| dc.description.abstract | Background Left atrium (LA) size assessment is clinically relevant, but the accuracy of two-dimensional echocardiographic (2D-echo) methods is limited. Three-dimensional (3D) echocardiography is an excellent alternative but is far from being used in daily clinical practice. Three-dimensional-wall motion tracking (3D-WMT) allows us to obtain volumes in a very simple and rapid manner. The aims of this study were to evaluate the accuracy of 3D-WMT technology to assess LA volume using cardiac magnetic resonance (CMR) as a reference method, to evaluate its reproducibility, and to determine its added clinical value to classify the LA enlargement severity. Methods and results Seventy consecutive patients referred for a CMR study were prospectively enrolled. They underwent LA volume assessment by means of 2D-echo, 3D-WMT, and CMR. Inter-methods agreement was assessed. The mean age was 56 ± 18 years and 42 patients (60%) were males. Average maximal LA volume obtained by 2D-echo, 3D-WMT, and CMR were 63.33 ± 26.82, 79.80 ± 29.0, and 79.80 ± 28.99 mL, respectively. Univariate linear regression analysis showed a good correlation between 3D-WMT and CMR (r = 0.83; P < 0.001). The agreement analysis showed a similar result (ICC = 0.83; 95% CI = 0.74–0.89; P < 0.001). Furthermore, the LA enlargement degree was better evaluated with 3D-WMT than with 2D-echo. Conclusion This study validates LA volume measurements obtained using the new and fast 3D-WMT technology, compared with CMR. This method is fast, accurate, and reproducible, and it allows a better classification of left LA enlargement severity compared with 2D-echo. | |
| dc.description.department | Depto. de Medicina | |
| dc.description.faculty | Fac. de Medicina | |
| dc.description.refereed | TRUE | |
| dc.description.status | pub | |
| dc.identifier.citation | Perez de Isla L, Feltes G, Moreno J, Martinez W, Saltijeral A, de Agustin JA, Gomez de Diego JJ, Marcos-Alberca P, Luaces M, Ferreiros J, Garcia Fernandez MA, Macaya C. Quantification of left atrial volumes using three-dimensional wall motion tracking echocardiographic technology: comparison with cardiac magnetic resonance. Eur Heart J Cardiovasc Imaging. 2014 Jul;15(7):793-9. doi: 10.1093/ehjci/jeu001 | |
| dc.identifier.doi | 10.1093/EHJCI/JEU001 | |
| dc.identifier.essn | 2047-2412 | |
| dc.identifier.issn | 2047-2404 | |
| dc.identifier.officialurl | https://doi.org/10.1093/EHJCI/JEU001 | |
| dc.identifier.pmid | 24480243 | |
| dc.identifier.relatedurl | https://academic.oup.com/ehjcimaging/article/15/7/793/2399814 | |
| dc.identifier.relatedurl | https://pubmed.ncbi.nlm.nih.gov/24480243/ | |
| dc.identifier.uri | https://hdl.handle.net/20.500.14352/131923 | |
| dc.issue.number | 7 | |
| dc.journal.title | European Heart Journal Cardiovascular Imaging | |
| dc.language.iso | eng | |
| dc.page.final | 799 | |
| dc.page.initial | 793 | |
| dc.publisher | Oxford Academic | |
| dc.rights.accessRights | restricted access | |
| dc.subject.cdu | 616.12 | |
| dc.subject.keyword | 3D-wall motion tracking | |
| dc.subject.keyword | Cardiac magnetic resonance | |
| dc.subject.keyword | Left atrium | |
| dc.subject.keyword | Three-dimensional echocardiography | |
| dc.subject.ucm | Cardiología | |
| dc.subject.unesco | 3205.01 Cardiología | |
| dc.title | Quantification of left atrial volumes using three-dimensional wallmotion tracking echocardiographic technology: Comparison with cardiacmagnetic resonance | |
| dc.type | journal article | |
| dc.type.hasVersion | VoR | |
| dc.volume.number | 15 | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 395641a3-ea72-4613-a2f3-85fbf86fae29 | |
| relation.isAuthorOfPublication | a4d160b9-b06d-4e03-8aa8-fb88af3fe61b | |
| relation.isAuthorOfPublication | cacd1d83-3ad8-4829-8684-d90aa041927b | |
| relation.isAuthorOfPublication | 3d889115-c522-43c6-973c-9a46af8449e2 | |
| relation.isAuthorOfPublication | 5d7a61fe-bda8-40d7-bbe6-98cf64177dd4 | |
| relation.isAuthorOfPublication | b775562d-8fda-4abe-aaf2-fd622b25a3e8 | |
| relation.isAuthorOfPublication.latestForDiscovery | 395641a3-ea72-4613-a2f3-85fbf86fae29 |
Download
Original bundle
1 - 1 of 1