Calibration of Sensor Network for Outdoor Measurement of PM2.5 on High Wood-Heating Smoke in Temuco City
dc.contributor.advisor | Trucillo, Paolo | |
dc.contributor.author | Muñoz Poblete, Carlos Omar | |
dc.contributor.author | Huircan Quilaqueo, Juan Ignacio | |
dc.contributor.author | Jaramillo Montoya, Francisco | |
dc.contributor.author | Boso Gaspar, Àlex | |
dc.date.accessioned | 2024-04-25T17:16:34Z | |
dc.date.available | 2024-04-25T17:16:34Z | |
dc.date.issued | 2023-08-03 | |
dc.description | 2023 Descuento MDPI | |
dc.description.abstract | In order to ascertain the spatial and temporal changes in the air quality in Temuco City, Chile, we created and installed a network of inexpensive sensors to detect PM2.5 particulate matter. The 21 measurement points deployed were based on a low-cost Sensiron SPS30 sensor, complemented with temperature and humidity sensors, an Esp32 microcontroller card with LoRa and WiFi wireless communication interface, and a solar charging unit. The units were calibrated using an airtight combustion chamber with a Grimm 11-E as a reference unit. The calibration procedure fits the parameters of a calibration model to map the raw low-cost particle-material measurements into reliable calibrated values. The measurements showed that the concentrations of fine particulate material recorded in Temuco present a high temporal and spatial variability. In critical contamination episodes, pollution reaches values as high as 354 µg/m3, and at the same time, it reaches 50 µg/m3 in other parts of the city. The contamination episodes show a similar trend around the city, and the peaks are in the time interval from 07:00 PM to 1:00 AM. In the winter, this time of day coincides with when families are usually home and there are low temperatures outside | |
dc.description.department | Depto. de Física de Materiales | |
dc.description.faculty | Fac. de Ciencias Físicas | |
dc.description.fundingtype | Descuento UCM | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Fondo Nacional de Desarrollo Científico y Tecnológico(Chile) | |
dc.description.sponsorship | Agencia Nacional de Investigación y Desarrollo de Chile | |
dc.description.sponsorship | Center of Interventional Medicine for Precision and Advanced Cellular Therapy | |
dc.description.status | pub | |
dc.identifier.citation | Muñoz, C.; Huircan, J.; Jaramillo, F.; Boso, Á. Calibration of Sensor Network for Outdoor Measurement of PM2.5 on High Wood-Heating Smoke in Temuco City. Processes 2023, 11, 2338. https://doi.org/10.3390/ pr1108233 | |
dc.identifier.doi | 10.3390/pr11082338 | |
dc.identifier.essn | 2227-9717 | |
dc.identifier.officialurl | https://doi.org/10.3390/pr11082338 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/103535 | |
dc.issue.number | 8 | |
dc.journal.title | Processes | |
dc.language.iso | eng | |
dc.page.final | 2352 | |
dc.page.initial | 2338 | |
dc.publisher | MDPI | |
dc.relation.projectID | info:eu-repo/grantAgreement/IDI18-0003 | |
dc.relation.projectID | info:eu-repo/grantAgreement/FB210024 | |
dc.rights | Attribution 4.0 International | |
dc.rights.accessRights | open access | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
dc.subject.cdu | 628.5 | |
dc.subject.cdu | 504.3.054(83)"20" | |
dc.subject.keyword | Air pollution | |
dc.subject.keyword | Low-cost sensor | |
dc.subject.keyword | Particle-matter calibration | |
dc.subject.keyword | Spatial–temporal distribution | |
dc.subject.ucm | Neumología | |
dc.subject.ucm | Física de materiales | |
dc.subject.unesco | 2208.06 detectores de Partículas | |
dc.subject.unesco | 3308.04 Ingeniería de la Contaminación | |
dc.subject.unesco | 2509.02 Contaminación Atmosférica | |
dc.title | Calibration of Sensor Network for Outdoor Measurement of PM2.5 on High Wood-Heating Smoke in Temuco City | |
dc.type | journal article | |
dc.type.hasVersion | VOR | |
dc.volume.number | 11 | |
dspace.entity.type | Publication |
Download
Original bundle