Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA Disculpen las molestias.
 

Deflectometric measurement of mechanical spectacle lens deformation

dc.contributor.authorPeral Cerda, María Asunción
dc.contributor.authorAlonso Fernández, José
dc.contributor.authorCanos Sanz, Joán
dc.contributor.authorBernabéu Martínez, Eusebio
dc.date.accessioned2023-06-20T19:05:33Z
dc.date.available2023-06-20T19:05:33Z
dc.date.copyright© The College of Optometrists.Published by Elsevier Science Ltd.
dc.date.issued2000-11
dc.descriptionWe thank T. Yonte for her teaching in the use of the moiré deflectometer. We also thank C. Illueca for his suggestions. This work has been supported by the project TAP98-070 1/97, from the Comisión Interministerial de Ciencia y Tecnología of Spain.
dc.description.abstractThe warpage of a set of six hard resin spherical lenses was measured when they were compressed by means of the tangential force exerted by a metal frame. The technique employed to measure the lenses improves over previous work both because greater precision is achieved, and because radii of curvature are measured in two perpendicular meridians. In this work, a representative sample of lenses has been used in order to test the way in which deformation depends on lens power and base. It is found that the induced warpage is enough to move the tested lenses between different base families, spoiling the initial design of the manufacturer.en
dc.description.departmentDepto. de Óptica
dc.description.facultyFac. de Ciencias Físicas
dc.description.refereedTRUE
dc.description.sponsorshipComisión Interministerial de Ciencia y Tecnología (España)
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/26799
dc.identifier.citationPeral Cerda, M. A., Alonso Fernández, J., Canos Sanz, J., Bernabéu Martínez, E. «Deflectometric Measurement of Mechanical Spectacle Lens Deformation». Ophthalmic and Physiological Optics, vol. 20, n.o 6, noviembre de 2000, pp. 473-79. DOI.org (Crossref), https://doi.org/10.1111/j.1475-1313.2000.tb01125.x.
dc.identifier.doi10.1111/j.1475-1313.2000.tb01125.x
dc.identifier.issn0275-5408
dc.identifier.officialurlhttp://dx.doi.org/10.1111/j.1475-1313.2000.tb01125.x
dc.identifier.relatedurlhttp://onlinelibrary.wiley.com
dc.identifier.urihttps://hdl.handle.net/20.500.14352/59234
dc.issue.number6
dc.journal.titleOphtalmic and Physiological Optics
dc.language.isoeng
dc.page.final479
dc.page.initial473
dc.publisherElsevier Science B. V.
dc.relation.projectIDTAP98- 070 1/97
dc.rights.accessRightsopen access
dc.subject.cdu535
dc.subject.keywordOphtalmology
dc.subject.ucmÓptica (Física)
dc.subject.unesco2209.19 Óptica Física
dc.titleDeflectometric measurement of mechanical spectacle lens deformationen
dc.typejournal article
dc.volume.number20
dspace.entity.typePublication
relation.isAuthorOfPublication2b3052fa-b98a-44f3-a982-f01bccb83c6a
relation.isAuthorOfPublicationf7b5b178-742c-418d-80d3-769a169f6dd9
relation.isAuthorOfPublication37745430-863e-41b2-94e9-eaffe06fdc53
relation.isAuthorOfPublication.latestForDiscoveryf7b5b178-742c-418d-80d3-769a169f6dd9

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Bernabeu,E83.pdf
Size:
706.75 KB
Format:
Adobe Portable Document Format

Collections