Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Visual outcomes after progressive apodized diffractive intraocular lens implantation

dc.contributor.authorGarcía-Bella, Javier
dc.contributor.authorVentura-Abreu, Néstor
dc.contributor.authorMorales-Fernández, Laura
dc.contributor.authorTalavero-González, Paula
dc.contributor.authorCarballo Álvarez, Jesús
dc.contributor.authorSanz Fernández, Juan Carlos
dc.contributor.authorVázquez Molini, José María
dc.contributor.authorMartínez De La Casa Fernández-Borrella, José María
dc.date.accessioned2025-01-17T10:30:50Z
dc.date.available2025-01-17T10:30:50Z
dc.date.issued2018-05-01
dc.description.abstractPurpose: To assess photopic and mesopic vision in patients implanted with the Bi-Flex® M 677 MY bifocal intraocular lens (IOL). Methods: In this prospective clinical study, 25 patients with cataract in both eyes were subjected to cataract surgery and bilateral implantation of the Bi-Flex® M 677MY (Medicontur, Hungary) IOL. Three months after surgery, high-contrast photopic uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were determined. Intermediate at 65 cm (DCIVA) and near at 40 cm (DCNVA) visual acuity were also measured, both with best distance correction. The CSV-1000 test chart was used to assess contrast sensitivity (CS). Defocus curves were constructed under photopic and mesopic conditions, determining binocular best-corrected visual acuity over the range +1.50 D to -4.00 D in 0.50-D steps. A KR-1W Wavefront Analyzer was used to measure pupil size and aberrometric outcomes. Presence and type of dysphotopsia were evaluated with the Likert scale. Results: Mesopic mean pupil diameter was 4.58 ± 0.73 mm. The mean values at 3 months were UDVA 0.03 ± 0.09, CDVA -0.05 ± 0.06, DCIVA 0.20 ± 0.07, and DCNVA 0.11 ± 0.08. Mean CS for the 4 frequencies examined were 1.66 ± 0.16, 1.75 ± 0.14, 1.39 ± 0.22, and 0.96 ± 0.19. Significant differences were observed in defocus curves for photopic and mesopic conditions. A significant correlation between pupil diameter and the dysphotopic photopic was found (r = 0.62; p = 0.02). Conclusions: The evaluated progressive apodized diffractive design IOL provides effective restoration of visual function in far and near vision distance with an adequate intermediate visual quality between -1.00 and -1.50 focus.
dc.description.departmentDepto. de Optometría y Visión
dc.description.facultyFac. de Óptica y Optometría
dc.description.refereedTRUE
dc.description.statuspub
dc.identifier.citationGarcia-Bella J, Ventura-Abreu N, Morales-Fernandez L, Talavero-Gonzalez P, Carballo-Alvarez J, Sanz-Fernandez JC, et al. Visual outcomes after progressive apodized diffractive intraocular lens implantation. Eur J Ophthalmol. 2018;28(3):282-6.
dc.identifier.doi10.5301/ejo.5001030
dc.identifier.essn1724-6016
dc.identifier.issn1120-6721
dc.identifier.officialurlhttps://doi.org/10.5301/ejo.5001030
dc.identifier.pmid28967072
dc.identifier.relatedurlhttps://journals.sagepub.com/doi/abs/10.5301/ejo.5001030
dc.identifier.urihttps://hdl.handle.net/20.500.14352/114871
dc.issue.number3
dc.journal.titleEuropean Journal of Ophthalmology
dc.language.isoeng
dc.page.final286
dc.page.initial282
dc.publisherSage Publications
dc.rights.accessRightsopen access
dc.subject.cdu617.7-089.243
dc.subject.cdu681.73
dc.subject.keywordIntraocular lens
dc.subject.keywordProgressived apodized
dc.subject.keywordCataract
dc.subject.keywordVisual function
dc.subject.ucmOftalmología
dc.subject.ucmÓptica oftálmica
dc.subject.ucmCirugía
dc.subject.ucmÓptica y optometría
dc.subject.unesco3201.09 Oftalmología
dc.subject.unesco2209.15 Optometría
dc.subject.unesco3213.09 Cirugía Ocular
dc.subject.unesco3311.09 Lentes
dc.titleVisual outcomes after progressive apodized diffractive intraocular lens implantation
dc.typejournal article
dc.type.hasVersionAM
dc.volume.number28
dspace.entity.typePublication
relation.isAuthorOfPublicationd90c8dc9-5aef-4047-950e-c6c59469ec3f
relation.isAuthorOfPublication5d697408-5fa9-40e3-8a3b-d1ccb049eea6
relation.isAuthorOfPublicationd923f237-b6e7-454f-86c1-2f9556a972c9
relation.isAuthorOfPublication273a99c3-2c9f-4dd0-8939-b7ff3593124c
relation.isAuthorOfPublication.latestForDiscoveryd90c8dc9-5aef-4047-950e-c6c59469ec3f

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Visual_outcomes_progressive_apodized_diffractive_intraocular_lens_implantation.pdf
Size:
718.56 KB
Format:
Adobe Portable Document Format
Description:
Versión preprint del autor

Collections