Electrochemical biosensor for the simultaneous determination of rheumatoid factor and anti-cyclic citrullinated peptide antibodies in human serum
| dc.contributor.author | Guerrero Irigoyen, Sara | |
| dc.contributor.author | Sánchez Tirado, Esther | |
| dc.contributor.author | Martínez-García, Gonzalo | |
| dc.contributor.author | González Cortés, Araceli | |
| dc.contributor.author | Yáñez-Sedeño Orive, Paloma | |
| dc.contributor.author | Pingarrón Carrazón, José Manuel | |
| dc.date.accessioned | 2024-01-25T10:32:33Z | |
| dc.date.available | 2024-01-25T10:32:33Z | |
| dc.date.issued | 2020 | |
| dc.description.abstract | This paper reports a dual electrochemical biosensor involving carboxylated- or neutravidin-functionalized magnetic microbeads and dual screen-printed carbon electrodes for the simultaneous determination of rheumatoid factor (RF) and anti-cyclic citrullinated peptide (CCPA) autoantibodies used as biomarkers for the detection of rheumatoid arthritis autoimmune disease. Sandwich-type biosensors involving Fc fragments of IgG Fc(IgG) and biotinylated cyclic cytrullinated peptide (CCP-biotin) to form CCP-biotin-Neutr-MBs for the specific immobilization of RF and CCPA, respectively, as well as conjugation with HRP-IgM and HRP-IgG for RF and CCPA, respectively, were prepared. Amperometric detection was performed at −0.20 V vs. Ag pseudo-reference electrode using the H2O2/hydroquinone (HQ) system upon capturing the bioconjugates onto the corresponding working electrode (WE1 or WE2) of SPCdEs. The dual biosensor exhibits high sensitivity for RF and CCPA with LOD values of 0.8 and 2.5 IU mL−1, respectively. The simultaneous determination can be completed in about two hours using a simple protocol and a sample volume (25 μL) four times smaller than that required by the ELISA method. The dual electrochemical biosensor was used for the determination of both target biomarkers in human serum. | |
| dc.description.department | Depto. de Química Analítica | |
| dc.description.faculty | Fac. de Ciencias Químicas | |
| dc.description.refereed | TRUE | |
| dc.description.sponsorship | Ministerio de Economía y Competitividad (España) | |
| dc.description.sponsorship | Ministerio de Ciencia, Innovación y Universidades (España) | |
| dc.description.sponsorship | Comunidad de Madrid | |
| dc.description.status | pub | |
| dc.identifier.citation | Guerrero S, Sánchez-Tirado E, Martínez-García G, González-Cortés A, Yáñez-Sedeño P, Pingarrón J.M. Electrochemical biosensor for the simultaneous determination of rheumatoid factor and anti-cyclic citrullinated peptide antibodies in human serum. Analyst 2020 May 22;145(13):4680-87 | |
| dc.identifier.doi | 10.1039/D0AN00481B | |
| dc.identifier.issn | 0003-2654 | |
| dc.identifier.officialurl | https://www.doi.org/10.1039/D0AN00481B | |
| dc.identifier.relatedurl | https://pubs.rsc.org/en/content/articlelanding/2020/an/d0an00481b | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14352/95335 | |
| dc.issue.number | 13 | |
| dc.journal.title | Analyst | |
| dc.language.iso | eng | |
| dc.page.final | 4687 | |
| dc.page.initial | 4680 | |
| dc.publisher | Royal Society of Chemistry | |
| dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//CTQ2015-64402-C2-1-R/ES/NUEVAS PLATAFORMAS DE MULTIPLEXADO ELECTROANALITICAS PARA LA DETECCION Y PRONOSTICO DE ENFERMEDADES NEOPLASICAS MEDIANTE BIOPSIAS LIQUIDAS/ | |
| dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RTI2018-096135-B-I00/ES/PLATAFORMAS ELECTROQUIMICAS INMUNOSENSORAS PARA AUTOANTICUERPOS Y ANTIGENOS PROTEINICOS DE RELEVANCIA EMERGENTE EN ENFERMEDADES AUTOINMUNES/ | |
| dc.relation.projectID | S2018/NMT-4349 | |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | en |
| dc.rights.accessRights | metadata only access | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject.cdu | 543 | |
| dc.subject.keyword | Electrochemical immunosensor | |
| dc.subject.keyword | Rheumatoid factor | |
| dc.subject.keyword | Anti-cyclic citrullinated peptide | |
| dc.subject.keyword | Magnetic microbeads | |
| dc.subject.keyword | Human serum | |
| dc.subject.ucm | Química analítica (Química) | |
| dc.subject.unesco | 2301.04 Análisis Electroquímico | |
| dc.subject.unesco | 2301 Química Analítica | |
| dc.title | Electrochemical biosensor for the simultaneous determination of rheumatoid factor and anti-cyclic citrullinated peptide antibodies in human serum | |
| dc.type | journal article | |
| dc.volume.number | 145 | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 746c8c8c-1e81-4897-8b4f-bfb1ff9d741a | |
| relation.isAuthorOfPublication | 8ce0e95b-049c-4147-be76-110e258443a1 | |
| relation.isAuthorOfPublication | 8a730734-cdf5-4b59-b017-12e2320c872e | |
| relation.isAuthorOfPublication | 06ab2fa0-2b2d-4b58-80ed-82f9cc767175 | |
| relation.isAuthorOfPublication | 8808f99c-5f56-4562-839a-517626c76dad | |
| relation.isAuthorOfPublication.latestForDiscovery | 746c8c8c-1e81-4897-8b4f-bfb1ff9d741a |

