Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Optical and Clinical Outcomes of an Isofocal Intraocular Lens vs. a Monofocal Standard Lens

dc.contributor.authorPérez Sanz, Lidia
dc.contributor.authorGonzález Fernández, Verónica
dc.contributor.authorGómez Pedrero, José Antonio
dc.contributor.authorAlbarrán Diego , César
dc.contributor.authorGarcía Montero, María
dc.contributor.authorGarzón Jiménez, Nuria
dc.date.accessioned2023-11-15T18:36:09Z
dc.date.available2023-11-15T18:36:09Z
dc.date.issued2023-09-30
dc.description.abstractThe aim of this study is to evaluate the results obtained on the optical bench and clinically with an isofocal lens (ISOPure, BVI medical, Belgium) to compare them to a standard monofocal one (MicroPure, BVI medical, Belgium). To do so, we have combined laboratory investigation and a prospective, comparative, and randomized clinical study. First, we have measured the wavefront of the two models studied using a NIMO TR1504 (Lambda-X, Belgium) deflectometer for three nominal powers: +10.00, +20.00 and +30.00 D. In the randomized study with 48 patients, half of them implanted with ISOPure and the other with MicroPure, we have measured visual acuities and contrast sensitivity under photopic and mesopic conditions. The optical bench results show that the isofocal lens presented higher power than the monofocal one, at the lens center, due to the spherical aberration (coefficients Z(4,0), Z(6,0) and Z(8,0)) induced by the greater asphericity of its design. The addition obtained depended on the nominal power, from +1.00 to +1.50 D. The results of the clinical study showed that the ISOPure lens presented better visual outcomes, which were statistically significant, at intermediate distance compared to the MicroPure lens (p-values of 0.014 and 0.022 for 80 and 60 cm, respectively) without decreasing the contrast sensitivity. Clinical outcomes were not affected by pupillary size. In conclusion, due to the increase in power at the lens center due to its highly aspherical design, the isofocal lens evaluated showed better intermediate vision than the monofocal one.
dc.description.departmentDepto. de Optometría y Visión
dc.description.departmentDepto. de Óptica
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.sponsorshipAgencia Estatal de Investigación (España)
dc.description.statuspub
dc.identifier.citationPérez-Sanz L, Gonzalez-Fernandez V, Gómez-Pedrero JA, Albarrán-Diego C, García-Montero M, Garzón N. Optical and Clinical Outcomes of an Isofocal Intraocular Lens vs. a Monofocal Standard Lens. Life. 2023; 13(10):2001. https://doi.org/10.3390/life13102001
dc.identifier.doi10.3390/life13102001
dc.identifier.essn2075-1729
dc.identifier.officialurlhttps://doi.org/10.3390/life13102001
dc.identifier.relatedurlhttps://www.mdpi.com/2075-1729/13/10/2001
dc.identifier.urihttps://hdl.handle.net/20.500.14352/88736
dc.issue.number10
dc.journal.titleLife
dc.language.isoeng
dc.page.initialart.2001
dc.publisherMDPI
dc.relation.projectIDPID2021-122486OA-I00
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu617.7-089.243
dc.subject.cdu681.73
dc.subject.cdu617.741-004.1
dc.subject.keywordcataract; isofocal; extended depth of focus; intraocular lens
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica oftálmica
dc.subject.ucmOftalmología
dc.subject.unesco2209.15 Optometría
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco3311.09 Lentes
dc.titleOptical and Clinical Outcomes of an Isofocal Intraocular Lens vs. a Monofocal Standard Lens
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number13
dspace.entity.typePublication
relation.isAuthorOfPublicationaa913134-98ab-438d-b8ac-14620d5e3261
relation.isAuthorOfPublication5c5cb6be-771c-40ed-8af0-cdfdbdfb3d36
relation.isAuthorOfPublication9b637d56-481e-40c6-a0e6-eb4de92e663c
relation.isAuthorOfPublication367ce491-287f-4b2a-ba6a-870a393c5609
relation.isAuthorOfPublication.latestForDiscoveryaa913134-98ab-438d-b8ac-14620d5e3261

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
life-13-02001 (1).pdf
Size:
928.07 KB
Format:
Adobe Portable Document Format

Collections