Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Accuracy of the Justy II apex locator in determining working length in simulated horizontal and vertical fractures

dc.contributor.authorAzabal Arroyo, Magdalena
dc.contributor.authorGarcia Otero, D
dc.contributor.authorMacorra García, José Carlos De La
dc.date.accessioned2023-06-20T12:41:38Z
dc.date.available2023-06-20T12:41:38Z
dc.date.issued2004
dc.description.abstractAim: to study the effectiveness of an electronic apex locator (Justy II) in locating simulated horizontal and vertical fractures in single roots. Methods: an electronic apex locator (EAL) (Justy II, Yoshida Dentcraft, Tokyo, Japan) was used to measure the distance within the canal of horizontal (n=31) and vertical (n=31) fractures, created with a disk in single-rooted teeth. Accuracy of the EAL was evaluated by comparing the measurements with those made using a size 10 file. Data were analyzed with the non-parametric Passing and Bablok method. Results: for simulated horizontal fractures the EAL measured exactly the same length as a size 10 file, without constant or proportional errors. In vertical simulated fractures the EAL measured (on average) with a constant error of 7.5 mm shorter than the size 10 file; the difference had a wide confidence interval (–72.3 to 2.6 mm). Conclusion: in this laboratory study, the Justy II EAL was able to determine accurately the position of simulated horizontal fractures but was unreliable when measuring simulated vertical fractures.
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/4927
dc.identifier.urihttps://hdl.handle.net/20.500.14352/52242
dc.journal.titleInternational Endodontic Journal
dc.language.isospa
dc.page.final177
dc.page.initial174
dc.rights.accessRightsopen access
dc.subject.keywordLocalizador electrónico de ápices
dc.subject.keywordFractura radicular horizontal
dc.subject.keywordFractura radicular vertical
dc.subject.keywordEndodoncia
dc.subject.ucmEndodoncia
dc.subject.unesco3213.13 Ortodoncia-Estomatología
dc.titleAccuracy of the Justy II apex locator in determining working length in simulated horizontal and vertical fractures
dc.typejournal article
dc.volume.number37
dspace.entity.typePublication
relation.isAuthorOfPublication0b38ba8d-c9aa-404d-8ec6-b8c2d6a78884
relation.isAuthorOfPublication.latestForDiscovery0b38ba8d-c9aa-404d-8ec6-b8c2d6a78884

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Accuracy_of_the_Justy_II_apex.pdf
Size:
117.94 KB
Format:
Adobe Portable Document Format

Collections