Intraocular pressure and biomechanical corneal properties measure by ocular response analyser in patients with primary congenital glaucoma

dc.contributor.authorPerucho González, Lucía
dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.contributor.authorMorales Fernández, Laura
dc.contributor.authorBañeros Rojas, Paula
dc.contributor.authorSáenz Francés, Federico
dc.contributor.authorGarcía Feijoo, Julián
dc.dateReceived on July 9th, 2015. Accepted on September 23rd, 2015.
dc.date.accessioned2023-06-17T21:55:28Z
dc.date.available2023-06-17T21:55:28Z
dc.date.issued2016-08
dc.description.abstractPurpose: To measure the differences in corneal hysteresis (CH) and corneal resistance factor (CRF) in primary congenital glaucoma (PCG) and in control subjects using ocular response analyser (ORA) and also to compare intraocular pressure (IOP) measurements given by ORA against IOP given by Perkins tonometer, a handheld version of Goldman applanation tonometer (GAT), to determine correlation. Methods: One hundred and eighteen eyes of 78 patients with PCG (group I) and 103 eyes of 53 controls (group II) were evaluated using ORA. In all participants, IOP was measured using the Perkins tonometer. The ORA device uses applanation pressure peaks to generate the corneal-compensated IOP (IOPcc), which is reportedly independent of corneal thickness, and the measurement of Goldman-correlated IOP (IOPg), which is influenced by corneal thickness. Results The measures in group I were as follows: IOPcc 20.92 ± 5.33; IOPg 18.87 ± 6.67; CH 8.51 ± 2.25; CRF 9.85 ± 3.03; and IOP measured by Goldman 18.32 ± 5.13. The measures in group II were as follows: IOPcc 14.33 ± 2.91; IOPg 14.77 ± 3.00; CH 11.37 ± 1.61; CRF 11.02 ± 1.74; and IOP measured by Goldman 13.74 ± 2.42. The differences of all parameters compared between both groups were statistically significant (p < 0.001 for CH and for all IOP measures and p = 0.001 for CRF). The values of IOPcc, IOPg and IOP measured with Goldman were higher in group I than the values in group II. However, CH and CRF values were lower in group I. Conclusion: A decrease in CH and CRF has been observed in patients with PCG compared to controls. Future research should assess how these parameters are modified in PCG and whether they could provide more information about progression.en
dc.description.departmentUnidad Docente de Inmunología, Oftalmología y ORL
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/42614
dc.identifier.citationPerucho González, L., Martínez De La Casa Fernández-Borrella, J. M., Morales fernández, L. et al. «Intraocular Pressure and Biomechanical Corneal Properties Measure by Ocular Response Analyser in Patients with Primary Congenital Glaucoma». Acta Ophthalmologica, vol. 94, n.o 5, agosto de 2016. DOI.org (Crossref), https://doi.org/10.1111/aos.12912.
dc.identifier.doi10.1111/aos.12912
dc.identifier.issn1755-375X
dc.identifier.officialurlhttp://dx.doi.org/10.1111/aos.12912
dc.identifier.relatedurlhttp://onlinelibrary.wiley.com/doi/10.1111/aos.12912/abstract
dc.identifier.relatedurlhttps://www.ncbi.nlm.nih.gov/pubmed/26647905
dc.identifier.urihttps://hdl.handle.net/20.500.14352/17794
dc.issue.number5
dc.journal.titleActa Ophthalmologica
dc.language.isoeng
dc.page.final297
dc.page.initial293
dc.publisherJohn Wiley & Sons Ltd.
dc.rights.accessRightsrestricted access
dc.subject.cdu612.842.6
dc.subject.cdu617.713
dc.subject.cdu617.7-007.681
dc.subject.keywordPrimary congenital glaucoma
dc.subject.keywordCorneal resistance factor
dc.subject.keywordCorneal hysteresis
dc.subject.keywordOcular response analyser
dc.subject.keywordCorneal biomechanics
dc.subject.ucmOftalmología
dc.subject.unesco3201.09 Oftalmología
dc.titleIntraocular pressure and biomechanical corneal properties measure by ocular response analyser in patients with primary congenital glaucomaen
dc.typejournal article
dc.volume.number94
dspace.entity.typePublication
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication558b8023-6d72-4dff-9f99-2e60f6f31843
relation.isAuthorOfPublication.latestForDiscovery558b8023-6d72-4dff-9f99-2e60f6f31843

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
intraocular pressure-ActOPHT-2016.pdf
Size:
313.94 KB
Format:
Adobe Portable Document Format

Collections