Para depositar en Docta Complutense, identifícate con tu correo @ucm.es en el SSO institucional. Haz clic en el desplegable de INICIO DE SESIÓN situado en la parte superior derecha de la pantalla. Introduce tu correo electrónico y tu contraseña de la UCM y haz clic en el botón MI CUENTA UCM, no autenticación con contraseña.

Heat and mass transfer in vacuum membrane distillation

Loading...
Thumbnail Image

Full text at PDC

Publication date

2004

Advisors (or tutors)

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier
Citations
Google Scholar

Citation

Abstract

In the membrane distillation (MD) literature, the heat transfer coefficients of the boundary layers are usually estimated from well known heat transfer empirical correlations developed for non-porous and rigid heat exchangers. A difference between the mechanism of heat transfer in MD systems, which is coupled with transmembrane mass transfer, and the mechanism of heat transfer in "pure" heat exchangers is expected to exist. Vacuum membrane distillation has been experimentally studied in a capillary membrane module and the heat transfer coefficients have been evaluated in both the lumen and the shell side of the membrane module. A critical review of the most frequently used heat transfer empirical correlations in MD systems is presented. Finally, the experimental results obtained in this paper are compared to those of literature, in order to test their applicability in membrane distillation systems.

Research Projects

Organizational Units

Journal Issue

Description

© 2003 Elsevier Ltd. Economical support from the CICYT is acknowledged.