Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Electrochemical genosensor for Klotho detection based on aliphatic and aromatic thiols self-assembled monolayers

dc.contributor.authorSánchez-Paniagua López, Marta
dc.contributor.authorPalenzuela Batista, Sara
dc.contributor.authorManzanares Palenzuela, Lorena
dc.contributor.authorLópez Ruiz, María Beatriz
dc.date.accessioned2024-02-08T08:34:04Z
dc.date.available2024-02-08T08:34:04Z
dc.date.issued2020
dc.description.abstractChanges in expression of Klotho gene are associated with chronic kidney disease and its potential as early biomarker is being studied. We report, for the first time, the detection of Klotho gene by a biosensor platform. Self-assembled mixed monolayers (SAMs) as DNA immobilization method in screen-printed gold electrodes and a sandwich format detection were used in the development of an electrochemical genosensor for the detection of a 100-mer DNA fragment, copy of the partial region of the mRNA Klotho gene. The use of different binary and ternary SAMs based on aliphatic (mercaptohexanol, MCH, and hexanedithiol, HDT) and aromatic (mercaptophenylacetic acid, MPAA) thiol diluents and capture probe (CP) as sensing phases was evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. Multiple configurations were studied, changing the order of component addition and comparing co-immobilization and two-step immobilization processes. The procedure for binary SAM preparation consisting of sequential addition of a thiol diluent followed by CP was found to have the least detrimental impact on electrochemical performance. The signal-to-blank ratios increased considerably in the case of thioaromatic binary DNA monolayers, MPPA/CP, compared to the values obtained for aliphatic SAMs. Ternary monolayers formed by MCH and HDT rendered good fractional coverage levels and generated more reversible redox reactions at the surface, mostly when CP was firstly immobilized, CP/HDT/MCH. A significant reduction of the blank and non-specific (non-complementary sequence) signals was obtained with this ternary SAM, compared to binary SAMs and an increase of 2.42-fold of the S/B ratio (10 nM of target) compared with MPAA/CP SAMs. A linear response in the range of 5·10−10 to 5·10−8 M was obtained with CP/HDT/MCH monolayer, with a detection limit of 0.5 nM and RSD of 8.10%.eng
dc.description.departmentDepto. de Química en Ciencias Farmacéuticas
dc.description.facultyFac. de Farmacia
dc.description.refereedTRUE
dc.description.sponsorshipUniversidad Complutense de Madrid
dc.description.sponsorshipBanco Santander
dc.description.statuspub
dc.identifier.citationSánchez-Paniagua M, Palenzuela-Batista S, Manzanares-Palenzuela CL, López-Ruiz B. Electrochemical genosensor for Klotho detection based on aliphatic and aromatic thiols self-assembled monolayers. Talanta 2020;212:120735. https://doi.org/10.1016/j.talanta.2020.120735.
dc.identifier.doi10.1016/j.talanta.2020.120735
dc.identifier.issn0039-9140
dc.identifier.officialurlhttps://doi.org/10.1016/j.talanta.2020.120735
dc.identifier.relatedurlhttps://www.sciencedirect.com/science/article/pii/S0039914020300266?via%3Dihub
dc.identifier.urihttps://hdl.handle.net/20.500.14352/100181
dc.journal.titleTalanta
dc.language.isoeng
dc.relation.projectIDinfo:eu-repo/grantAgreement/PR26/16-20290.
dc.rights.accessRightsrestricted access
dc.subject.cdu543
dc.subject.ucmQuímica analítica (Química)
dc.subject.unesco2301 Química Analítica
dc.titleElectrochemical genosensor for Klotho detection based on aliphatic and aromatic thiols self-assembled monolayers
dc.typejournal article
dc.type.hasVersionAM
dspace.entity.typePublication
relation.isAuthorOfPublication966f7c2f-7001-4961-8820-69b6b96765b5
relation.isAuthorOfPublication82f03299-d29c-41d8-a9ff-c450783e993d
relation.isAuthorOfPublication.latestForDiscovery966f7c2f-7001-4961-8820-69b6b96765b5

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Klotho_Detection.pdf
Size:
1.42 MB
Format:
Adobe Portable Document Format

Collections