Side-to-side magnet anastomosis system duodeno-ileostomy with sleeve gastrectomy: early multi-center results
dc.contributor.author | Gagner, Michel | |
dc.contributor.author | Cadiere, Guy-Bernard | |
dc.contributor.author | Abuladze, David | |
dc.contributor.author | Krinke, Todd | |
dc.contributor.author | Buchwald, J. N. | |
dc.contributor.author | Van Sante, Nathalie | |
dc.contributor.author | Van Gossum, Marc | |
dc.contributor.author | Koiava, Levan | |
dc.contributor.author | Odovic, Maja | |
dc.contributor.author | Poras, Mathilde | |
dc.contributor.author | Almutlaq, Lamees | |
dc.contributor.author | Sánchez Pernaute, Andrés | |
dc.contributor.author | Dziakova, Jana | |
dc.contributor.author | Torres García, Antonio José | |
dc.date.accessioned | 2025-01-27T13:53:17Z | |
dc.date.available | 2025-01-27T13:53:17Z | |
dc.date.issued | 2023-05-22 | |
dc.description.abstract | Introduction Gastrointestinal anastomoses with classical sutures and/or metal staples have resulted in significant bleeding and leak rates. This multi-site study evaluated the feasibility, safety, and preliminary effectiveness of a novel linear magnetic compression anastomosis device, the Magnet System (MS), to form a side-to-side duodeno-ileostomy (DI) diversion for weight loss and type 2 diabetes (T2D) resolution. Methods In patients with class II and III obesity (body mass index [BMI, kg/m2] ≥ 35.0– ≤ 50.0 with/without T2D [HbA1C > 6.5%]), two linear MS magnets were delivered endoscopically to the duodenum and ileum with laparoscopic assistance and aligned, initiating DI; sleeve gastrectomy (SG) was added. There were no bowel incisions or retained sutures/staples. Fused magnets were expelled naturally. Adverse events (AEs) were graded by Clavien-Dindo Classification (CDC). Results Between November 22, 2021 and July 18, 2022, 24 patients (83.3% female, mean ± SEM weight 121.9 ± 3.3 kg, BMI 44.4 ± 0.8) in three centers underwent magnetic DI. Magnets were expelled at a median 48.5 days. Respective mean BMI, total weight loss, and excess weight loss at 6 months (n = 24): 32.0 ± 0.8, 28.1 ± 1.0%, and 66.2 ± 3.4%; at 12 months (n = 5), 29.3 ± 1.5, 34.0 ± 1.4%, and 80.2 ± 6.6%. Group mean respective mean HbA1C and glucose levels dropped to 1.1 ± 0.4% and 24.8 ± 6.6 mg/dL (6 months); 2.0 ± 1.1% and 53.8 ± 6.3 mg/dL (12 months). There were 0 device-related AEs, 3 procedure-related serious AEs. No anastomotic bleeding, leakage, stricture, or mortality. Conclusion In a multi-center study, side-to-side Magnet System duodeno-ileostomy with SG in adults with class III obesity appeared feasible, safe, and effective for weight loss and T2D resolution in the short term. | |
dc.description.department | Depto. de Cirugía | |
dc.description.faculty | Fac. de Medicina | |
dc.description.refereed | TRUE | |
dc.description.status | pub | |
dc.identifier.citation | Gagner M, Cadiere GB, Sanchez-Pernaute A, Abuladze D, Krinke T, Buchwald JN, Van Sante N, Van Gossum M, Dziakova J, Koiava L, Odovic M, Poras M, Almutlaq L, Torres AJ. Side-to-side magnet anastomosis system duodeno-ileostomy with sleeve gastrectomy: early multi-center results. Surg Endosc. 2023 Aug;37(8):6452-6463. doi: 10.1007/s00464-023-10134-6. Epub 2023 May 22. PMID: 37217682; PMCID: PMC10202352. | |
dc.identifier.doi | 10.1007/s00464-023-10134-6 | |
dc.identifier.essn | 1432-2218 | |
dc.identifier.issn | 0930-2794 | |
dc.identifier.officialurl | https://doi.org/10.1007/s00464-023-10134-6 | |
dc.identifier.relatedurl | https://link.springer.com/journal/464 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/116333 | |
dc.issue.number | 8 | |
dc.journal.title | Surgical Endoscopy | |
dc.language.iso | eng | |
dc.page.final | 6463 | |
dc.page.initial | 6452 | |
dc.publisher | Springer | |
dc.rights | Attribution 4.0 International | en |
dc.rights.accessRights | open access | |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | |
dc.subject.cdu | 617 | |
dc.subject.keyword | Duodeno-ileostomy | |
dc.subject.keyword | Magnet system | |
dc.subject.keyword | Magnetic compression anastomosis | |
dc.subject.keyword | Metabolic/bariatric surgery | |
dc.subject.keyword | Obesity; Sleeve gastrectomy | |
dc.subject.keyword | Type 2 diabetes | |
dc.subject.ucm | Ciencias Biomédicas | |
dc.subject.unesco | 32 Ciencias Médicas | |
dc.title | Side-to-side magnet anastomosis system duodeno-ileostomy with sleeve gastrectomy: early multi-center results | |
dc.type | journal article | |
dc.type.hasVersion | VoR | |
dc.volume.number | 37 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 64ea548c-394b-4f2a-aeaa-2341b7416dc1 | |
relation.isAuthorOfPublication | 67684aca-02f9-4640-8ffb-39721eed1e75 | |
relation.isAuthorOfPublication | 790390e8-2a0b-4dca-9996-3e85d11acad7 | |
relation.isAuthorOfPublication.latestForDiscovery | 64ea548c-394b-4f2a-aeaa-2341b7416dc1 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Side-to-side magnet anastomosis system duodeno-ileostomy with sleeve gastrectomy- early multi-center results.pdf
- Size:
- 1.1 MB
- Format:
- Adobe Portable Document Format