Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Magnetic Bead-Based Electrochemical Immunoassays On-Drop and On-Chip for Procalcitonin Determination: Disposable Tools for Clinical Sepsis Diagnosis

dc.contributor.authorMolinero-Fernández, Águeda
dc.contributor.authorMoreno Guzmán, María
dc.contributor.authorLópez, Miguel Ángel
dc.contributor.authorEscarpa, Alberto
dc.date.accessioned2023-06-17T09:12:19Z
dc.date.available2023-06-17T09:12:19Z
dc.date.issued2020-06-17
dc.description.abstractProcalcitonin (PCT) is a known protein biomarker clinically used for the early stages of sepsis diagnosis and therapy guidance. For its reliable determination, sandwich format magnetic bead-based immunoassays with two different electrochemical detection approaches are described: (i) disposable screen-printed carbon electrodes (SPE-C, on-drop detection); (ii) electro-kinetically driven microfluidic chips with integrated Au electrodes (EMC-Au, on-chip detection). Both approaches exhibited enough sensitivity (limit of detection (LOD) of 0.1 and 0.04 ng mL−1 for SPE-C and EMC-Au, respectively; cutoff 0.5 ng mL−1), an adequate working range for the clinically relevant concentrations (0.5–1000 and 0.1–20 ng mL−1 for SPE-C and EMC-Au, respectively), and good precision (RSD < 9%), using low sample volumes (25 µL) with total assay times less than 20 min. The suitability of both approaches was successfully demonstrated by the analysis of human serum and plasma samples, for which good recoveries were obtained (89–120%). Furthermore, the EMC-Au approach enabled the easy automation of the process, constituting a reliable alternative diagnostic tool for on-site/bed-site clinical analysis.
dc.description.departmentDepto. de Química en Ciencias Farmacéuticas
dc.description.facultyFac. de Farmacia
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Economía y Competitividad (MINECO)
dc.description.sponsorshipComunidad de Madrid
dc.description.sponsorshipLa Caixa
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/67557
dc.identifier.doi10.3390/bios10060066
dc.identifier.issn2079-6374
dc.identifier.officialurlhttps://doi.org/10.3390/bios10060066
dc.identifier.relatedurlhttps://www.mdpi.com/2079-6374/10/6/66
dc.identifier.urihttps://hdl.handle.net/20.500.14352/8390
dc.issue.number6
dc.journal.titleBiosensors
dc.language.isoeng
dc.page.initial66
dc.publisherMDPI
dc.relation.projectID(CTQ2017-86441-C2-1-R)
dc.relation.projectIDTRANSNANOAVANSENS (S2018/NMT-4349)
dc.relation.projectIDLaCaixaImpulse program (CI017-00038)
dc.rightsAtribución 3.0 España
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/es/
dc.subject.keywordelectrochemical immunoassays
dc.subject.keywordmicrofluidic chips
dc.subject.keywordscreen-printed
dc.subject.keywordsepsis
dc.subject.ucmQuímica farmaceútica
dc.subject.ucmQuímica física (Farmacia)
dc.subject.unesco2390 Química Farmacéutica
dc.titleMagnetic Bead-Based Electrochemical Immunoassays On-Drop and On-Chip for Procalcitonin Determination: Disposable Tools for Clinical Sepsis Diagnosis
dc.typejournal article
dc.volume.number10
dspace.entity.typePublication
relation.isAuthorOfPublication96968530-a80d-4987-a341-f4a96697f66c
relation.isAuthorOfPublication.latestForDiscovery96968530-a80d-4987-a341-f4a96697f66c

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
biosensors-10-00066.pdf
Size:
1.27 MB
Format:
Adobe Portable Document Format

Collections