Validation of the use of a smart band in recording spatiotemporal gait parameters in the 6-minute walk test

dc.contributor.authorOrtiz Gutiérrez, Rosa
dc.contributor.authorLópez Marcos, José Javier
dc.contributor.authorMaté Muñoz, José Luis
dc.contributor.authorMoreta De Esteban, Paloma
dc.contributor.authorMartín Casas, Patricia
dc.date.accessioned2025-10-08T18:13:48Z
dc.date.available2025-10-08T18:13:48Z
dc.date.issued2025-04-21
dc.descriptionThis article belongs to the Special Issue Sensors and Artificial Intelligence for Analyzing Human Behavior in Sports and Physical Activity
dc.description.abstractWearable monitoring devices, such as smart bands, have emerged as accessible and non-invasive tools for assessing physiological and spatiotemporal gait parameters in various clinical tests. This study aimed to validate the use of the Xiaomi Mi Band 6 for recording gait parameters during the six-minute walk test (6MWT). Seventy participants without gait impairments were recruited, and the measurements obtained with the smart band were compared to reference methods (evaluator, pedometer, and pulse oximeter). The physiological parameter results showed that the smart band demonstrated good accuracy in heart rate monitoring but lower agreement in oxygen saturation measurements. Gait parameters indicated excellent agreement in step count (ICC > 0.9) and step frequency (ICC > 0.75), whereas step length and distance estimations showed higher variability. These findings suggest that the Xiaomi Mi Band 6 is a viable alternative for measuring specific gait parameters, though with limitations in certain aspects of accuracy.
dc.description.departmentDepto. de Fisioterapia
dc.description.facultyFac. de Enfermería, Fisioterapia y Podología
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationOrtiz-Gutiérrez, R.M.; López-Marcos, J.J.; Maté-Muñoz, J.L.; Moreta-de-Esteban, P.; Martín-Casas, P. Validation of the Use of a Smart Band in Recording Spatiotemporal Gait Parameters in the 6-Minute Walk Test. Sensors 2025, 25, 2621. https://doi.org/10.3390/s25082621
dc.identifier.doi10.3390/s25082621
dc.identifier.officialurlhttps://doi.org/10.3390/s25082621
dc.identifier.relatedurlhttps://www.mdpi.com/1424-8220/25/8/2621
dc.identifier.urihttps://hdl.handle.net/20.500.14352/124687
dc.issue.number8
dc.journal.titleSensors
dc.language.isoeng
dc.page.final15
dc.page.initial1
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.rightsAttribution 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.cdu615.8
dc.subject.keywordgait analysis
dc.subject.keywordwearable electronic devices
dc.subject.keyworddigital health
dc.subject.keywordvalidation study
dc.subject.ucmCiencias Biomédicas
dc.subject.unesco3299 Otras Especialidades Médicas
dc.titleValidation of the use of a smart band in recording spatiotemporal gait parameters in the 6-minute walk test
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number25
dspace.entity.typePublication
relation.isAuthorOfPublication254c9b60-c456-45d8-86a1-f16e2e375b12
relation.isAuthorOfPublication66b405c9-4ec9-4d29-96d3-7d62a046cbdc
relation.isAuthorOfPublication940310d8-32ac-4af2-b6ee-a7c9eb72a6c0
relation.isAuthorOfPublication56e03ac7-ee70-40c5-88ed-daa491e647d9
relation.isAuthorOfPublicationaffec10d-497c-4aae-8366-5f86b383b8c5
relation.isAuthorOfPublication.latestForDiscovery254c9b60-c456-45d8-86a1-f16e2e375b12

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Validation_of_the_Use_Smart.pdf
Size:
1.23 MB
Format:
Adobe Portable Document Format

Collections