Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Effect of Yellow filter on mesopic contrast threshold with and without glare in myopia corrected by laser in situ keratomileusis (lasik).

dc.conference.date4-9 mayo, 2003
dc.conference.placeFort Lauderdale, Florida, Estados Unidos.
dc.conference.titleAssociation for research in vision and ophthalmology (ARVO)
dc.contributor.authorPérez Carrasco, María Jesús
dc.contributor.authorPuell Marín, María Cinta
dc.contributor.authorSánchez Ramos, Celia
dc.date.accessioned2024-09-09T16:49:40Z
dc.date.available2024-09-09T16:49:40Z
dc.date.issued2003-05-09
dc.description.abstractPURPOSE: To determine the effect of a coated yellow filter on contrast threshold with an without glare under mesopic conditions in eyes having uncomplicated excimer laser in situ keratomileusis (LASIK) for myopia. METHODS: The mesopic contrast threshold was measured in the absence or presence of glare using the Mesoptometer II test in 35 right eyes of adult subjects (mean age 36.9 +- 7.4) after 12 and 60 months of LASIK surgery, with and without coated yellow filter ( 482nm cut-off) and 30 emmetropic eyes of adult subjects (mean age 35.2+-4.7) as control group. RESULTS: Lasik group didn`t discrimate the lowest contrast threshold without glare, however a 73.33% of control group reached it. When the yellow filter was interposed in the lasik group the proportion of subjects who discriinated the lowest contrast threshold increased by 20%. With glare, 11.43% of lasik group´s subjects reached the lowest contrast threshold increasing by 14.29% with the yellow filter, and being of 46.67% in the control group. With the yellow filter, the contrast threshold mean improved with glare (p=0.0479) and without glare (p=0.00012) respect the lasik group without filter. Moreover, contrast threshold differences among control and lasik group were statistically significant, obteining the control group the best contrast thresholds with glare (p?0.01) and without glare ( p=0.01) CONCLUSION: The effect of yellow filter without residual reflections had a positive influence on the mesopic ontrast perception of eyes having uncomplicated excimer laser in situ keratomileusis (LASIK) for myopia.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/108038
dc.language.isoeng
dc.rights.accessRightsopen access
dc.subject.cdu681.7.03
dc.subject.keywordcontrast sensitivity; physiological optics; image analysis.
dc.subject.ucmÓptica y optometría
dc.subject.ucmÓptica oftálmica
dc.subject.ucmÓptica geométrica e instrumental
dc.subject.ucmOftalmología
dc.subject.unesco2209 Óptica
dc.subject.unesco2209.15 Optometría
dc.subject.unesco3201.09 Oftalmología
dc.titleEffect of Yellow filter on mesopic contrast threshold with and without glare in myopia corrected by laser in situ keratomileusis (lasik).
dc.title.alternativeEfecto del filtro amarillo sobre el umbral de contraste mesópico con y sin deslumbramiento en la miopía corregida mediante queratomileusis in situ con láser (lasik).
dc.typeconference poster
dc.type.hasVersionAM
dspace.entity.typePublication
relation.isAuthorOfPublication7791e9b0-678d-49da-9010-8f913d903d58
relation.isAuthorOfPublication720db6ca-117d-4df6-9208-aa25c7832cdf
relation.isAuthorOfPublication3360352c-552e-4aab-aa7d-ec88baa8079e
relation.isAuthorOfPublication.latestForDiscovery7791e9b0-678d-49da-9010-8f913d903d58

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Effect_yellow_filter_mesopic_contrast_threshold.pdf
Size:
381.91 KB
Format:
Adobe Portable Document Format