Análisis del segmento intermedio ocular mediante tomografía de coherencia óptica swept source

dc.contributor.advisorFernández-Vigo Escribano, José Ignacio
dc.contributor.advisorFernández-Vigo López, José
dc.contributor.advisorMartínez De La Casa Fernández-Borrella, José María
dc.contributor.authorFernández Aragón, Susana
dc.date.accessioned2025-08-19T13:55:51Z
dc.date.available2025-08-19T13:55:51Z
dc.date.defense2025
dc.date.issued2025
dc.descriptionTesis inédita de la Universidad Complutense de Madrid, Facultad de Medicina, leída el 24/01/2025
dc.description.abstractEvaluar las dimensiones del segmento intermedio ocular in vivo mediante la tomografía de coherencia óptica swept-source (OCT-SS) según la raza (hispanoamericanos y caucásicos) y según el defecto refractivo (miopes magnos (MM) y emétropes), analizándose además la reproducibilidad de las medidas. Por último, se estudió la correlación entre las dimensiones del segmento intermedio y otras variables como la edad, EE (equivalente esférico), PIO (presión intraocular) y sexo. Método: Estudio transversal unicéntrico, en el que se evaluaron las dimensiones del segmento intermedio ocular: espesor de conjuntiva-Tenon (CCT), espesor de esclera anterior (AST), espesor del músculo ciliar (CMT) y longitud del músculo ciliar (CML). Las medidas se realizaron manualmente en los cuadrantes nasal y temporal, a una distancia de 1, 2 y 3 mm desde el espolón escleral (SS) empleando la OCT-SS DRI- Triton® (Topcon, Tokyo, Japón). Se analizó la correlación de las dimensiones del segmento intermedio con factores como la edad, EE y PIO. La reproducibilidad de las medidas fue estudiada en una muestra de sujetos hispanoamericanos elegidos al azar... To evaluate the dimensions of the ocular intermediate segment in vivo using swept-source optical coherence tomography (OCT-SS) according to race (Hispanic and Caucasian) and refractive error (high myopia (HM) and emmetropic), also analyzing the reproducibility of the measurements. Lastly, the correlation between ocular intermediate segment dimensions and other variables such as age, spherical equivalent (SE), intraocular pressure (IOP), and gender was studied.Method: A unicentric cross-sectional study was conducted to evaluate the dimensions of the ocular intermediate segment: conjunctiva-Tenon thickness (CCT), anterior sclera thickness (AST), ciliary muscle thickness (CMT), ciliary muscle length (CML). Measurements were performed manually in the nasal and temporal quadrants, at distances of 1, 2, and 3 mm from the scleral spur (SS) using the OCT-SS DRI- Triton® (Topcon, Tokyo, Japan). The correlation of the intermediate segment dimensions with factors such as age, SE, and IOP was analyzed. The reproducibility of the measurements was studied in a randomly selected sample of Hispanics subjects...
dc.description.facultyFac. de Medicina
dc.description.refereedTRUE
dc.description.statusunpub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/123240
dc.language.isospa
dc.page.total251
dc.publication.placeMadrid
dc.publisherUniversidad Complutense de Madrid
dc.rights.accessRightsopen access
dc.subject.cdu617.7(043.2)
dc.subject.ucmOftalmología
dc.subject.ucmTécnicas de la imagen
dc.subject.ucmAnatomía ocular
dc.subject.unesco2209 Óptica
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco2410.12 Anatomía Sistemática
dc.titleAnálisis del segmento intermedio ocular mediante tomografía de coherencia óptica swept source
dc.typedoctoral thesis
dspace.entity.typePublication
relation.isAdvisorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAdvisorOfPublication.latestForDiscovery273a99c3-2c9f-4dd0-8939-b7ff3593124c

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
T45603.pdf
Size:
3.79 MB
Format:
Adobe Portable Document Format

Collections