Aviso: para depositar documentos, por favor, inicia sesión e identifícate con tu cuenta de correo institucional de la UCM con el botón MI CUENTA UCM. No emplees la opción AUTENTICACIÓN CON CONTRASEÑA
 

Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology

dc.contributor.authorPradíes Ramiro, Guillermo Jesús
dc.contributor.authorZarauz, Cristina
dc.contributor.authorValverde, Arelys
dc.contributor.authorFerreiroa Navarro, Alberto
dc.contributor.authorMartínez Rus, Francisco
dc.date.accessioned2023-06-19T13:33:28Z
dc.date.available2023-06-19T13:33:28Z
dc.date.issued2014-12
dc.description.abstractObjective: The aim of this study was to compare the fit of ceramic crowns fabricated from intraoral digital impressions. Methods: Twenty-five participants with 30 posterior teeth with a prosthetic demand were selected for the study. Two crowns were made for each preparation. One crown was fabricated from an intraoral digital impression system (IDI group) and the other crown was fabricated from a conventional two-step silicone impressiom (CI group). To replicate the interface between the crown and the preparation, each crown was cemented on its corresponding clinical preparation with ultra-flow silicone. Each crown was embedded in acrylic resin to stabilise the registered interfase and then cut in 2 mm thick slices in a buco-lingual orientation. The internal gap was determined as the vertical distance from the internal surface of the crown to the prepared tooth surface at four points (marginal gap, axial gap, crest gap, and occlusal fossa gap) using stereomicroscopy with a magnifications of 40x. data was analyzed by using Wilcoxon signed rank test (a=0.05). Results: Internal adaptation values were significantly affected by the impression technique (p=0.001). mean marginal gap was 76.33+-65.32µmfor the crowns of the IDI group and 91.46+-71.17µmfor the CI group. Conclusion: All-ceramic crowns fabricated from intraoral digital impressions with wavefront sampling technology demonstrated better internal fit than crowns manufactured from silicone impressions. Clinical significance:Impressions obtained from an intraoral digital scanner based on wavefront sampling technology can be used for manufacturing ceramic crowns in the normal clinical practice with better results than conventional impressions with elastomers.en
dc.description.departmentDepto. de Odontología Conservadora y Prótesis
dc.description.facultyFac. de Odontología
dc.description.refereedTRUE
dc.description.statuspub
dc.eprint.idhttps://eprints.ucm.es/id/eprint/29683
dc.identifier.doi10.1016/j.jdent.2014.12.007
dc.identifier.issn0300-5712
dc.identifier.officialurlhttps//doi.org/10.1016/j.jdent.2014.12.007
dc.identifier.relatedurlhttp://www.intl.elsevierhealth.com/journals/jden
dc.identifier.urihttps://hdl.handle.net/20.500.14352/34011
dc.issue.number2
dc.journal.titleJournal of dentistry
dc.language.isoeng
dc.page.final208
dc.page.initial201
dc.publisherElsevier
dc.rights.accessRightsopen access
dc.subject.cdu616.314-089.28
dc.subject.keywordAll-ceramic systems
dc.subject.keywordCad-Cam
dc.subject.keywordIntraoral scanner
dc.subject.keywordInternal gap
dc.subject.keywordMarginal gap
dc.subject.keywordZirconia
dc.subject.ucmPrótesis dental
dc.subject.unesco3314.02 Prótesis
dc.titleClinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technologyen
dc.typejournal article
dc.volume.number43
dspace.entity.typePublication
relation.isAuthorOfPublication1f9c3f08-3382-454f-8c0e-b5de6a5d271b
relation.isAuthorOfPublicationf030d94e-3831-4893-8dd4-96421293401b
relation.isAuthorOfPublicationeddef645-1a65-4096-8122-07150050e03c
relation.isAuthorOfPublication.latestForDiscovery1f9c3f08-3382-454f-8c0e-b5de6a5d271b

Download

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
jdent.pdf
Size:
929.05 KB
Format:
Adobe Portable Document Format

Collections