Accuracy of the Justy II apex locator in determining working length in simulated horizontal and vertical fractures
dc.contributor.author | Azabal Arroyo, Magdalena | |
dc.contributor.author | Garcia Otero, D | |
dc.contributor.author | Macorra García, José Carlos De La | |
dc.date.accessioned | 2023-06-20T12:41:38Z | |
dc.date.available | 2023-06-20T12:41:38Z | |
dc.date.issued | 2004 | |
dc.description.abstract | Aim: to study the effectiveness of an electronic apex locator (Justy II) in locating simulated horizontal and vertical fractures in single roots. Methods: an electronic apex locator (EAL) (Justy II, Yoshida Dentcraft, Tokyo, Japan) was used to measure the distance within the canal of horizontal (n=31) and vertical (n=31) fractures, created with a disk in single-rooted teeth. Accuracy of the EAL was evaluated by comparing the measurements with those made using a size 10 file. Data were analyzed with the non-parametric Passing and Bablok method. Results: for simulated horizontal fractures the EAL measured exactly the same length as a size 10 file, without constant or proportional errors. In vertical simulated fractures the EAL measured (on average) with a constant error of 7.5 mm shorter than the size 10 file; the difference had a wide confidence interval (–72.3 to 2.6 mm). Conclusion: in this laboratory study, the Justy II EAL was able to determine accurately the position of simulated horizontal fractures but was unreliable when measuring simulated vertical fractures. | |
dc.description.department | Depto. de Odontología Conservadora y Prótesis | |
dc.description.faculty | Fac. de Odontología | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/4927 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/52242 | |
dc.journal.title | International Endodontic Journal | |
dc.language.iso | spa | |
dc.page.final | 177 | |
dc.page.initial | 174 | |
dc.rights.accessRights | open access | |
dc.subject.keyword | Localizador electrónico de ápices | |
dc.subject.keyword | Fractura radicular horizontal | |
dc.subject.keyword | Fractura radicular vertical | |
dc.subject.keyword | Endodoncia | |
dc.subject.ucm | Endodoncia | |
dc.subject.unesco | 3213.13 Ortodoncia-Estomatología | |
dc.title | Accuracy of the Justy II apex locator in determining working length in simulated horizontal and vertical fractures | |
dc.type | journal article | |
dc.volume.number | 37 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 0b38ba8d-c9aa-404d-8ec6-b8c2d6a78884 | |
relation.isAuthorOfPublication.latestForDiscovery | 0b38ba8d-c9aa-404d-8ec6-b8c2d6a78884 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Accuracy_of_the_Justy_II_apex.pdf
- Size:
- 117.94 KB
- Format: