Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: a systematic review

dc.contributor.authorGómez Polo, Miguel Ángel
dc.contributor.authorBorga Donmez, Mustafa
dc.contributor.authorÇakmak, Gülce
dc.contributor.authorYilmaz, Burak
dc.contributor.authorRevilla León, Marta
dc.date.accessioned2024-01-19T13:21:34Z
dc.date.available2024-01-19T13:21:34Z
dc.date.issued2023-09-28
dc.description.abstractPurpose: To evaluate the influence of implant scan body (ISB) design (height, diameter, geometry, material, and retention system) on the accuracy of digital implant scans. Material and methods: A literature search was completed in five databases: PubMed/Medline, Scopus, Embase, World of Science, and Cochrane. A manual search was also conducted. Studies reporting the evaluation of ISB design on the accuracy of digital scans obtained by using IOSs were included. Two investigators evaluated the studies independently by applying the Joanna Briggs Institute critical appraisal. A third examiner was consulted to resolve any lack of consensus. Articles were classified based on the ISB features of height, geometry, material, and retention system. Results: Twenty articles were included. Among the reviewed studies, 11 investigations analyzed the influence of different ISB geometries, 1 study assessed the impact of ISB diameter, 4 studies investigated the effect of ISB splinting, 2 articles evaluated ISB height, and 2 studies focused on the effect of ISB material on scan accuracy. In addition, 8 studies involved ISBs fabricated with different materials (1- and 2-piece polyetheretherketone and 1-piece titanium ISBs), and all of the reviewed articles tested screw-retained ISBs, except for 3 in vitro studies. Conclusions: The findings did not enable concrete conclusions regarding the optimal ISB design, whether there is a relationship between IOS technology and a specific ISB design, or the clinical condition that maximizes intraoral scanning accuracy. Research efforts are needed to identify the optimal ISB design and its possible relationship with the IOS selected for acquiring intraoral digital implant scans.en
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationGómez-Polo M, Donmez MB, Çakmak G, Yilmaz B, Revilla-León M. Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: A systematic review. J Prosthodont. 2023 Dec;32(S2):165-180
dc.identifier.doi10.1111/jopr.13774
dc.identifier.essn1532-849X
dc.identifier.issn1059-941X
dc.identifier.officialurlhttps//doi.org/10.1111/jopr.13774
dc.identifier.pmid37771200
dc.identifier.relatedurlhttps://onlinelibrary.wiley.com/doi/pdfdirect/10.1111/jopr.13774
dc.identifier.urihttps://hdl.handle.net/20.500.14352/94075
dc.issue.numberS2
dc.journal.titleJournal of Prosthodontics
dc.language.isoeng
dc.page.final180
dc.page.initial165
dc.publisherWiley
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.cdu616.314
dc.subject.cdu616.314-089.843
dc.subject.cdu616.314-089.28
dc.subject.cdu616-073.75
dc.subject.keywordAccuracy
dc.subject.keywordDigital impression
dc.subject.keywordImplant scan body
dc.subject.keywordProsthodontics
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmImplantes dentales
dc.subject.ucmPrótesis dental
dc.subject.ucmAparatos y material odontológicos
dc.subject.unesco32 Ciencias Médicas
dc.subject.unesco3201 Ciencias Clínicas
dc.subject.unesco3311.03 Instrumentos Para Odontología
dc.titleInfluence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: a systematic reviewen
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number32
dspace.entity.typePublication
relation.isAuthorOfPublication9700c70b-34f2-4d6a-8e12-92587c9186fb
relation.isAuthorOfPublication.latestForDiscovery9700c70b-34f2-4d6a-8e12-92587c9186fb

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: a systematic review
Size:
610.03 KB
Format:
Adobe Portable Document Format

Collections