Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Long-Term Follow-Up of Intrastromal Corneal Ring Segments in Paracentral Keratoconus with Coincident Corneal Keratometric, Comatic, and Refractive Axes: Stability of the Procedure

Loading...
Thumbnail Image

Full text at PDC

Publication date

2017

Advisors (or tutors)

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

HINDAWI PUBLISHING CORPORATION
Citations
Google Scholar

Citation

Abstract

Purpose: To assess the long-term outcomes of implanting intrastromal corneal ring segments (ICRSs) to correct central keratoconus with a high corneal asphericity value. Methods: Forty-three eyes with central keratoconus with a corneal asphericity value ≥-1.00 were evaluated before and after implanting an inferior 210-degree arc-length Ferrara-type AFR5 ICRS (AJL Ophthalmic, Spain). Logarithm of the minimum angle of resolution uncorrected (UDVA) and best-corrected (CDVA) distance visual acuity, corneal asphericity, root mean square for coma-like aberrations [computed for the Zernike terms Z (3, 1) and Z (3, -1)], and residual refractive errors analyzed using vector analysis were recorded before and at all follow-up visits. The postoperative follow-up duration was 3 years in all cases. Result: Mean UDVA (logarithm of the minimum angle of resolution scale) rose from 1.18 ± 0.59 to a postoperative 0.53 ± 0.39 after ICRS implantation (P < 0.0001). Mean CDVA varied in turn from 0.36 ± 0.18 to 0.17 ± 0.10 (P < 0.0001). CDVA remained unchanged or improved in all eyes after surgery. Both UDVA and CDVA were stable over the postoperative period (P > 0.05). The spherical equivalent declined steeply after ICRS implantation (P < 0.0001). Both spherical equivalent and refractive cylinder were stable over the postoperative period. The corneal asphericity and root mean square values for coma-like aberrations exhibited statistically significant decreases 6 months after ICRS implantation (P < 0.0001) and were also stable over postoperative follow-up (P > 0.05). Conclusions: These results suggest that implanting a single, inferior, 210-degree arc-length Ferrara-type ICRS is a safe, effective, and stable procedure for treating patients with central hyperprolate keratoconus.

Research Projects

Organizational Units

Journal Issue

Description

Received 20 December 2016; Revised 3 April 2017; Accepted 27 July 2017; Published 29 August 2017

Keywords

Collections