ophthalmologist trained previously in digital image analysis. Retinographies were graded according to the systems Interantional Classification of Retinopathy of Prematurity revisited (ICROP) and Early Treatment for Retinopathy of Prematurity (ETROP). Interobserver´s concordance was assessed for each of the 6 specialist ophthalmologists regarding the ROP. | |
dc.description.department | Depto. de Optometría y Visión | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/108657 | |
dc.language.iso | eng | |
dc.rights.accessRights | open access | |
dc.subject.cdu | 535.31 | |
dc.subject.cdu | 617.751.9 | |
dc.subject.keyword | Retinopathy of prematirity | |
dc.subject.keyword | Digital images | |
dc.subject.keyword | Telemedicine system | |
dc.subject.ucm | Óptica y optometría | |
dc.subject.ucm | Baja visión | |
dc.subject.ucm | Óptica geométrica e instrumental | |
dc.subject.unesco | 2209 Óptica | |
dc.subject.unesco | 2209.15 Optometría | |
dc.title | Reliability of retinopathy of prematurity diagnosis by analyzing digital images using telemedicine system. | |
dc.title.alternative | Fiabilidad del diagnóstico de la retinopatía del prematuro mediante el análisis de imágenes digitales utilizando un sistema de telemedicina. | |
dc.type | conference paper | |
dc.type.hasVersion | AM | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 19ac822d-54b6-4b68-b13b-2179931a3900 | |
relation.isAuthorOfPublication | bd1d6d70-bafd-4ab0-a203-4b33b5d9cff1 | |
relation.isAuthorOfPublication | 2edfaee0-e9fb-434f-aa66-87fcbb3ca5a3 | |
relation.isAuthorOfPublication | 3360352c-552e-4aab-aa7d-ec88baa8079e | |
relation.isAuthorOfPublication.latestForDiscovery | 19ac822d-54b6-4b68-b13b-2179931a3900 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Reliability_of_retinopathy_of_prematurity_diagnosis_by_analyzing.pdf
- Size:
- 255.83 KB
- Format:
- Adobe Portable Document Format