Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

New probe for the improvement of the Spatial Resolution in total-body PET (PROScRiPT)

dc.conference.date2021
dc.conference.placePraga
dc.conference.titleConference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA) (2021. Prague, Czech Republic)
dc.contributor.authorRos, A.
dc.contributor.authorBarrientos, L.
dc.contributor.authorBorja Lloret, M.
dc.contributor.authorCasaña, J. V.
dc.contributor.authorMuñoz, E.
dc.contributor.authorRoser, J.
dc.contributor.authorUdías Moinelo, José Manuel
dc.contributor.authorViegas, R.
dc.contributor.authorLlosá, G.
dc.date.accessioned2023-06-17T10:14:15Z
dc.date.available2023-06-17T10:14:15Z
dc.date.issued2021
dc.descriptionConference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA) (2021. Prague, Czech Republic). This work was supported by grant number SEJIGENT/2019/14.
dc.description.abstractIn recent decades, PET scanners have been widely used for diagnosis and treatment monitoring in nuclear medicine. The continuous effort of the scientific community has led to improvements in scanner performance. Total-body PET is one of the latest upgrades in PET scanners. These kinds of scanners are able to scan the whole body of the patient with a single bed position, since the scanner tube is long enough for the patient to fit inside. While these scanners show unprecedented efficiency and extended field-of-view, a drawback is their low spatial resolution compared to dedicated scanners. In order to improve the spatial resolution of specific areas when measuring with a total-body PET scanner, the IRIS group at IFIC-Valencia is developing a probe. The proposed setup of the probe contains a monolithic scintillation crystal and a SiPM. The signal of the probe is read out by a TOFPET2 ASIC from PETsys, which has shown good performance for PET in terms of spatial and time resolutions. Furthermore, the PETsys technology generates a trigger signal that will be used to time synchronise the probe and the scanner. The proof-of-concept of the probe will be tested in a Preclinical Super Argus PET/CT scanner for small animals located at IFIC. Preliminary simulations of the scanner and the probe under ideal conditions show a slight improvement in the position reconstruction compared to the data obtained with the scanner, therefore we expect a considerable improvement when using the probe in a total-body PET scanner. Characterisation tests of the probe have been performed with a Na-22 point-like source, obtaining an energy resolution of 9.09% for the 511 keV energy peak and a temporal resolution of 619 ps after time walk correction. The next step of the project is to test the probe measuring in temporal coincidence with the scanner.
dc.description.departmentDepto. de Estructura de la Materia, Física Térmica y Electrónica
dc.description.facultyFac. de Ciencias Físicas
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/73443
dc.identifier.doi10.1051/epjconf/202125309004
dc.identifier.issn2100-014X
dc.identifier.officialurlhttps://doi.org/10.1051/epjconf/202125309004
dc.identifier.relatedurlhttps://www.epj-conferences.org/
dc.identifier.urihttps://hdl.handle.net/20.500.14352/8941
dc.journal.titleEPJ Web of Conferences
dc.language.isoeng
dc.publisherE D P Sciences
dc.relation.projectIDSEJIGENT/2019/14
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.cdu539.1
dc.subject.keywordInsert
dc.subject.ucmFísica nuclear
dc.subject.unesco2207 Física Atómica y Nuclear
dc.titleNew probe for the improvement of the Spatial Resolution in total-body PET (PROScRiPT)
dc.typeconference paper
dc.volume.number253
dspace.entity.typePublication
relation.isAuthorOfPublication3dc23e23-6e7e-47dd-bd61-8b6b7a1ad75f
relation.isAuthorOfPublication.latestForDiscovery3dc23e23-6e7e-47dd-bd61-8b6b7a1ad75f

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
UdíasJM46libre+CC BY.pdf
Size:
4.65 MB
Format:
Adobe Portable Document Format