Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA Disculpen las molestias.
 

Forward light scatter and visual acuity before and after intrastromal corneal ring segment implantation at different stages of keratoconus

dc.contributor.authorPuell Marín, María Cinta
dc.contributor.authorCarballo Álvarez, Jesús
dc.date.accessioned2023-06-17T21:58:51Z
dc.date.available2023-06-17T21:58:51Z
dc.date.issued2016-12
dc.descriptionManuscript Received: 18 November 2015; Manuscript Accepted: 15 February 2016; Issue online: 21 November 2016.
dc.description.abstractPurpose: to assess forward light scatter (stray light) before and after intrastromal corneal ring segment (ICRS) implantation at different stages of keratoconus and to examine correlation between postoperative stray light and visual acuity (VA). Methods: in 27 eyes of 27 subjects with keratoconus, stray light was determined using the compensation comparison technique before and 6 months after ICRS implantation. Monocular corrected distance VA (CDVA) was measured using a high-contrast logMAR letter chart. Corneal higher-order aberrations (HOAs), contrast sensitivity (CS) and minimum corneal thickness (CT) were also measured. Results: mean CDVA was 0.42 ± 0.28 preoperatively and 0.24 ± 0.15 logMAR postoperatively (p < 0.01). Mean corneal coma-like aberration decreased postoperatively (RMS 0.55 ± 1.18 μm, p < 0.01). Minimum CT increased 25.31 ± 18.59 μm (p < 0.01). Mean preoperative and postoperative stray light were 1.36 ± 0.31 and 1.48 ± 0.32 log units, respectively (p < 0.01). Mean changes produced in stray light (worsening) were 0.03 ± 0.21 (p > 0.05) for stage I, 0.13 ± 0.14 (p = 0.013) for stage II and 0.18 ± 0.21 (p = 0.023) for stage III. Significant positive correlation (r = 0.47, p = 0.01) was detected between postoperative stray light and postoperative CDVA such that as stray light increased, CDVA worsened (higher logMAR values). Postoperative stray light was neither associated with HOAs, CS nor minimum CT. Conclusions: stray light values in these patients with keratoconus were higher than normal preoperatively. In eyes with stage II and III keratoconus, stray light increased 6 months after ICRS placement. Higher postoperative stray light was correlated with a worse visual acuity outcome.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/43546
dc.identifier.doi10.1111/aos.13056
dc.identifier.issn1755-375X
dc.identifier.officialurlhttp://dx.doi.org/10.1111/aos.13056
dc.identifier.relatedurlhttps://www.ncbi.nlm.nih.gov/pubmed/27129433
dc.identifier.urihttps://hdl.handle.net/20.500.14352/17882
dc.issue.number8
dc.journal.titleActa Ophthalmologica
dc.language.isoeng
dc.page.final743
dc.page.initial738
dc.publisherJohn Wiley & Sons Ltd.
dc.rights.accessRightsrestricted access
dc.subject.cdu617.713-089
dc.subject.cdu617.751
dc.subject.keywordforward scatter
dc.subject.keywordintrastromal corneal ring segment
dc.subject.keywordkeratoconus
dc.subject.keywordstray light
dc.subject.keywordvisual acuity
dc.subject.ucmOftalmología
dc.subject.ucmOptometría
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco2209.15 Optometría
dc.titleForward light scatter and visual acuity before and after intrastromal corneal ring segment implantation at different stages of keratoconus
dc.typejournal article
dc.volume.number94
dspace.entity.typePublication
relation.isAuthorOfPublication720db6ca-117d-4df6-9208-aa25c7832cdf
relation.isAuthorOfPublicationd90c8dc9-5aef-4047-950e-c6c59469ec3f
relation.isAuthorOfPublication.latestForDiscovery720db6ca-117d-4df6-9208-aa25c7832cdf

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Puell_et_al-2016-Acta_Ophthalmologica.pdf
Size:
175.8 KB
Format:
Adobe Portable Document Format

Collections