Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

´Impact of the superimposition methods on accuracy analyses in complete arch digital implant investigation.´

dc.contributor.authorLimones Burgos, Alvaro
dc.contributor.authorCascos Sanchez, Rocio
dc.contributor.authorMolinero Mourelle, Pedro
dc.contributor.authorMartínez Vázquez De Parga, Juan Antonio
dc.contributor.authorCelemín Viñuela, María Del Pilar Alicia
dc.contributor.authorGómez Polo, Miguel Ángel
dc.contributor.authorAbou-Ayash, Samir
dc.date.accessioned2025-01-16T08:39:31Z
dc.date.available2025-01-16T08:39:31Z
dc.date.issued2024
dc.description.abstractObjectives: To measure the impact of the superimposition methods on accuracy analyses in digital implant research using an ISO-recommended 3-dimensional (3D) metrology-grade inspection software. Materials and methods: A six-implant edentulous maxillary model was scanned using a desktop scanner (7Series; DentalWings; Montreal, Canada) and an intraoral scanner (TRIOS 4; 3Shape; Copenhagen, Denmark) to generate a reference and an experimental mesh, respectively. Thirty experimental standard tesselletion language (STL) files were superimposed onto the reference model’s STL using the core features of six superimposition methods, creating the following groups: initial automated pre-alignment (GI), landmark-based alignment (G1), partial area-based alignment (G2), entire area-based alignment (G3), and double alignment combining landmark-based alignment with entire model area-based alignment (G4 ) or the scan bodies’ surface (G5). The groups underwent various alignment variations, resulting in sixteen subgroups (n = 30). The alignment accuracy between experimental and reference meshes was quantified by using the root mean square (RMS) error as trueness and its fluctuation as precision. The Kruskal-Wallis test with a subsequent adjusted post-hoc Dunn’s pairwise comparison test was used to analyze the data (α = 0.05). The reliability of the measurements was assessed using the intraclass correlation coefficient (ICC). Results: A total of 480 superimpositions were performed. No significant differences were found in trueness and precision among the groups (p > 0.05), except for partial area-based alignment (p < 0.001). Subgroup analysis showed significant differences for partial area-based alignment considering only one scan body (p < 0.001). Initial automated alignment was as accurate as landmark-based, partial, or entire area-based alignments (p > 0.05). Double alignments did not improve alignment accuracy (p > 0.05). The entire area-based alignment of the scan bodies’ surface had the least effect on accuracy analyses. Conclusions: Digital oral implant investigation remains unaffected by the superimposition method when ISOrecommended 3D metrology-grade inspection software is used. At least two scan bodies are needed when considering partial area-based alignments. Clinical significance: The superimposition method choice within the tested ISO-recommended 3D inspection software did not impact accuracy analyses in digital implant investigation.
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citation´Limones- Burgos A.Molinero-Mourelle P. Delgado S. Martinez-Vazquez de Parga JA.Celemin-Viñuela A.Impact of the superimposition methods and the designated comparison area on accuracy analyses in dentate models.Journal of Dentistry.2024
dc.identifier.doi10.1016/j.jdent.2024.105081
dc.identifier.essn1879-176X
dc.identifier.issn'0300-5712'
dc.identifier.officialurlhttps://www.sciencedirect.com/journal/journal-of-dentistry
dc.identifier.pmid38797486
dc.identifier.urihttps://hdl.handle.net/20.500.14352/114598
dc.issue.number105081
dc.journal.title'Journal of Dentistry'.
dc.language.isoeng
dc.publisher'Elsevier'
dc.rights.accessRightsopen access
dc.subject.cdu616.314-089.843
dc.subject.keywordEscaner intraoral
dc.subject.keywordOdontología digital
dc.subject.keywordImplantes dentales´
dc.subject.ucmOdontología (Odontología)
dc.subject.ucmImplantes dentales
dc.subject.unesco3299 Otras Especialidades Médicas
dc.title´Impact of the superimposition methods on accuracy analyses in complete arch digital implant investigation.´
dc.typejournal article
dc.type.hasVersionAM
dc.volume.number147
dspace.entity.typePublication
relation.isAuthorOfPublication3ba6a7c0-7a62-4bb8-bd9f-c860ac81443a
relation.isAuthorOfPublication679037d0-9151-469f-b376-82e430ee7e1d
relation.isAuthorOfPublication9700c70b-34f2-4d6a-8e12-92587c9186fb
relation.isAuthorOfPublication.latestForDiscovery3ba6a7c0-7a62-4bb8-bd9f-c860ac81443a

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Impact of the superimposition methods on accuracy analyses in complete arch.pdf
Size:
7.16 MB
Format:
Adobe Portable Document Format

Collections