Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Glaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study

dc.contributor.authorArriola Villalobos, Pedro
dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.contributor.authorDíaz Valle, David
dc.contributor.authorMorales Fernández, Laura
dc.contributor.authorFernández Pérez, Cristina
dc.contributor.authorGarcía Feijoo, Julián
dc.dateReceived 17 June 2016; Revised 9 September 2016; Accepted 5 October 2016
dc.date.accessioned2023-06-17T22:05:23Z
dc.date.available2023-06-17T22:05:23Z
dc.date.issued2016-11
dc.description.abstractPurpose. To evaluate the long-term efficacy and safety of the iStent inject device (Glaukos Corporation, Laguna Hills, CA) combined with phacoemulsification in patients with coexistent cataract and open-angle glaucoma or ocular hypertension (OHT). Methods. A prospective, uncontrolled, nonrandomized, interventional case series study was conducted in patients with both mild or moderate open-angle glaucoma or OHT and cataract. Patients underwent cataract surgery along with the implant of two iStent inject devices. Outcome measures were intraocular pressure (IOP), topical hypotensive medications required, and best-corrected visual acuity (BCVA). Results. 20 patients were enrolled. Mean follow-up was months. Mean baseline IOP was  mmHg with medication and  mmHg after washout. Mean end-follow-up IOP was  mmHg, representing an IOP decrease of 36.92%,  mmHg (), from baseline washout IOP. The mean number of medications was significantly reduced from to (). 45% of patients were medication-free by the end of follow-up. Mean BCVA improved significantly from to (). No complications of surgery were observed. Conclusion. The iStent inject device combined with cataract surgery served to significantly reduce both IOP and medication use in the long term in patients with coexistent open-angle glaucoma or ocular hypertension (OHT) and cataract.en
dc.description.departmentUnidad Docente de Inmunología, Oftalmología y ORL
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/44479
dc.identifier.citationArriola Villalobos, P., Martínez De La Casa Fernández-Borrella, J. M., Díaz Valle, D. et al. «Glaukos iStent Inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Study». Journal of Ophthalmology, vol. 2016, 2016, pp. 1-7. DOI.org (Crossref), https://doi.org/10.1155/2016/1056573.
dc.identifier.doi10.1155/2016/1056573
dc.identifier.issn2090-004X
dc.identifier.officialurlhttp://dx.doi.org/10.1155/2016/1056573
dc.identifier.relatedurlhttps://www.hindawi.com/journals/joph/2016/1056573/
dc.identifier.relatedurlhttps://www.ncbi.nlm.nih.gov/pubmed/27882243
dc.identifier.urihttps://hdl.handle.net/20.500.14352/18044
dc.journal.titleJournal of Ophthalmology
dc.language.isoeng
dc.page.initial7 p.
dc.publisherHINDAWI PUBLISHING CORPORATION
dc.rightsAtribución-NoComercial 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by-nc/3.0/es/
dc.subject.cdu617.741-004.1-089
dc.subject.cdu617.7-007.681
dc.subject.cdu617.7-008
dc.subject.keywordTrabecular Micro-bypass implantation
dc.subject.keywordCataract surgery
dc.subject.keywordOpen-angle glaucoma
dc.subject.keywordOcular hypertension
dc.subject.ucmCirugía
dc.subject.ucmOftalmología
dc.subject.ucmÓptica oftálmica
dc.subject.unesco3213 Cirugía
dc.subject.unesco3201.09 Oftalmología
dc.titleGlaukos iStent inject® Trabecular Micro-Bypass Implantation Associated with Cataract Surgery in Patients with Coexisting Cataract and Open-Angle Glaucoma or Ocular Hypertension: A Long-Term Studyen
dc.typejournal article
dc.volume.number2016
dspace.entity.typePublication
relation.isAuthorOfPublication302adf1a-3cda-44c0-a3bd-ef3a9418d76d
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication3e2b98e5-5c02-400b-8823-90887624c010
relation.isAuthorOfPublicatione3b551e4-0127-4a0e-ad9e-2232be67b78b
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublication.latestForDiscovery302adf1a-3cda-44c0-a3bd-ef3a9418d76d

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Glaukos-JournOpth-Hindawi-2016.pdf
Size:
1.5 MB
Format:
Adobe Portable Document Format

Collections