Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up
dc.contributor.author | Carreras Díaz, Humberto | |
dc.contributor.author | Carreras-Díaz, Josefina | |
dc.contributor.author | Carreras-Díaz, María del Rosario | |
dc.contributor.author | Lorente Velázquez, Amalia | |
dc.date.accessioned | 2025-01-10T13:34:52Z | |
dc.date.available | 2025-01-10T13:34:52Z | |
dc.date.issued | 2024-07 | |
dc.description.abstract | Aim: To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port (V4c T-ICL) implantation over 1y of follow-up. Methods: A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively, 1 and 12mo postoperatively. Vector analysis was used for astigmatism changes. Coefficient of adjustment (CAdj) was calculated for corneal coupling analysis. Results: The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up (P=0.193). At the last visit, 84% of the eyes achieved a CDVA of 0.00 logMAR or better. Regarding spherical equivalent refraction (SEQ), 96% of eyes were ranges of ±1.00 D and 84% of them within ±0.50 D. Also, 94% of eyes had a remaining refractive cylinder within ±1.00 D and 78% of them within ±0.50 D. Both, SEQ and refractive cylinder, remain stable over the postoperative follow-up (P=1.000 and P=0.660, respectively). In terms of surgically induced astigmatism (SIA), no statistically significant differences were found over the follow-up (P=0.102) and under correction was found with a correction index lower than the unit at each visit. A keratometric astigmatism induced of 0.59±0.53 (vector mean: 0.26×73°) D was reached at the last visit. No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits (P=0.129 and P=0.097 at 1 and 12mo respectively). No clinical significance was found for CAdj on with-the-rule astigmatism. No postoperative complications resulting from the surgery were found. Conclusion: Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness, safety, and stability during 1y of follow-up. Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery. Corneal coupling analysis results in no unexpected spherical change. | |
dc.description.department | Depto. de Optometría y Visión | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.identifier.citation | Carreras-Díaz H, Reñones de Abajo J, Carreras-Díaz MDR, Lorente-Velázquez A. Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up. Int J Ophthalmol. 2024 Jul 18;17(7):1322-1330. doi: 10.18240/ijo.2024.07.18. PMID: 39026921; PMCID: PMC11246948. | |
dc.identifier.doi | 10.18240/ijo.2024.07.18. | |
dc.identifier.officialurl | https://doi.org/10.18240/ijo.2024.07.18. | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/113742 | |
dc.issue.number | 18 | |
dc.journal.title | International Journal of Ophthalmology | |
dc.language.iso | eng | |
dc.page.final | 1330 | |
dc.page.initial | 1322 | |
dc.publisher | PubMed | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 International | en |
dc.rights.accessRights | open access | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject.cdu | 617.7-089.243 | |
dc.subject.keyword | V4c Toric collamer lens | |
dc.subject.keyword | Corneal astigmatism | |
dc.subject.keyword | Corneal coupling | |
dc.subject.keyword | Surgically induced astigmatism | |
dc.subject.ucm | Ciencias Biomédicas | |
dc.subject.unesco | 32 Ciencias Médicas | |
dc.title | Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up | |
dc.type | journal article | |
dc.type.hasVersion | VoR | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | f7b511b2-3096-4762-909a-330bed4c0489 | |
relation.isAuthorOfPublication.latestForDiscovery | f7b511b2-3096-4762-909a-330bed4c0489 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Refractive_outcomes_after_V4c_Toric_collamer_lens.pdf
- Size:
- 2.28 MB
- Format:
- Adobe Portable Document Format