Para depositar en Docta Complutense, identifícate con tu correo @ucm.es en el SSO institucional. Haz clic en el desplegable de INICIO DE SESIÓN situado en la parte superior derecha de la pantalla. Introduce tu correo electrónico y tu contraseña de la UCM y haz clic en el botón MI CUENTA UCM, no autenticación con contraseña.

Real-time dose reconstruction in proton therapy from in-beam PET measurements

dc.contributor.authorValladolid Onecha, Víctor
dc.contributor.authorEspinosa Rodríguez, Andrea
dc.contributor.authorSoneira-Landín, C.
dc.contributor.authorArias Valcayo, Fernando
dc.contributor.authorGaitán-Dominguez, S.
dc.contributor.authorMartínez Nouvilas, Víctor
dc.contributor.authorGarcía Díez, Marcos
dc.contributor.authorIbáñez García, Paula Beatriz
dc.contributor.authorEspaña, S.
dc.contributor.authorSánchez Parcerisa, Daniel
dc.contributor.authorCerrón-Campoo, F.
dc.contributor.authorVera-Sánchez, J. A.
dc.contributor.authorMazal, A.
dc.contributor.authorUdías Moinelo, José Manuel
dc.contributor.authorFraile Prieto, Luis Mario
dc.date.accessioned2025-07-21T07:41:56Z
dc.date.available2025-07-21T07:41:56Z
dc.date.issued2025-03-21
dc.description"This work was funded by Comunidad de Madrid, Spain under Projects PRONTO-CM (B2017/BMD-3888) and ASAP-CM (S2022/BMD7434). We acknowledge support by UCM under project pFLASH (PR27/21-014); Spanish MCIN/AEI/10.13039/501100011033 under Grants RADFLAP (PID2021-124094OA-I00), FLASHonCHIP (PLEC2022-009256), PROTOTWIN (TED2021-130592B-I00), mPET (PID2021-126998OB-I00) and INVENTOR (PID2022-137114OA-I00); European Union as part of the European Innovation Council’s Pathfinder Open Programme: RETIMAGER, 101099096. The authors acknowledge the support from The Centro de protonterapia Quirónsalud, for the beam time, and its technical staff for their contribution to the operation of the accelerator. This contribution is for the Moncloa Campus of International Excellence, ”Nuclear Physics Group-UCM,” Ref. 910059. Part of the calculations for this work were performed on the ”Computing Cluster for Physical Techniques,” funded partially by UCM and partially by EU Regional Funds."
dc.description.abstractObjective. Clinical implementation of in-beam positron emission tomography (PET) monitoring in proton therapy (PT) requires the integration of an online fast and reliable dose calculation engine. This manuscript reports on the achievement of real-time reconstruction of 3D dose and activity maps with proton range verification from experimental in-beam PET measurements. Approach. Several cylindrical homogeneous PMMA phantoms were irradiated with a monoenergetic 70 MeV proton beam in a clinical facility. Additionally, PMMA range-shifting foils of varying thicknesses were placed at the proximal surface of the phantom to investigate range shift prediction capabilities. PET activity was measured using a state-of-the-art in-house developed six-module PET scanner equipped with online PET reconstruction capabilities. For real-time dose estimation, we integrated this system with an in-beam dose estimation algorithm, which combines a graphical processing unit-based 3D reconstruction algorithm with a dictionary-based software, capable of estimating deposited doses from the 3D PET activity images. The range shift prediction performance has been quantitatively studied in terms of the minimum dose to be delivered and the maximum acquisition time. Main results. With this framework, 3D dose maps were accurately reconstructed and displayed with a delay as short as one second. For a dose fraction of 8.4 Gy at the Bragg peak maximum, range shifts as small as 1 mm could be detected. The quantitative analysis shows that accumulating 20 s of statistics from the start of the irradiation, doses down to 1 Gy could be estimated online with total uncertainties smaller than 2 mm. Significance. The hardware and software combination employed in this work can deliver dose maps and accurately predict range shifts after short acquisition times and small doses, suggesting that real-time monitoring and dose reconstruction during PT are within reach. Future work will focus on testing the methodology in more complex clinical scenarios and on upgrading the PET prototype for increased sensitivity.
dc.description.departmentDepto. de Estructura de la Materia, Física Térmica y Electrónica
dc.description.facultyFac. de Ciencias Físicas
dc.description.refereedTRUE
dc.description.sponsorshipMinisterio de Ciencia, Innovación y Universidades (España)
dc.description.sponsorshipComunidad de Madrid
dc.description.sponsorshipEuropean Commission
dc.description.sponsorshipUniversidad Complutense de Madrid
dc.description.statuspub
dc.identifier.citationV V Onecha et al 2025 Phys. Med. Biol. 70 075008
dc.identifier.doi10.1088/1361-6560/adbfd9
dc.identifier.essn1361-6560
dc.identifier.issn0031-9155
dc.identifier.officialurlhttps://doi.org/10.1088/1361-6560/adbfd9
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0969806X25003962
dc.identifier.urihttps://hdl.handle.net/20.500.14352/122635
dc.journal.titlePhysics in Medicine & Biology
dc.language.isoeng
dc.page.final112904-8
dc.page.initial112904-1
dc.publisherElsevier
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2022-137114OA-I00/ES/EXPLORACION IN VIVO DE LA RESPUESTA TISULAR A LA RADIACION/
dc.relation.projectIDPR47/21 TAU
dc.rightsAttribution-NonCommercial 4.0 Internationalen
dc.rights.accessRightsopen access
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/
dc.subject.cdu539.1
dc.subject.cdu615.849.6
dc.subject.keywordproton therapy
dc.subject.keywordonline dose reconstruction
dc.subject.keywordonline range verification
dc.subject.keywordproton dose reconstruction
dc.subject.keywordonline activity reconstruction
dc.subject.keywordIDE-PET
dc.subject.ucmFísica nuclear
dc.subject.ucmDiagnóstico por imagen y medicina nuclear
dc.subject.unesco2207 Física Atómica y Nuclear
dc.subject.unesco3201.12 Radioterapia
dc.titleReal-time dose reconstruction in proton therapy from in-beam PET measurements
dc.typejournal article
dc.type.hasVersionVoR
dc.volume.number236
dspace.entity.typePublication
relation.isAuthorOfPublicationbc4c2922-3f49-4ac1-a2f1-ba6eb6acb851
relation.isAuthorOfPublicationa285b1be-6df7-49f3-b9ec-aa142fbd87d1
relation.isAuthorOfPublication804c568d-8b53-4973-88db-74e1c3be3c41
relation.isAuthorOfPublicationdb35264d-21e6-4e5c-97e8-b5d284478b02
relation.isAuthorOfPublication70e3fb27-2552-4b37-b626-d012e5d925cf
relation.isAuthorOfPublication3e87aa6b-a8b0-482e-99ba-f8afc04e5340
relation.isAuthorOfPublicationd228b73c-ba3b-487d-91bd-5f4e22cf9c00
relation.isAuthorOfPublication3dc23e23-6e7e-47dd-bd61-8b6b7a1ad75f
relation.isAuthorOfPublicationec83106c-33f4-426c-afd6-68c5d859f9d4
relation.isAuthorOfPublication.latestForDiscoverybc4c2922-3f49-4ac1-a2f1-ba6eb6acb851

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Real-time dose reconstruction in proton therapy.pdf
Size:
3.17 MB
Format:
Adobe Portable Document Format

Collections