Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Intensity-based axial localization at the quantum limit

dc.contributor.authorŘeháček, J.
dc.contributor.authorStoklasa, Bohumil
dc.contributor.authorKoutný, Dominik
dc.contributor.authorHradil, Zdenek
dc.contributor.authorSánchez Soto, Luis Lorenzo
dc.date.accessioned2023-06-16T15:15:43Z
dc.date.available2023-06-16T15:15:43Z
dc.date.issued2019-11-07
dc.description© 2019 American Physical Society. We thank Robert W. Boyd for helpful discussions. We acknowledge financial support from the Czech Science Foundation (Grant No. 18-04291S), the Technology Agency of the Czech Republic (Grant No. TE01020229), the Palacky University (Grant No. IGA_PrF_2019_007), and the Spanish MINECO (Grants No. FIS2015-67963-P and No. PGC2018-099183-B-I00).
dc.description.abstractWe derive fundamental precision bounds for single-point axial localization. For Gaussian beams, this ultimate limit can be achieved with a single intensity scan, provided the camera is placed at one of two optimal transverse detection planes. Hence, for axial localization there is no need of more complicated detection schemes. The theory is verified with an experimental demonstration of axial resolution 3 orders of magnitude below the classical depth of focus.
dc.description.departmentDepto. de Óptica
dc.description.facultyFac. de Ciencias Físicas
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad (MINECO)
dc.description.sponsorshipCzech Science Foundation
dc.description.sponsorshipTechnology Agency of the Czech Republic
dc.description.sponsorshipPalacky University
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/58700
dc.identifier.doi10.1103/PhysRevLett.123.193601
dc.identifier.issn0031-9007
dc.identifier.officialurlhttp://dx.doi.org/10.1103/PhysRevLett.123.193601
dc.identifier.relatedurlhttps://journals.aps.org
dc.identifier.urihttps://hdl.handle.net/20.500.14352/6020
dc.issue.number19
dc.journal.titlePhysical review letters
dc.language.isoeng
dc.publisherThe American Physical Society
dc.relation.projectID(FIS2015-67963-P ; PGC2018-099183-B-I00)
dc.relation.projectID18-04291S
dc.relation.projectIDTE01020229
dc.relation.projectIDIGA_PrF_2019_007
dc.rights.accessRightsopen access
dc.subject.cdu535
dc.subject.keywordFluorescence microscopy
dc.subject.ucmÓptica (Física)
dc.subject.unesco2209.19 Óptica Física
dc.titleIntensity-based axial localization at the quantum limit
dc.typejournal article
dc.volume.number123
dspace.entity.typePublication
relation.isAuthorOfPublication88b797ff-cbd7-4498-a9c7-4e39f4fa4776
relation.isAuthorOfPublication.latestForDiscovery88b797ff-cbd7-4498-a9c7-4e39f4fa4776

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
SanchezSotoLL 27 LIBRE.pdf
Size:
657.94 KB
Format:
Adobe Portable Document Format

Collections