An Electrochemical Enzyme Biosensor for 3-Hydroxybutyrate Detection Using Screen-Printed Electrodes Modified by Reduced Graphene Oxide and Thionine
dc.contributor.author | Martínez García, Gonzalo | |
dc.contributor.author | Pérez Julián, Elena | |
dc.contributor.author | Agüí Chicharro, María Lourdes | |
dc.contributor.author | Cabré, Naomí | |
dc.contributor.author | Joven, Jorge | |
dc.contributor.author | Yáñez-Sedeño Orive, Paloma | |
dc.contributor.author | Pingarrón Carrazón, José Manuel | |
dc.date.accessioned | 2023-06-18T00:02:03Z | |
dc.date.available | 2023-06-18T00:02:03Z | |
dc.date.issued | 2017-11-11 | |
dc.description.abstract | A biosensor for 3-hydroxybutyrate (3-HB) involving immobilization of the enzyme 3-hydroxybutyrate dehydrogenase onto a screen-printed carbon electrode modified with reduced graphene oxide (GO) and thionine (THI) is reported here. After addition of 3-hydroxybutyrate or the sample in the presence of NAD+ cofactor, the generated NADH could be detected amperometrically at 0.0 V vs. Ag pseudo reference electrode. Under the optimized experimental conditions, a calibration plot for 3-HB was constructed showing a wide linear range between 0.010 and 0.400 mM 3-HB which covers the clinically relevant levels for diluted serum samples. In addition, a limit of detection of 1.0 µM, much lower than that reported using other biosensors, was achieved. The analytical usefulness of the developed biosensor was demonstrated via application to spiked serum samples. | |
dc.description.department | Depto. de Química Analítica | |
dc.description.faculty | Fac. de Ciencias Químicas | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Ministerio de Economía y Competitividad (MINECO) | |
dc.description.sponsorship | Comunidad de Madrid | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/66142 | |
dc.identifier.doi | 10.3390/bios7040050 | |
dc.identifier.issn | 2079-6374 | |
dc.identifier.officialurl | https://doi.org/10.3390/bios7040050 | |
dc.identifier.relatedurl | https://www.mdpi.com/2079-6374/7/4/50 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/19175 | |
dc.issue.number | 4 | |
dc.journal.title | Biosensors | |
dc.language.iso | eng | |
dc.page.initial | 50 | |
dc.publisher | MDPI | |
dc.relation.projectID | CTQ2015-70023-R y CTQ2015-64402-C2-1-R | |
dc.relation.projectID | NANOAVANSENS-CM (S2013/MT3029) | |
dc.rights | Atribución 3.0 España | |
dc.rights.accessRights | open access | |
dc.rights.uri | https://creativecommons.org/licenses/by/3.0/es/ | |
dc.subject.keyword | 3-hydroxybutyrate | |
dc.subject.keyword | graphene | |
dc.subject.keyword | thionine | |
dc.subject.keyword | electrochemical biosensor | |
dc.subject.keyword | diabetic ketoacidosis | |
dc.subject.ucm | Bioquímica (Química) | |
dc.subject.ucm | Química analítica (Química) | |
dc.subject.unesco | 2301 Química Analítica | |
dc.title | An Electrochemical Enzyme Biosensor for 3-Hydroxybutyrate Detection Using Screen-Printed Electrodes Modified by Reduced Graphene Oxide and Thionine | |
dc.type | journal article | |
dc.volume.number | 7 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | ba1cfa29-0064-4c8d-9c24-b0093bfe6d0a | |
relation.isAuthorOfPublication | 06ab2fa0-2b2d-4b58-80ed-82f9cc767175 | |
relation.isAuthorOfPublication | 8808f99c-5f56-4562-839a-517626c76dad | |
relation.isAuthorOfPublication.latestForDiscovery | ba1cfa29-0064-4c8d-9c24-b0093bfe6d0a |
Download
Original bundle
1 - 1 of 1