The Chester Step Test Is a Reproducible Tool to Assess Exercise Capacity and Exertional Desaturation in Post-COVID-19 Patients
Loading...
Official URL
Full text at PDC
Publication date
2022
Advisors (or tutors)
Editors
Journal Title
Journal ISSN
Volume Title
Publisher
MDPI
Citation
Abstract
Many people recovering from an acute episode of coronavirus disease (COVID-19) experience prolonged symptoms. Exercise testing is a feasible and cost-effective option for assessing exercise tolerance, fatigue, and dyspnea related to effort. Being that the Chester step test (CST) is a progressive, submaximal test for predicting aerobic capacity, it could be a good option to explore. This study aimed to determine the reproducibility of CST for assessing exertional desaturation and exercise capacity in patients post-COVID-19 disease. A cross-sectional study was conducted on postCOVID-19 patients. Two attempts of the CST were performed. The intraclass correlation coefficient (ICC) was used to assess agreement between the two tests. Forty-two symptomatic post-COVID-19 patients were included, the mean age was 53.8 ± 10.3 years, and 52% were female. There was no significant difference between both tests (p = 0.896). Twenty-four percent of participants (10 cases) had a clinically significant decrease in SpO2 at the first assessment, compared to 30.1% (13 cases) at the second, with no significant difference. An ICC of 0.993 (95% CI: 0.987 to 0.996) was obtained for the total number of steps in the CST