Visual Outcomes of a Non-Diffractive Extended Depth-of-Focus Intraocular Lens in Patients with Early-Stage Age-Related Macular Degeneration
| dc.contributor.author | Dorronzoro Ramirez, Emilio | |
| dc.contributor.author | Sánchez Tena, Miguel Ángel | |
| dc.contributor.author | Álvarez Peregrina, Cristina | |
| dc.contributor.author | Cárdenas Rebollo, José Miguel | |
| dc.contributor.author | Flores Cervantes, Dayan | |
| dc.contributor.author | Sánchez Ramos, Celia | |
| dc.date.accessioned | 2025-09-24T12:36:00Z | |
| dc.date.available | 2025-09-24T12:36:00Z | |
| dc.date.issued | 2025-08 | |
| dc.description.abstract | Background/Objectives: Age-related macular degeneration (AMD) is a leading cause of visual impairment in older adults and often coexists with cataracts. The indication of presbyopia-correcting intraocular lenses (IOLs) in these patients remains controversial. This study aimed to evaluate the clinical performance of a non-diffractive extended depth-of-focus (EDOF) IOL (LuxSmart™) compared to a monofocal plus IOL (Tecnis Eyhance™) in cataract patients with early-stage dry AMD. Methods: In this prospective observational study, 41 patients with early-stage AMD underwent bilateral cataract surgery with either LuxSmart™ or Tecnis Eyhance™ IOL implantation, targeting postoperative emmetropia. The eye selected for analysis was the first eye scheduled for surgery. Preoperative and postoperative evaluations included high and low-contrast distance visual acuity, intermediate and near visual acuity, defocus curves, ocular light scatter (halometry), and quality of life assessment (NEI VFQ-25). Postoperative biometric accuracy and refractive outcomes were also analyzed. Results: Both IOLs showed high refractive accuracy, with 100% of eyes within ±0.50 D of target. Postoperative uncorrected distance visual acuity was 0.10 ± 0.06 LogMAR for Eyhance and 0.07 ± 0.02 for LuxSmart (p = 0.06). Low contrast VA at 20% was 0.22 ± 0.11 (Eyhance) and 0.26 ± 0.16 (LuxSmart) (p = 0.49). Depth of focus was approximately 1.75 D for both lenses. Light scatter (LDI) improved postoperatively in both groups with no significant differences (p = 0.54). VFQ-25 scores showed improvement in daily activities, though no changes were observed in driving or mental health domains. Conclusions: Both lenses are safe and effective options for early AMD patients undergoing cataract surgery, providing good functional vision at multiple distances. | |
| dc.description.department | Depto. de Optometría y Visión | |
| dc.description.faculty | Fac. de Óptica y Optometría | |
| dc.description.refereed | TRUE | |
| dc.description.status | pub | |
| dc.identifier.citation | Dorronzoro-Ramirez E, Sanchez-Tena MA, Alvarez-Peregrina C, Cardenas Rebollo JM, Flores Cervantes D, Sánchez-Ramos C. Visual Outcomes of a Non-Diffractive Extended Depth-of-Focus Intraocular Lens in Patients with Early-Stage Age-Related Macular Degeneration. J Clin Med. 2025 Aug 23;14(17):5953. doi: 10.3390/jcm14175953. PMID: 40943713; PMCID: PMC12429355. | |
| dc.identifier.doi | 10.3390/jcm14175953 | |
| dc.identifier.officialurl | https://doi.org/10.3390/jcm14175953 | |
| dc.identifier.pmid | 40943713 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14352/124279 | |
| dc.issue.number | 17 | |
| dc.journal.title | Journal of Clinical Medicine | |
| dc.language.iso | eng | |
| dc.page.initial | 5953 | |
| dc.publisher | MDPI | |
| dc.rights | Attribution-ShareAlike 4.0 International | en |
| dc.rights.accessRights | open access | |
| dc.rights.uri | http://creativecommons.org/licenses/by-sa/4.0/ | |
| dc.subject.cdu | 617.7-089.243 | |
| dc.subject.keyword | LuxSmart | |
| dc.subject.keyword | Tecnis Eyhance | |
| dc.subject.keyword | Age-related macular degeneration | |
| dc.subject.keyword | Cataract surgery | |
| dc.subject.keyword | Extended depth of focus IOL | |
| dc.subject.keyword | Non-diffractive IOL | |
| dc.subject.keyword | Patient-reported outcomes | |
| dc.subject.keyword | Visual acuity | |
| dc.subject.ucm | Ciencias Biomédicas | |
| dc.subject.unesco | 32 Ciencias Médicas | |
| dc.title | Visual Outcomes of a Non-Diffractive Extended Depth-of-Focus Intraocular Lens in Patients with Early-Stage Age-Related Macular Degeneration | |
| dc.type | journal article | |
| dc.type.hasVersion | VoR | |
| dc.volume.number | 14 | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 1bbcfafa-1b33-4213-9a8d-2a1c633e8e85 | |
| relation.isAuthorOfPublication | dd75532a-6964-4579-bbb1-671f827cc2d2 | |
| relation.isAuthorOfPublication | 3360352c-552e-4aab-aa7d-ec88baa8079e | |
| relation.isAuthorOfPublication.latestForDiscovery | 1bbcfafa-1b33-4213-9a8d-2a1c633e8e85 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Visual_Outcomes_of_a_Non_diffractive.pdf
- Size:
- 1.87 MB
- Format:
- Adobe Portable Document Format


