Interrater reliability and agreement of the NEUMOBACT checklist about infection-prevention performance of intensive care nurses in simulation-based scenarios

dc.contributor.authorRaurell Torredà, Marta
dc.contributor.authorZaragoza García, Ignacio
dc.contributor.authorArrogante Maroto, Óscar
dc.contributor.authorAliberch Raurell, Anna María
dc.contributor.authorSánchez Chillón, Francisco Javier
dc.contributor.authorTorralba Melero, Martín
dc.contributor.authorRojo Rojo, Andrés
dc.contributor.authorMuriel García, Alfonso
dc.contributor.authorAmaya Arias, Ana Carolina
dc.contributor.authorRoldán Merino, Juan
dc.contributor.authorFarrés Tarafa, Mariona
dc.date.accessioned2025-04-29T17:37:52Z
dc.date.available2025-04-29T17:37:52Z
dc.date.issued2024-12-31
dc.description.abstractObjective To analyse the interrater reliability of the NEUMOBACT checklist and verify whether consistent results are reproducible. Methods A validation study with a cross-sectional design, compliant with the GRRAS checklist, among ICU nurses attending a SIMULAZERO course with an Objective Structured Clinical Evaluation simulation format, to verify transfer from theory to clinical practice of knowledge and skills in ventilator-associated pneumonia (VAP) and catheter-related bacteraemia (CRB) prevention. A minimum sample size of 111 pairs of nurse raters was calculated. Interrater agreement was analysed using Gwet’s AC1 for each item and as a total for each of the three checklists in the NEUMOBACT instrument. Results A total of 95 pairs of valid NEUMOBACT checklists were completed by 190 raters with a median age of 29 [25–35] years, 93.7% were female. At the Central Venous Catheter insertion station, Gwet’s AC1 was 0.934 (95% CI [0.919–0.949]). Only 2 of the 17 items scored below 0.9. At the Endotracheal Suctioning station, Gwet’s AC1 was 0.869 (95% CI [0.851–0.886]). Of the 26 items that made up this station, 16 had an agreement percentage above 0.9, a further 9 were between 0.821 and 0.884, and item 13 had a value of 0.789. At the Patient Care station, Gwet’s AC1 was 0.911 (95% CI [0.896–0.927]). Of the 21 items, 17 showed an agreement percentage above 0.9 and 4 were between 0.810 and 0.894. Conclusions The interrater reliability of the NEUMOBACT checklist shows substantial agreement between pairs of raters and is therefore validated in this large sample of ICU nurses. Relevance to clinical practice The NEUMOBACT checklist can be useful for assessing skills before and after training in VAP and CRB prevention measures and during debriefing (post-simulation feedback), to reinforce the scientific evidence behind actions and decisions for items that have been performed incorrectly, thus consolidating training already received.
dc.description.departmentDepto. de Enfermería
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.sponsorshipSociedad Española de Simulación Clínica y Seguridad del Paciente
dc.description.statuspub
dc.identifier.citationRaurell-Torredà, M., Zaragoza-García, I., Arrogante, O., Aliberch-Raurell, A. M., Sánchez-Chillón, F. J., Torralba-Melero, M., Rojo-Rojo, A., Muriel-García, A., Arias, A. C. A., Roldán-Merino, J., & Farrés-Tarafa, M. (2024). Interrater reliability and agreement of the NEUMOBACT checklist about infection-prevention performance of intensive care nurses in simulation-based scenarios. PLoS ONE, 19(12 December). https://doi.org/10.1371/JOURNAL.PONE.0313175
dc.identifier.doi10.1371/journal.pone.0313175
dc.identifier.issn1932-6203
dc.identifier.officialurlhttps://doi.org/10.1371/journal.pone.0313175
dc.identifier.relatedurlhttps://journals.plos.org/plosone/article?id=10.1371/journal.pone.0313175
dc.identifier.urihttps://hdl.handle.net/20.500.14352/119768
dc.issue.number12
dc.journal.titlePLoS ONE
dc.language.isoeng
dc.page.final12
dc.page.initial1
dc.publisherPublic Library of Science
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu616-083
dc.subject.ucmEnfermería
dc.subject.unesco3299 Otras Especialidades Médicas
dc.titleInterrater reliability and agreement of the NEUMOBACT checklist about infection-prevention performance of intensive care nurses in simulation-based scenarios
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number19
dspace.entity.typePublication
relation.isAuthorOfPublication61989576-46c1-456c-bca0-73cd8e2581a3
relation.isAuthorOfPublicationdf0c23ce-6f34-41b2-87d1-c30ef3581281
relation.isAuthorOfPublication0957c323-2ff1-47e5-b530-a3a769cbe7cd
relation.isAuthorOfPublication.latestForDiscovery61989576-46c1-456c-bca0-73cd8e2581a3

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Interrater_reliability.pdf
Size:
522.78 KB
Format:
Adobe Portable Document Format

Collections