Absolute radiometric calibration of TESS-W and SQM night sky brightness sensors
dc.contributor.author | Bará, Salvador | |
dc.contributor.author | Tapia Ayuga, Carlos | |
dc.contributor.author | Zamorano Calvo, Jaime | |
dc.date.accessioned | 2023-06-17T13:23:49Z | |
dc.date.available | 2023-06-17T13:23:49Z | |
dc.date.issued | 2019-03-17 | |
dc.description | © 2019 by the authors. This work was partially supported by Xunta de Galicia/FEDER, grant ED431B 2017/64 (SB), and partly developed within the framework of the Spanish Network for Light Pollution Studies, REECL (AYA2015-71542-REDT). CET and JZ acknowledge funding by the Spanish MICINN AYA2016-75808-R, by the Madrid Regional Government through the TEC2SPACE-CM Project (P2018/NMT-4291), and by STARS4ALL, a project funded by the European Union H2020-ICT-2015-688135. | |
dc.description.abstract | We develop a general optical model and describe the absolute radiometric calibration of the readings provided by two widely-used night sky brightness sensors based on irradiance-to-frequency conversion. The calibration involves the precise determination of the overall spectral sensitivity of the devices and also the constant G relating the output frequency of the light-to-frequency converter chip to the actual band-weighted and field-of-view averaged spectral radiance incident on the detector (brightness). From these parameters, we show how to define a rigorous astronomical absolute photometric system in which the sensor measurements can be reported in units of magnitudes per square arcsecond with precise physical meaning. | |
dc.description.department | Depto. de Física de la Tierra y Astrofísica | |
dc.description.faculty | Fac. de Ciencias Físicas | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | Unión Europea. H2020 | |
dc.description.sponsorship | Ministerio de Ciencia e Innovación (MICINN) | |
dc.description.sponsorship | Comunidad de Madrid | |
dc.description.sponsorship | Xunta de Galicia/FEDER | |
dc.description.sponsorship | Spanish Network for Light Pollution Studies, REECL | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/55635 | |
dc.identifier.doi | 10.3390/s19061336 | |
dc.identifier.issn | 1424-8220 | |
dc.identifier.officialurl | http://dx.doi.org/10.3390/s19061336 | |
dc.identifier.relatedurl | https://www.mdpi.com | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/13359 | |
dc.issue.number | 6 | |
dc.journal.title | Sensors | |
dc.language.iso | eng | |
dc.publisher | MDPI AG | |
dc.relation.projectID | STARS4ALL (688135) | |
dc.relation.projectID | (AYA2015-71542-REDT; AYA2016-75808-R) | |
dc.relation.projectID | TEC2SPACE-CM (P2018/NMT-4291) | |
dc.relation.projectID | ED431B 2017/64 (SB) | |
dc.rights | Atribución 3.0 España | |
dc.rights.accessRights | open access | |
dc.rights.uri | https://creativecommons.org/licenses/by/3.0/es/ | |
dc.subject.cdu | 52 | |
dc.subject.keyword | Light-pollution | |
dc.subject.ucm | Física atmosférica | |
dc.subject.unesco | 2501 Ciencias de la Atmósfera | |
dc.title | Absolute radiometric calibration of TESS-W and SQM night sky brightness sensors | |
dc.type | journal article | |
dc.volume.number | 19 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 949589a4-3398-4ac6-805c-5dcf70d066f2 | |
relation.isAuthorOfPublication.latestForDiscovery | 949589a4-3398-4ac6-805c-5dcf70d066f2 |
Download
Original bundle