Porcine Model to Evaluate Real-Time Intraocular Pressure During Femtosecond Laser Cataract Surgery

dc.contributor.authorIbarz, Marta
dc.contributor.authorHernández Verdejo, José Luis
dc.contributor.authorBolívar de Miguel, Gema
dc.contributor.authorTañá Rivero, Pedro
dc.contributor.authorRodríguez Prats, José Luis
dc.contributor.authorTeus Guezala, Miguel Ángel
dc.date.accessioned2023-06-18T05:45:54Z
dc.date.available2023-06-18T05:45:54Z
dc.date.issued2016
dc.descriptionReceived 28 Oct 2014, Accepted 22 Feb 2015, Published online: 27 May 2015
dc.description.abstractPurpose: To investigate the changes in intraocular pressure (IOP) in porcine eyes during femtosecond laser-assisted cataract surgery using a liquid-optic interface system. Materials and methods: Femtosecond laser cataract surgery with the Catalys™ was performed on freshly enucleated porcine eyes in Oftalvist Moncloa, Madrid, Spain. Capsulorhexis and lens fragmentation were completed in all the eyes without complications. IOP was measured with a reusable blood pressure transducer connected by direct cannulation to the anterior chamber, recording data before suction (basal), at the beginning of the suction phase, every five seconds during femtosecond procedure and after the removal of the suction ring from the eye. Results: Nine porcine eyes were used in this study. Basal IOP before suction was 5.67 ± 2.39 mmHg, rising to 20.33 ± 4.18 mmHg at the beginning of the suction phase (p < 0.001). During femtosecond procedure, pressure reached a value of 19.74 ± 4.31 mmHg, remaining stable during the entire process. The IOP recorded prior to removal of the suction ring was 21.00 ± 6.93 mmHg, returning to basal values in all the eyes after the suction ring was removed, with no statistical differences between basal and post-suction IOPs. Total femtosecond procedure time was 125.9 ±  15.9 s. Conclusions: Real-time IOP can be measured during surgery using a transducer connected to the anterior chamber. The results showed a significant increase in IOP during the procedure due to the pressure exerted by the suction ring but not by the effect of the femtosecond laser.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/42267
dc.identifier.doi10.3109/02713683.2015.1023459
dc.identifier.issn0271-3683
dc.identifier.officialurlhttp://dx.doi.org/10.3109/02713683.2015.1023459
dc.identifier.urihttps://hdl.handle.net/20.500.14352/23278
dc.issue.number4
dc.journal.titleCurrent Eye Research
dc.language.isoeng
dc.page.final512
dc.page.initial507
dc.publisherTaylor & Francis
dc.rights.accessRightsrestricted access
dc.subject.cdu617.741-004.1
dc.subject.cdu612.842.6
dc.subject.cdu617.7:535.374
dc.subject.keywordCataract
dc.subject.keywordFemtosecond laser
dc.subject.keywordIntraocular pressure
dc.subject.keywordPorcine model
dc.subject.ucmOftalmología
dc.subject.ucmLáseres
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco2209.10 Láseres
dc.titlePorcine Model to Evaluate Real-Time Intraocular Pressure During Femtosecond Laser Cataract Surgery
dc.typejournal article
dc.volume.number41
dspace.entity.typePublication
relation.isAuthorOfPublication2ed110d3-f335-4688-9c14-1a56e56e8d28
relation.isAuthorOfPublication.latestForDiscovery2ed110d3-f335-4688-9c14-1a56e56e8d28

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Porcine Model to Evaluate Real Time Intraocular Pressure During Femtosecond Laser Cataract Surgery.pdf
Size:
746.41 KB
Format:
Adobe Portable Document Format

Collections