Effect of Mesopic/Scotopic Luminance on Pupil Diameter and Anisocoria in Drivers Over 65 Years of Age

dc.conference.date1-5 mayo, 2005
dc.conference.placeFort Lauderdale, Florida, Estados Unidos.
dc.conference.titleAssociation for reseach in vision and ophthalmology (ARVO) 2005 Annual Meeting.
dc.contributor.authorPérez Carrasco, María Jesús
dc.contributor.authorSánchez Ramos, Celia
dc.contributor.authorMoral Martínez, M.I.
dc.contributor.authorPuell Marín, María Cinta
dc.contributor.authorLanga Moraga, Antonio
dc.date.accessioned2024-07-19T12:13:46Z
dc.date.available2024-07-19T12:13:46Z
dc.date.issued2005-05-05
dc.descriptionContiene resumen.
dc.description.abstractPurpose: To evaluate the changes produced in pupil diameter and anisocoria in mesopic and scotopic conditions in subjects over the age of 65 years. Methods: A prospective evaluation was performed of pupil diameter in 45 motor car drivers aged 65 to 80 years (69±6 years). Measurements were made using an infrared, binocular pupillometer P2000 (Procyon Instruments Ltd) at 3 luminance levels: 0.04 lux (scotopic), 0.4 lux (low mesopic) and 4 lux (high mesopic). For each measurement, 10 photographs of both eyes are automatically taken by the instrument. Results: In scotopic conditions, mean pupil sizes were RE 5.37±1.1 mm, LE 5.29±1 mm. When the luminance level was increased to 0.4 lux (low mesopic conditions) mioses of 18% and 17%, respectively for the right and left eyes, were observed, resulting in pupil diameters of RE 4.55±0.83 mm, LE 4.51±0.78 mm. In high mesopic conditions (4 lux), pupil diameters were RE 3.47±0.60 mm, LE 3.41±0.89 mm, corresponding to mioses from the previous luminance level of 28% and 29%, respectively. The diferences in pupil diameter among the three luminance levels were significant. No diferences attributable to the luminance level were detected between each eye. The degrees of anisocoria observed were 5.77%, 5.78% and 5.77% in scotopic, low and high mesopic conditions, respectively. No significant diferences in scotopic/mesopic pupil sizes were revealed when the population was divided into three (15–year) age groups, or according to sex. Conclusions: At scotopic and mesopic luminance levels, drivers over 65 years show significant diferences in pupil diameter but no changes in anisocoria.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/106922
dc.language.isoeng
dc.rights.accessRightsmetadata only access
dc.subject.keywordPupil
dc.subject.keywordAging
dc.subject.keywordClinical (human) or epidemiologic studies
dc.subject.keywordSystems/equipment/techniques
dc.subject.ucmÓptica y optometría
dc.subject.unesco2209 Óptica
dc.subject.unesco2209.15 Optometría
dc.titleEffect of Mesopic/Scotopic Luminance on Pupil Diameter and Anisocoria in Drivers Over 65 Years of Age
dc.title.alternativeEfecto de la luminancia mesópica/escotópica sobre el diámetro pupilar y la anisocoria en conductores mayores de 65 años
dc.typeconference poster
dc.type.hasVersionVoR
dspace.entity.typePublication
relation.isAuthorOfPublication7791e9b0-678d-49da-9010-8f913d903d58
relation.isAuthorOfPublication3360352c-552e-4aab-aa7d-ec88baa8079e
relation.isAuthorOfPublication720db6ca-117d-4df6-9208-aa25c7832cdf
relation.isAuthorOfPublication7ab030d7-bbaa-45e4-b265-110ccb4de4b0
relation.isAuthorOfPublication.latestForDiscovery7791e9b0-678d-49da-9010-8f913d903d58
Download
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Effect_of_Mesopic_Scotopic_Luminance.pdf
Size:
44.13 KB
Format:
Adobe Portable Document Format