Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA Disculpen las molestias.
 

Calibration of Sensor Network for Outdoor Measurement of PM2.5 on High Wood-Heating Smoke in Temuco City

dc.contributor.advisorTrucillo, Paolo
dc.contributor.authorMuñoz Poblete, Carlos Omar
dc.contributor.authorHuircan Quilaqueo, Juan Ignacio
dc.contributor.authorJaramillo Montoya, Francisco
dc.contributor.authorBoso Gaspar, Àlex
dc.date.accessioned2024-04-25T17:16:34Z
dc.date.available2024-04-25T17:16:34Z
dc.date.issued2023-08-03
dc.description2023 Descuento MDPI
dc.description.abstractIn order to ascertain the spatial and temporal changes in the air quality in Temuco City, Chile, we created and installed a network of inexpensive sensors to detect PM2.5 particulate matter. The 21 measurement points deployed were based on a low-cost Sensiron SPS30 sensor, complemented with temperature and humidity sensors, an Esp32 microcontroller card with LoRa and WiFi wireless communication interface, and a solar charging unit. The units were calibrated using an airtight combustion chamber with a Grimm 11-E as a reference unit. The calibration procedure fits the parameters of a calibration model to map the raw low-cost particle-material measurements into reliable calibrated values. The measurements showed that the concentrations of fine particulate material recorded in Temuco present a high temporal and spatial variability. In critical contamination episodes, pollution reaches values as high as 354 µg/m3, and at the same time, it reaches 50 µg/m3 in other parts of the city. The contamination episodes show a similar trend around the city, and the peaks are in the time interval from 07:00 PM to 1:00 AM. In the winter, this time of day coincides with when families are usually home and there are low temperatures outside
dc.description.departmentDepto. de Física de Materiales
dc.description.facultyFac. de Ciencias Físicas
dc.description.fundingtypeDescuento UCM
dc.description.refereedTRUE
dc.description.sponsorshipFondo Nacional de Desarrollo Científico y Tecnológico(Chile)
dc.description.sponsorshipAgencia Nacional de Investigación y Desarrollo de Chile
dc.description.sponsorshipCenter of Interventional Medicine for Precision and Advanced Cellular Therapy
dc.description.statuspub
dc.identifier.citationMuñoz, C.; Huircan, J.; Jaramillo, F.; Boso, Á. Calibration of Sensor Network for Outdoor Measurement of PM2.5 on High Wood-Heating Smoke in Temuco City. Processes 2023, 11, 2338. https://doi.org/10.3390/ pr1108233
dc.identifier.doi10.3390/pr11082338
dc.identifier.essn2227-9717
dc.identifier.officialurlhttps://doi.org/10.3390/pr11082338
dc.identifier.urihttps://hdl.handle.net/20.500.14352/103535
dc.issue.number8
dc.journal.titleProcesses
dc.language.isoeng
dc.page.final2352
dc.page.initial2338
dc.publisherMDPI
dc.relation.projectIDinfo:eu-repo/grantAgreement/IDI18-0003
dc.relation.projectIDinfo:eu-repo/grantAgreement/FB210024
dc.rightsAttribution 4.0 International
dc.rights.accessRightsopen access
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject.cdu628.5
dc.subject.cdu504.3.054(83)"20"
dc.subject.keywordAir pollution
dc.subject.keywordLow-cost sensor
dc.subject.keywordParticle-matter calibration
dc.subject.keywordSpatial–temporal distribution
dc.subject.ucmNeumología
dc.subject.ucmFísica de materiales
dc.subject.unesco2208.06 detectores de Partículas
dc.subject.unesco3308.04 Ingeniería de la Contaminación
dc.subject.unesco2509.02 Contaminación Atmosférica
dc.titleCalibration of Sensor Network for Outdoor Measurement of PM2.5 on High Wood-Heating Smoke in Temuco City
dc.typejournal article
dc.type.hasVersionVOR
dc.volume.number11
dspace.entity.typePublication

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Processes_11.pdf
Size:
12.31 MB
Format:
Adobe Portable Document Format

Collections