Seven-year follow-up of posterior chamber phakic intraocular lens with central port design
dc.contributor.author | Fernández-Vega Cueto, Luis | |
dc.contributor.author | Alfonso Bartolozzi, Belén | |
dc.contributor.author | Lisa Fernández, Carlos | |
dc.contributor.author | Madrid Costa, David | |
dc.contributor.author | Alfonso, José F. | |
dc.date.accessioned | 2023-06-17T09:11:03Z | |
dc.date.available | 2023-06-17T09:11:03Z | |
dc.date.issued | 2021-06-11 | |
dc.description | Received: 22 February 2021 / Accepted: 22 May 2021 / Published: 11 June 2021. | |
dc.description.abstract | Background: To assess the clinical outcomes of the Visian Implantable Collamer Lens (ICL) with a central port throughout 7 years of follow-up. Methods: Eighty-four eyes of 52 patients were evaluated over a follow-up period of 7 years after V4c ICL implantation. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure (IOP), endothelial cell density (ECD) and vault were analysed. Results: The mean postoperative UDVA (logMAR) was 0.04 ± 0.11, 0.13 ± 0.19 and 0.17 ± 0.23 at 1-, 5- and 7-years, respectively (P< 0.0001). The mean CDVA (logMAR) remains unchanged throughout a 7-year follow-up period (0.02 ± 0.08 and 0.02 ± 0.08, at 5- and 7-years, respectively, P= 0.2). At all follow-up visits, more than 95% of the eyes achieved a CDVA of 20/25 or better and more than 85% a CDVA of 20/20. At the end of the follow-up (7 years), no eye lost more lines of CDVA, 56 eyes (66.7%) and 28 eyes (33.3%) gained lines of CDVA. At 7-years, the spherical equivalent was −0.62 ± 0.62 D. No significant increase in IOP (> 20 mmHg or an increase higher than 5 mmHg) occurred in any case throughout the 7-year of follow-up. The loss in ECD from the preoperative baseline at the last follow-up visit was 2.6%. No intraoperative or postoperative complications or adverse events occurred during the follow-up period. Conclusions: The outcomes of this study show the long-term viability of the V4c ICL implantation as a surgical option for the correction of myopia. | |
dc.description.department | Depto. de Optometría y Visión | |
dc.description.faculty | Fac. de Óptica y Optometría | |
dc.description.refereed | TRUE | |
dc.description.sponsorship | STAAR Surgical | |
dc.description.status | pub | |
dc.eprint.id | https://eprints.ucm.es/id/eprint/67503 | |
dc.identifier.doi | 10.1186/s40662-021-00247-1 | |
dc.identifier.issn | 2326-0254 | |
dc.identifier.officialurl | https://doi.org/10.1186/s40662-021-00247-1 | |
dc.identifier.relatedurl | https://eandv.biomedcentral.com/articles/10.1186/s40662-021-00247-1 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14352/8348 | |
dc.issue.number | 23 | |
dc.journal.title | Eye and Vision | |
dc.language.iso | eng | |
dc.page.initial | 9 p. | |
dc.publisher | BMC | |
dc.rights | Atribución 3.0 España | |
dc.rights.accessRights | open access | |
dc.rights.uri | https://creativecommons.org/licenses/by/3.0/es/ | |
dc.subject.cdu | 617.753.2 | |
dc.subject.cdu | 617.7‑089.243 | |
dc.subject.cdu | 681.73 | |
dc.subject.keyword | Implantable Collamer Lens | |
dc.subject.keyword | ICL | |
dc.subject.keyword | Myopia | |
dc.subject.keyword | Long-term | |
dc.subject.ucm | Cirugía | |
dc.subject.ucm | Lentes de contacto | |
dc.subject.ucm | Optometría | |
dc.subject.unesco | 3213 Cirugía | |
dc.subject.unesco | 3311.11 Instrumentos ópticos | |
dc.subject.unesco | 2209.15 Optometría | |
dc.title | Seven-year follow-up of posterior chamber phakic intraocular lens with central port design | |
dc.type | journal article | |
dc.volume.number | 8 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 383ca857-3af5-4787-8717-d278082d1d13 | |
relation.isAuthorOfPublication.latestForDiscovery | 383ca857-3af5-4787-8717-d278082d1d13 |
Download
Original bundle
1 - 1 of 1
Loading...
- Name:
- Fernández-Vega-Cueto2021_Article_Seven-yearFollow-upOfPosterior.pdf
- Size:
- 1.05 MB
- Format:
- Adobe Portable Document Format