Direct proton range verification using oxygen-18 enriched water as a contrast agent
dc.contributor.author | España Palomares, Samuel | |
dc.contributor.author | Sánchez Parcerisa, Daniel | |
dc.contributor.author | Ibáñez García, Paula Beatriz | |
dc.contributor.author | Sánchez Tembleque Verbo, Víctor | |
dc.contributor.author | Udías Moinelo, José Manuel | |
dc.contributor.author | Valladolid Onecha, Víctor | |
dc.contributor.author | Gutiérrez Uzquiza, Álvaro | |
dc.contributor.author | Bäcker, Claus Maximilian | |
dc.contributor.author | Bäumer, Christian | |
dc.contributor.author | Herrmann, Ken | |
dc.contributor.author | Fragoso Costa, Pedro | |
dc.contributor.author | Timmermann, Beate | |
dc.contributor.author | Fraile Prieto, Luis Mario | |
dc.date.accessioned | 2023-06-17T08:22:27Z | |
dc.date.available | 2023-06-17T08:22:27Z | |
dc.date.issued | 2021-02-08 | |
dc.description | CRUE-CSIC (Acuerdos Transformativos 2021) | |
dc.description.abstract | We propose the use of O-enriched water as a suitable contrast agent for potential in-vivo range verification in proton therapy. The low energy production threshold of 18F (2.6 MeV, proton range in water of 115 μm) leads to tissue activation in very close proximity to the maximum dose deposition, facilitating accurate range verification with off-line PET imaging. This idea has been explored in a phantom experiment. A 3D-printed phantom containing inserts with 18Oenriched water was irradiated with a 100-MeV, 8 × 8 cm2 proton beam, and the induced activity was measured with a small-animal PET-CT 30 min after irradiation. The images obtained were compared against Monte Carlo simulation using TOPAS. Good agreement was observed between reconstructed and simulated activity profiles (within 40% for specific 18F activity), with excellent spatial match to the simulated dose deposition. Because of the long half-life of 18F, the specific activity of the contrast agent could be separated and was clearly observed for more than 2 h after irradiation. Activity distribution maps were used to determine the position of the Bragg peak within 2 mm for three different regions of interest. These results show the potential of 18O-enriched water as a contrast agent in proton therapy. | en |
dc.description.department | Depto. de Estructura de la Materia, Física Térmica y Electrónica | |
dc.description.department | Sección Deptal. de Bioquímica y Biología Molecular (Farmacia) | |
dc.description.faculty | Fac. de Ciencias Físicas | |
dc.description.faculty | Fac. de Farmacia | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Unión Europea | |
dc.description.sponsorship | Ministerio de Ciencia, Innovación y Universidades (España) | |
dc.description.sponsorship | Comunidad de Madrid | |
dc.description.sponsorship | Comunidad de Madrid/Fondo Europeo de Desarrollo Regional | |
dc.description.sponsorship | Centro de Excelencia Severo Ochoa | |
dc.description.sponsorship | Universidad Complutense de Madrid | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/70592 | |
dc.identifier.citation | España Palomares, S., Sánchez Parcerisa, D., Ibáñez García, P. B. et al. «Direct Proton Range Verification Using Oxygen-18 Enriched Water as a Contrast Agent». Radiation Physics and Chemistry, vol. 182, mayo de 2021, p. 109385. DOI.org (Crossref), https://doi.org/10.1016/j.radphyschem.2021.109385. | |
dc.identifier.doi | 10.1016/j.radphyschem.2021.109385 | |
dc.identifier.issn | 0969-806X | |
dc.identifier.officialurl | https://doi.org/10.1016/j.radphyschem.2021.109385 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/6831 | |
dc.journal.title | Radiation Physics and Chemistry | |
dc.language.iso | eng | |
dc.page.initial | 109385 | |
dc.publisher | Elsevier | |
dc.relation.projectID | CAPPERAM (793576) | |
dc.relation.projectID | (RTI 2018-098868- B-I00, RTC-2015-3772-1) | |
dc.relation.projectID | PRONTO-CM (B2017/BMD-3888); TOPUS-CM (S2013/MIT-3024) | |
dc.relation.projectID | (2016-T1/TIC-1099). | |
dc.relation.projectID | UCM (910059) | |
dc.relation.projectID | (SEV-2015-0505). | |
dc.relation.projectID | info:eu-repo/grantAgreement/EC/H2020/Number of agreement | |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | |
dc.rights.accessRights | open access | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/3.0/es/ | |
dc.subject.keyword | 18O | |
dc.subject.keyword | Phantom | |
dc.subject.keyword | Activation | |
dc.subject.keyword | Range verification | |
dc.subject.keyword | Protontherapy | |
dc.subject.ucm | Física (Física) | |
dc.subject.ucm | Física nuclear | |
dc.subject.unesco | 22 Física | |
dc.subject.unesco | 2207 Física Atómica y Nuclear | |
dc.title | Direct proton range verification using oxygen-18 enriched water as a contrast agent | en |
dc.type | journal article | |
dc.volume.number | 182 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | e1626638-37c9-49cb-ac6c-dc1e2a820b3a | |
relation.isAuthorOfPublication | d228b73c-ba3b-487d-91bd-5f4e22cf9c00 | |
relation.isAuthorOfPublication | 3e87aa6b-a8b0-482e-99ba-f8afc04e5340 | |
relation.isAuthorOfPublication | fbe547a8-b013-4759-9a1f-a9df96a3f7c4 | |
relation.isAuthorOfPublication | 3dc23e23-6e7e-47dd-bd61-8b6b7a1ad75f | |
relation.isAuthorOfPublication | bc4c2922-3f49-4ac1-a2f1-ba6eb6acb851 | |
relation.isAuthorOfPublication | fe7d7e09-f48f-4104-b627-5f056790b029 | |
relation.isAuthorOfPublication | ec83106c-33f4-426c-afd6-68c5d859f9d4 | |
relation.isAuthorOfPublication.latestForDiscovery | e1626638-37c9-49cb-ac6c-dc1e2a820b3a |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- 1-s2.0-S0969806X21000359-main.pdf
- Size:
- 5.98 MB
- Format:
- Adobe Portable Document Format