Three-dimensional measurement of microchips using structured light techniques
| dc.contributor.author | Quiroga Mellado, Juan Antonio | |
| dc.contributor.author | Vargas Balbuena, Javier | |
| dc.contributor.author | Koninckx, Thomas | |
| dc.contributor.author | Van Gool, Luc | |
| dc.date.accessioned | 2023-06-20T10:37:02Z | |
| dc.date.available | 2023-06-20T10:37:02Z | |
| dc.date.issued | 2008-05 | |
| dc.description | © 2008 Society of Photo-Optical Instrumentation Engineers. | |
| dc.description.abstract | The industry dealing with microchip inspection requires fast, flexible, repeatable, and stable 3-D measuring systems. The typical devices used for this purpose are coordinate measurement machines (CMMs). These systems have limitations such as high cost, low measurement speed, and small quantity of measured 3-D points. Now optical techniques are beginning to replace the typical touch probes because of their noncontact nature, their full-field measurement capability, their high measurement density, as well as their low cost and high measurement speed. However, typical properties of microchip devices, which include a strongly spatially varying reflectance, make impossible the direct use of the classical optical 3-D measurement techniques. We present a 3-D measurement technique capable of optically measuring these devices using a camera-projector system. The proposed method improves the dynamic range of the imaging system through the use of a set of gray-code (GC) and phase- shift (PS) measures with different CCD integration times. A set of extended-range GC and PS images are obtained and used to acquire a dense 3-D measure of the object. We measure the 3-D shape of an integrated circuit and obtained satisfactory results. | |
| dc.description.department | Depto. de Óptica | |
| dc.description.faculty | Fac. de Ciencias Físicas | |
| dc.description.refereed | TRUE | |
| dc.description.status | pub | |
| dc.eprint.id | https://eprints.ucm.es/id/eprint/22891 | |
| dc.identifier.doi | 10.1117/1.2919726 | |
| dc.identifier.issn | 0091-3286 | |
| dc.identifier.officialurl | http://dx.doi.org/10.1117/1.2919726 | |
| dc.identifier.relatedurl | http://opticalengineering.spiedigitallibrary.org | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14352/50784 | |
| dc.issue.number | 5 | |
| dc.journal.title | Optical Engineering | |
| dc.publisher | Spie-Soc Photo-Optical Instrumentation Engineers | |
| dc.rights.accessRights | metadata only access | |
| dc.subject.cdu | 535 | |
| dc.subject.keyword | Calibration | |
| dc.subject.keyword | High Dynamic-Range Imaging | |
| dc.subject.keyword | Active Three-Dimensional Measure | |
| dc.subject.keyword | Microchip Inspection | |
| dc.subject.ucm | Óptica (Física) | |
| dc.subject.unesco | 2209.19 Óptica Física | |
| dc.title | Three-dimensional measurement of microchips using structured light techniques | |
| dc.type | journal article | |
| dc.volume.number | 47 | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 1c171089-8e25-448f-bcce-28d030f8f43a | |
| relation.isAuthorOfPublication | 6ccb1e60-8b61-4b23-8a0a-09af30f7b795 | |
| relation.isAuthorOfPublication.latestForDiscovery | 1c171089-8e25-448f-bcce-28d030f8f43a |